Correlation of gross tumor volume excursion with potential benefits of respiratory gating.

PURPOSE: To test the hypothesis that the magnitude of thoracic tumor motion can be used to determine the desirability of respiratory gating. METHODS AND MATERIALS: Twenty patients to be treated for lung tumors had computed tomography image data sets acquired under assisted breath hold at normal inspiration (100% tidal volume), at full expiration (0% tidal volume), and under free breathing. A radiation oncologist outlined gross tumor volumes (GTVs) on the breath-hold computed tomographic images. These data sets were registered to the free-breathing image data set. Two sets of treatment plans were generated: one based on an internal target volume explicitly formed from assessment of the excursion of the clinical target volume (CTV) through the respiratory cycle, representing an ungated treatment, and the other based on the 0% tidal volume CTV, representing a gated treatment with little margin for residual motion. Dose-volume statistics were correlated to the magnitude of the motion of the center of the GTV during respiration. RESULTS: Patients whose GTVs were >100 cm(3) showed little decrease in lung dose under gating. The other patients showed a correlation between the excursion of the center of the GTV and a reduction in potential lung toxicity. As residual motion increased, the benefits of respiratory gating increased. CONCLUSION: Gating seems to be advantageous for patients whose GTVs are <100 cm(3) and for whom the center of the GTV exhibits significant motion, provided residual motion under gating is kept small.

Humans↗

Evaluation of a contour-alignment technique for CT-guided prostate radiotherapy: an intra- and interobserver study.

PURPOSE: The recent introduction of integrated CT/linear accelerator systems may mean that daily CT localization can become a reality in the clinic, possibly allowing further dose escalation to the prostate while limiting unwanted doses to the rectum and bladder. However, the implementation of CT localization is currently impeded by the lack of precise and robust techniques to align the treatment plan with the daily CT images. The purpose of this study was to evaluate a manual alignment technique, in which the gross target volume contours are overlaid on the daily CT images and then shifted to match the structures visible in the images. METHODS AND MATERIALS: A total of 28 CT image sets were taken before the standard delivery of intensity-modulated radiotherapy for prostate cancer for 2 patients. Seven observers (four radiation oncologists and three medical physicists) manually shifted the gross target volume contours from the treatment plan to best match the daily CT images. One observer repeated the process 1 week later to evaluate intraobserver variations. The experiment was then repeated, but the CT images from the original treatment plan were used as a reference to reduce interobserver uncertainty when aligning the contours. The shifts in prostate position found by different observers, both with and without reference data, were evaluated using a factorial analysis of variance to determine the standard errors of measurement for the intra- and interobserver uncertainty (SEM(intra) and SEM(inter), respectively). The differences in the SEM for the two groups of observers (radiation oncologists and medical physicists), the two alignment techniques (with and without reference information), and the two patients were evaluated using the t test at 90% confidence levels. RESULTS: With no reference information, the SEM(inter) using one patient data set (Patient 1) was 0.8 mm, 2.0 mm, and 2.2 mm in the right-left (RL), anterior-posterior (AP), and superior-inferior (SI) directions, respectively. The use of the treatment plan as a reference reduced the SEM(inter) to 0.7 mm, 1.0 mm, and 1.6 mm in the RL, AP, and SI directions, respectively. In Patient 2, localization of the prostate was more difficult; the best SEM(inter) achieved with this patient was 0.8 mm, 1.9 mm, and 2.0 mm in the RL, AP, and SI directions, respectively. The SEM(intra) values with Patient 1 were also slightly better than with Patient 2. When reference data were used, the SEM(intra) value was 0.5 mm, 0.7 mm, and 0.5 mm for Patient 1 and 0.6 mm, 1.0 mm, and 0.7 mm for Patient 2 in the RL, AP, and SI directions, respectively. Despite the larger than expected interobserver variation reported here, the SEM(inter) was smaller than the typical day-to-day variation in prostate position. The contour alignment technique may still be useful to aid daily prostate localization or in a correction scheme to minimize the effect of target positional error. CONCLUSION: The interobserver uncertainties associated with aligning the gross target volume contours with daily CT images were sufficiently small that this method may be used for daily CT localization of the prostate. The use of a reference image is important to improve the consistency among different users in this technique.

Analysis of Variance↗

Intrafractional tumor motion: lung and liver.

Three-dimensional (3D) dose distribution has been improved by 3D conformation and intensity modulation in external radiotherapy. Interfractional uncertainty has been reduced by image-guided setup techniques. Reduction of ambiguity because of intrafractional target motion is the next step forward. Respiratory organ motion is known to be the largest intrafractional organ motion. Radiotherapy techniques controlling, gating, or tracking respiratory motion are under investigation to use smaller safety margins and higher doses for moving tumors. However, data on intrafractional tumor motion are sparse. We developed a fluoroscopic real-time tracking system and implantation techniques of fiducial markers for moving organs and have been accumulating knowledge about internal tumor motion. We also found the importance of 4-dimensional treatment planning to account for tumor motion in precision radiotherapy. This article reviews the current basic knowledge on respiratory physiology and summarizes the accumulating knowledge on internal motion of lung and liver tumors.

Fluoroscopy↗

Feasibility of insertion/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy.

PURPOSE: To examine the feasibility and reliability of insertion of internal fiducial markers into various organs for precise setup and real-time tumor tracking in radiotherapy (RT). MATERIALS AND METHODS: Equipment and techniques for the insertion of 2.0-mm-diameter gold markers into or near the tumor were developed for spinal/paraspinal lesions, prostate tumors, and liver and lung tumors. Three markers were used to adjust the center of the mass of the target volume to the planned position in spinal/paraspinal lesions and prostate tumors (the three-marker method). The feasibility of the marker insertion and the stability of the position of markers were tested using stopping rules in the clinical protocol (i.e., the procedure was abandoned if 2 of 3 or 3 of 6 patients experienced marker dropping or migration). After the evaluation of the feasibility, the stability of the marker positions was monitored in those patients who entered the dose-escalation study. RESULTS: Each of the following was shown to be feasible: bronchoscopic insertion for the peripheral lung; image-guided transcutaneous insertion for the liver; cystoscopic and image-guided percutaneous insertion for the prostate; and surgical implantation for spinal/paraspinal lesions. Transcutaneous insertion of markers for spinal/paraspinal lesions and bronchoscopic insertion for central lung lesions were abandoned. Overall, marker implantation was successful and was used for real-time tumor tracking in RT in 90 (90%) of 100 lesions. No serious complications related to the marker insertion were noted for any of the 100 lesions. Using three markers surgically implanted into the vertebral bone, the mean +/- standard deviation in distance among the three markers was within 0.2 +/- 0.6 mm (range -1.4 to 0.8) through the treatment period of 30 days. The distance between the three markers gradually decreased during RT in five of six prostate cancers, consistent with a mean rate of volume regression of 9.3% (range 0.015-13%) in 10 days. CONCLUSIONS: Internal 2.0-mm-diameter gold markers can be safely inserted into various organs for real-time tumor tracking in RT using the prescribed equipment and techniques. The three-marker method has been shown to be a useful technique for precise setup for spinal/paraspinal lesions and prostate tumors.

Adenocarcinoma↗

Tumor location, cirrhosis, and surgical history contribute to tumor movement in the liver, as measured during stereotactic irradiation using a real-time tumor-tracking radiotherapy system.

PURPOSE: To investigate the three-dimensional (3D) intrafractional motion of liver tumors during real-time tumor-tracking radiotherapy (RTRT). MATERIALS AND METHODS: The data of 20 patients with liver tumors were analyzed. Before treatment, a 2-mm gold marker was implanted near the tumor. The RTRT system used fluoroscopy image processor units to determine the 3D position of the implanted marker. A linear accelerator was triggered to irradiate the tumor only when the marker was located within a permitted region. The automatically recorded tumor-motion data were analyzed to determine the amplitude of the tumor motion, curve shape of the tumor motion, treatment efficiency, frequency of movement, and hysteresis. Each of the following clinical factors was evaluated to determine its contribution to the amplitude of movement: tumor position, existence of cirrhosis, surgical history, tumor volume, and distance between the isocenter and the marker. RESULTS: The average amplitude of tumor motion in the 20 patients was 4 +/- 4 mm (range 1-12), 9 +/- 5 mm (range 2-19), and 5 +/- 3 mm (range 2-12) in the left-right, craniocaudal, and anterior-posterior (AP) direction, respectively. The tumor motion of the right lobe was significantly larger than that of the left lobe in the left-right and AP directions (p = 0.01). The tumor motion of the patients with liver cirrhosis was significantly larger than that of the patients without liver cirrhosis in the left-right and AP directions (p < 0.004). The tumor motion of the patients who had received partial hepatectomy was significantly smaller than that of the patients who had no history of any operation on the liver in the left-right and AP directions (p < 0.03). Thus, three of the five clinical factors examined (i.e., tumor position in the liver, cirrhosis, and history of surgery on the liver) significantly affected the tumor motion of the liver in the transaxial direction during stereotactic irradiation. Frequency analysis revealed that for 9 (45%) of the 20 tumors, the cardiac beat caused measurable motion. The 3D trajectory of the tumor showed hysteresis for 4 (20%) of the 20 tumors. The average treatment efficiency of RTRT was 40%. CONCLUSIONS: Tumor location, cirrhosis, and history of surgery on the liver all had an impact on the intrafractional tumor motion of the liver in the transaxial direction. This finding should be helpful in determining the smallest possible margin in individual cases of radiotherapy for liver malignancy.

Computer Systems↗

Tolerance of organs at risk in small-volume, hypofractionated, image-guided radiotherapy for primary and metastatic lung cancers.

PURPOSE: To determine the organ at risk and the maximum tolerated dose (MTD) of radiation that could be delivered to lung cancer using small-volume, image-guided radiotherapy (IGRT) using hypofractionated, coplanar, and noncoplanar multiple fields. MATERIALS AND METHODS: Patients with measurable lung cancer (except small-cell lung cancer) 6 cm or less in diameter for whom surgery was not indicated were eligible for this study. Internal target volume was determined using averaged CT under normal breathing, and for patients with large respiratory motion, using two additional CT scans with breath-holding at the expiratory and inspiratory phases in the same table position. Patients were localized at the isocenter after three-dimensional treatment planning. Their setup was corrected by comparing two linacographies that were orthogonal at the isocenter with corresponding digitally reconstructed images. Megavoltage X-rays using noncoplanar multiple static ports or arcs were used to cover the parenchymal tumor mass. Prophylactic nodal irradiation was not performed. The radiation dose was started at 60 Gy in 8 fractions over 2 weeks (60 Gy/8 Fr/2 weeks) for peripheral lesions 3.0 cm or less, and at 48 Gy/8 Fr/2 weeks at the isocenter for central lesions or tumors more than 3.0 cm at their greatest dimension. RESULTS: Fifty-seven lesions in 45 patients were treated. Tumor size ranged from 0.6 to 6.0 cm, with a median of 2.6 cm. Using the starting dose, 1 patient with a central lesion died of a radiation-induced ulcer in the esophagus after receiving 48 Gy/8 Fr at isocenter. Although the contour of esophagus received 80% or less of the prescribed dose in the planning, recontouring of esophagus in retrospective review revealed that 1 cc of esophagus might have received 42.5 Gy, with the maximum dose of 50.5 Gy. One patient with a peripheral lesion experienced Grade 2 pain at the internal chest wall or visceral pleura after receiving 54 Gy/8 Fr. No adverse respiratory reaction was noted in the symptoms or respiratory function tests. The 3-year local control rate was 80.4% +/- 7.1% (a standard error) with a median follow-up period of 17 months for survivors. Because of the Grade 5 toxicity, we have halted this Phase I/II study and are planning to rearrange the protocol setting accordingly. The 3-year local control rate was 69.6 +/- 10.6% for patients who received 48 Gy and 100% for patients who received 60 Gy (p = 0.0442). CONCLUSIONS: Small-volume IGRT using 60 Gy in eight fractions is highly effective for the local control of lung tumors, but MTD has not been determined in this study. The organs at risk are extrapleural organs such as the esophagus and internal chest wall/visceral pleura rather than the pulmonary parenchyma in the present protocol setting. Consideration of the uncertainty in the contouring of normal structures is critically important, as is uncertainty in setup of patients and internal organ in the high-dose hypofractionated IGRT.

Adult↗

[Comparison of imaging modalities for image-guided radiation therapy (IGRT)].

The use of a new integrated CT/LINAC combination, in which the CT scanner is inside the treatment room, and the same patient couch is used for CT scanning and treatment, should allow for accurate and precise correction of interfractional set-up errors. Comparison of intentional shifts in phantom position as detected by the CT system with shifts detected by an ultrasound localization device commonly used for prostate localization, and by an electronic portal imaging device, showed the standard deviation of set-up uncertainties to be within 1 mm in all directions for each modality. The agreement between the modalities was within 2.6 mm, 1.6 mm and 1.7 mm in the superior-inferior (SI), anterior-posterior (AP) and right-left (RL) directions, respectively. All these modalities are, therefore, suitable for image-guided radiation therapy applications. The choice of modality can be made based of factors such as anatomical site, inter-user variations, and patient set-up.

Humans↗

Small-volume image-guided radiotherapy using hypofractionated, coplanar, and noncoplanar multiple fields for patients with inoperable Stage I nonsmall cell lung carcinomas.

BACKGROUND: Occasionally, medically compromised and/or elderly patients with nonsmall cell lung carcinomas (NSCLCs) cannot be treated surgically. We investigated small-volume hypofractionated image-guided radiotherapy (IGRT) without the need for breath control in patients with inoperable Stage I NSCLCs. METHODS: Between September 1996 and September 1999, 22 patients with Stage I NSCLCs, including 19 males and 3 females, were treated with IGRT. Among these patients, there were 13 Stage IA and 9 Stage IB tumors. The tumors ranged in size from 14.2 to 58.5 mm, with a median size of 26.7 mm. Of the 22 patients, 19 were unfit for surgical treatment due to poor pulmonary function, complications, and/or advanced age and 3 refused surgery. Computed tomographic scans (CT) of the primary tumor were taken during three respiratory phases and they were analyzed to determine the planning target volume, which included only the primary tumor with allowances for respiratory movement. The radiation doses administered at the edge of the moving tumor during normal breathing were 80% of the prescribed dose, either 48 or 60 Gy given in eight fractions over 2 weeks. Clinical evaluation, chest CT scan, and pulmonary function tests were performed before irradiation and at regular intervals for the post-IGRT follow-up. The median follow-up period was 24 months (range, 2-44 months; mean, 21.8 months) (at least 24 months for survivors). RESULTS: Of 17 tumors assessed at the initial follow-up 2-6 months after treatment (5 complete responses, 11 partial responses, and 1 progressive disease), 16 (94%) were controlled locally. One local recurrence was observed during the follow-up. The lung carcinoma-specific survival rate at 1 year was 94% and the 1-year actuarial recurrence-free survival rate was 71%. The lung carcinoma-specific survival rate at 2 years was 73% and the 2-year actuarial recurrence-free survival rate was 67%. The treatment was well tolerated and no major side effects were observed. Localized radiation pneumonitis was observed in all patients who were examined by CT scan, but the patients were asymptomatic. Parameters of pulmonary function, including vital capacity, total lung capacity, and diffusion capacity for carbon monoxide, decreased very little or not at all, indicating that IGRT rarely deteriorated pulmonary functions. CONCLUSIONS: Small-volume hypofractionated IGRT without breath control is a feasible and beneficial method for the curative treatment of patients with Stage I NSCLCs. It has the potential of a high local tumor control rate and low morbidity.

Aged↗

Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions.

PURPOSE: To quantify three-dimensional (3D) movement of the prostate gland with the patient in the supine and prone positions and to analyze the movement frequency for each treatment position. METHODS AND MATERIALS: The real-time tumor-tracking radiotherapy (RTRT) system was developed to identify the 3D position of a 2-mm gold marker implanted in the prostate 30 times/s using two sets of fluoroscopic images. The linear accelerator was triggered to irradiate the tumor only when the gold marker was located within the region of the planned coordinates relative to the isocenter. Ten patients with prostate cancer treated with RTRT were the subjects of this study. The coordinates of the gold marker were recorded every 0.033 s during RTRT in the supine treatment position for 2 min. The patient was then moved to the prone position, and the marker was tracked for 2 min to acquire data regarding movement in this position. Measurements were taken 5 times for each patient (once a week); a total of 50 sets for the 10 patients was analyzed. The raw data from the RTRT system were filtered to reduce system noise, and the amplitude of movement was then calculated. The discrete Fourier transform of the unfiltered data was performed for the frequency analysis of prostate movement. RESULTS: No apparent difference in movement was found among individuals. The amplitude of 3D movement was 0.1-2.7 mm in the supine and 0.4-24 mm in the prone positions. The amplitude in the supine position was statistically smaller in all directions than that in the prone position (p < 0.0001). The amplitude in the craniocaudal and AP directions was larger than in the left-right direction in the prone position (p < 0.0001). No characteristic movement frequency was detected in the supine position. The respiratory frequency was detected for all patients regarding movement in the craniocaudal and AP directions in the prone position. The results of the frequency analysis suggest that prostate movement is affected by the respiratory cycle and is influenced by bowel movement in the prone position. CONCLUSION: The results of this study have confirmed that internal organ motion is less frequent in the supine position than in the prone position in the treatment of prostate cancer. RTRT would be useful in reducing uncertainty due to the effects of the respiratory cycle, especially in the prone position.

Fluoroscopy↗

Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy.

PURPOSE: In this work, three-dimensional (3D) motion of lung tumors during radiotherapy in real time was investigated. Understanding the behavior of tumor motion in lung tissue to model tumor movement is necessary for accurate (gated or breath-hold) radiotherapy or CT scanning. METHODS: Twenty patients were included in this study. Before treatment, a 2-mm gold marker was implanted in or near the tumor. A real-time tumor tracking system using two fluoroscopy image processor units was installed in the treatment room. The 3D position of the implanted gold marker was determined by using real-time pattern recognition and a calibrated projection geometry. The linear accelerator was triggered to irradiate the tumor only when the gold marker was located within a certain volume. The system provided the coordinates of the gold marker during beam-on and beam-off time in all directions simultaneously, at a sample rate of 30 images per second. The recorded tumor motion was analyzed in terms of the amplitude and curvature of the tumor motion in three directions, the differences in breathing level during treatment, hysteresis (the difference between the inhalation and exhalation trajectory of the tumor), and the amplitude of tumor motion induced by cardiac motion. RESULTS: The average amplitude of the tumor motion was greatest (12 +/- 2 mm [SD]) in the cranial-caudal direction for tumors situated in the lower lobes and not attached to rigid structures such as the chest wall or vertebrae. For the lateral and anterior-posterior directions, tumor motion was small both for upper- and lower-lobe tumors (2 +/- 1 mm). The time-averaged tumor position was closer to the exhale position, because the tumor spent more time in the exhalation than in the inhalation phase. The tumor motion was modeled as a sinusoidal movement with varying asymmetry. The tumor position in the exhale phase was more stable than the tumor position in the inhale phase during individual treatment fields. However, in many patients, shifts in the exhale tumor position were observed intra- and interfractionally. These shifts are the result of patient relaxation, gravity (posterior direction), setup errors, and/or patient movement.The 3D trajectory of the tumor showed hysteresis for 10 of the 21 tumors, which ranged from 1 to 5 mm. The extent of hysteresis and the amplitude of the tumor motion remained fairly constant during the entire treatment. Changes in shape of the trajectory of the tumor were observed between subsequent treatment days for only one patient. Fourier analysis revealed that for 7 of the 21 tumors, a measurable motion in the range 1-4 mm was caused by the cardiac beat. These tumors were located near the heart or attached to the aortic arch. The motion due to the heartbeat was greatest in the lateral direction. Tumor motion due to hysteresis and heartbeat can lower treatment efficiency in real-time tumor tracking-gated treatments or lead to a geographic miss in conventional or active breathing controlled treatments. CONCLUSION: The real-time tumor tracking system measured the tumor position in all three directions simultaneously, at a sampling rate that enabled detection of tumor motion due to heartbeat as well as hysteresis. Tumor motion and hysteresis could be modeled with an asymmetric function with varying asymmetry. Tumor motion due to breathing was greatest in the cranial-caudal direction for lower-lobe unfixed tumors.

Adenocarcinoma↗

Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT).

BACKGROUND AND PURPOSE: We have developed a linear accelerator synchronized with a fluoroscopic real-time tumor-tracking system to reduce errors due to setup and organ motion. In the real-time tumor-tracking radiation therapy (RTRT) system, the accuracy of tumor tracking depends on the registration of the marker's coordinates. The registration accuracy and possible migration of the internal fiducial gold marker implanted into prostate and liver was investigated. MATERIALS AND METHODS: Internal fiducial gold markers were implanted in 14 patients with prostate cancer and four patients with liver tumors. Computed tomography (CT) was carried out as a part of treatment planning in the 18 patients. A total of 72 follow-up CT scans were taken. We calculated the relative relationship between the coordinates of the center of mass (CM) of the organs and those of the marker. The discrepancy in the CM coordinates during a follow-up CT compared to those recorded during the planning CT was used to study possible marker migration. RESULTS: The standard deviation (SD) of interobserver variations in the CM coordinates was within 2.0 and 0.4 mm for the organ and the marker, respectively, in seven observers. Assuming that organs do not shrink, grow, or rotate, the maximum SD of migration error in each direction was estimated to be less than 2.5 and 2.0 mm for liver and prostate, respectively. There was no correlation between the marker position and the time after implantation. CONCLUSION: The degree of possible migration of the internal fiducial marker was within the limits of accuracy of the CT measurement. Most of the marker movement can be attributed to the measurement uncertainty, which also influences registration in actual treatment planning. Thus, even with the gold marker and RTRT system, a planning target volume margin should be used to account for registration uncertainty.

Carcinoma, Hepatocellular↗

[Gated Radiotherapy]

Recent external radiotherapy requires precise localization of the target because advance in diagnostic imaging has made it possible to visualize a tiny tumor which would be curable with focused high dose irradiation. However, tumors in respiratory and bowel organs have been difficult to be given the high dose because of 1 to 3 cm movement during delivery of irradiation. Respiratory-gating techniques have been used with medical linear accelerators and particle therapy machines. Real-time tumor-tracking radiotherapy has been realized using fluoroscopic x-rays, internal gold-markers, and pattern recognition technology. Advantage and disadvantage of each gating technique have been realized. Active breath control method would be a cost-effective way of precise treatment without gating. More work is required to find the relationship between abdominal wall and internal movement of the tumor in many respiratory-gating radiotherapy and between the internal markers and target volume in real-time tracking radiotherapy.

Journal Article↗

Reduction in acute morbidity using hypofractionated intensity-modulated radiation therapy assisted with a fluoroscopic real-time tumor-tracking system for prostate cancer: preliminary results of a phase I/II study.

PURPOSE: The positioning of the prostate is improved with the use of the fluoroscopic real-time tumor-tracking radiation therapy system for prostate cancer. The acute radiation reaction and preliminary tumor response of prostate cancer to hypofractionated intensity-modulated radiation therapy assisted with real-time tumor-tracking radiation therapy were investigated in this study. METHODS: Patients were classified into prognostic risk groups on the basis of the presence of the pretreatment prostate-specific antigen, clinical stage, and histologic differentiation. Neoadjuvant hormonal therapy was administered to patients in the high-risk group for 6 months before radiation therapy commenced. The intensity-modulated radiation therapy employed a segmental multileaf collimator, which generated a field made up of two or more shaped subfields using forward planning. Real-time tumor-tracking radiation therapy was used for the precise positioning of the prostate to minimize geometric uncertainties, while the dose was escalated in increments of 5 Gy from 65 Gy using a daily dose of 2.5 Gy (65 Gy/2.5 Gy), following the dose-escalation rules. Acute and late gastrointestinal and genitourinary morbidities due to radiation therapy were scored according to the toxicity criteria of Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer. RESULTS: Thirty-one patients were enrolled in this study between 1998 and 2001. Eighteen patients were classified as being members of the high-risk group. Total dose was escalated, with 65 Gy/2.5 Gy being administered to 12 patients and 70 Gy/2.5 Gy to 19 patients. The median follow-up period was 37 months (range, 30-43 months), and 19 months (range, 10-27 months), for the 65-Gy and 70-Gy arms, respectively. Patients experienced no acute toxicity and grade 1 late gastrointestinal toxicity (8.3%) in the 65-Gy/2.5-Gy arm. Patients in the 70-Gy/2.5-Gy arm experienced grade 1 acute gastrointestinal toxicity (5.3%) and grade 1 and 2 acute genitourinarytoxicities (15.8%). No patients experienced dose-limiting toxicity (defined as a grade 3 or higher acute toxicity) or a grade 2 or higher late complication in this study period. One and two prostate-specific antigen relapses were observed in the 65-Gy and 70-Gy arms, respectively. CONCLUSION: Up to 70 Gy/2.5 Gy, equivalent to 80 Gy with a daily dose of 2.0 Gy, assuming alpha/beta ratio of 1.5, intensity-modulated radiation therapy assisted with real-time tumor-tracking radiation therapy was administered safely with a reasonable biochemical control rate. A further dose-escalation study using this system is justifiable.

Acute Disease↗