Effect of alumina femoral head on clinical results in cemented total hip arthroplasty: old versus current alumina.

BACKGROUND: The wear rate of polyethylene against alumina was demonstrated to be lower than against metal, and the results of early clinical studies of alumina-on-polyethylene combination were as good as expected, but the long-term results of alumina ceramic heads were not as good, as reported by several authors. The purpose of this study was to assess the clinical results over 10 years of cemented total hip arthroplasty (THA) with two types of alumina head: old and current alumina. METHODS: We compared the clinical results of these two types of alumina used for cemented THA. The first type was old alumina (containing 7% yttria), and 77 hips with a 28-mm head (group I) were included. The second type was current alumina (highly purified alumina), and 50 hips with a 26-mm head (group II) and 88 hips with a 22-mm head (group III) were included. The mean follow-up was 17 years 4 months in group I, 12 years 3 months in group II, and 10 years in group III. RESULTS: The Kaplan-Meier survival analysis, with revision for any reason as the endpoint, predicted 10-year survival rates of 90.8%, 100%, and 97.5% for groups I, II, and III, respectively. The survival curves differed significantly only between groups I and II. The probabilities of 10-year survival of the pros-theses with radiological loosening as the endpoint were 77.2%, 91.6%, and 96.5%, respectively. The survival curves showed significant differences only between groups II and III. CONCLUSIONS: The old alumina showed a higher wear rate and rougher surface on the femoral head than did the current alumina in our previous study. The clinical results also indicated superiority of current alumina over old alumina. The difference in the size of the femoral head (26 vs. 22 mm) did not affect the clinical results.

Adult↗

In vivo aging test for a bioactive bone cement consisting of glass bead filler and PMMA matrix.

The degradation of a new bioactive bone cement (GBC), comprised of an inorganic filler (bioactive MgO-CaO-SiO(2)-P(2)O(5)-CaF(2) glass beads) and an organic matrix [high-molecular-weight polymethyl methacrylate (PMMA)], was evaluated in an in vivo aging test. Hardened rectangular specimens (20 x 4 x 3 mm) were prepared from two GBC formulations (containing 50% w/w [GBC50] or 60% w/w [GBC60] bioactive beads) and a conventional PMMA bone cement control (CMW-1). Initial bending strengths were measured with the use of the three-point bending method. Specimens of all three cements were then implanted into the dorsal subcutaneous tissue of rats, removed after 3, 6, or 12 months, and tested for bending strength. The bending strengths (MPa) of GBC50 at baseline (0 months), 3, 6, and 12 months were 136 +/- 1, 119 +/- 3, 106 +/- 5 and 104 +/- 5, respectively. Corresponding values were 138 +/- 3, 120 +/- 3, 110 +/- 2 and 109 +/- 5 for GBC60, and 106 +/- 5, 97 +/- 5, 92 +/- 4 and 88 +/- 4 for CMW-1. Although the bending strengths of all three cements decreased significantly from 0 to 6 months, those of GBC50 and GBC60 did not change significantly thereafter, whereas that of CMW-1 declined significantly between 6 and 12 months. Thus, degradation of GBC50 and GBC60 does not appear to continue after 6 months, whereas CMW-1 degrades progressively over 12 months. Moreover, the bending strengths of GBC50 and GBC60 (especially GBC60) were significantly higher than that of CMW-1 throughout. It is believed that GBC60 is strong enough for use under weight-bearing conditions and that its mechanical strength is retained in vivo; however, its dynamic fatigue behavior will need assessment before application in the clinical setting.

Animals↗

Displacement of a cemented socket after reduction of a dislocated total hip arthroplasty.

Acute displacement of the cemented acetabular component of a hip arthroplasty after attempted reduction of a dislocation is described. The causes of displacement of the socket, which was not radiologically loose, are discussed. Potential causes include impingement of the femoral head and the ceramic screw head overhanging the acetabular bone, which was used to fix the bone graft.

Aged↗

Micro-wear features on unique 100-Mrad cups: two retrieved cups compared to hip simulator wear study.

We studied the micro-wear phenomena of unique, extensively cross-linked polyethylene cups (cross-linked with 1,000 kGy-irradiation) that had been used briefly in Japan. Two retrievals (at 15 years) came from the Japanese "SOM" hip system (implanted 1971-78). These were compared to a set of 0 kGy and 500-1,500 kGy cups run in our hip simulator. The polyethylene cups that had not been cross-linked had the greatest wear. The worn areas had a burnished appearance and were clearly separated from the unworn region by a distinct ridge-line. The worn areas had lost all machine tracks, showed a large amount of UHMWPE 'flow', and long PE fibrils. The associated surface rippling was degraded. These features were considered synonymous with severe polyethylene wear. In contrast, the worn areas in the very cross-linked cups had a visibly matte surface and no ridge-line. Micro-examination showed that the machine tracks were still present. Ripple formations were less obvious than in the cups that were not cross-linked, polyethylene surface fibrils were scarcer and all the fibrils were much smaller than in the cups that were not crosslinked. Our two retrieved cups and the simulator cups confirmed the greater wear-resistance of very cross-linked polyethylene. It should also be noted that the SOM cup design and processing were unique and differed greatly from that of modern polyethylene cups.

Biocompatible Materials↗

Phase stability after aging and its influence on pin-on-disk wear properties of Ce-TZP/Al2O3 nanocomposite and conventional Y-TZP.

Recently zirconia/alumina composites have been examined by many researchers as the new generation of bearing materials in total joint replacements. In this study, the phase stability of a Ce-TZP/Al(2)O(3) nanocomposite and conventional Y-TZP after aging, and its influence on wear resistance, were investigated. Very slight phase transformation was observed in both types of ceramics 18 months after the implantation of Ce-TZP/Al(2)O(3) or Y-TZP samples into rabbit tibiae. However, Y-TZP showed marked phase transformation (approximately 80%) after aging in an autoclave (121 degrees C) for 190 h or in physiological saline at 62 degrees C for 18 months, whereas the new composite remained almost resistant to degradation. According to the results of self-pairing pin-on-disk wear tests using ceramic specimens with or without autoclave aging, the wear factor was almost the same between Ce-TZP/Al(2)O(3) samples with and without aging (6.74 +/- 0.36 x 10(-8) and 6.04 +/- 0.95 x 10(-8) mm(3)/Nm, respectively). In contrast, although non-aged Y-TZP had the lowest wear factor (4.88 +/- 0.51 x 10(-8) mm(3)/Nm) of all specimens tested, aged Y-TZP showed 10-fold greater wear than nonaged Y-TZP. The present study suggests that Ce-TZP/Al(2)O(3) nanocomposite has much greater phase stability than Y-TZP, and that its wear properties are not influenced by aging.

Aluminum Oxide↗

Wear mode and wear mechanism of retrieved acetabular cups.

Nineteen ultra-high-molecular-weighted polyethylene (UHMWPE) cups were retrieved at revision surgery. The implant period was on average 9.9 (0.25-20.7) years. The cups were classified into the high-wear group (wear rate above 140 mm(3)/year), intermediate-wear group (wear rate 80-140 mm(3)/year) and low-wear group (wear rate below 80 mm(3)/year). The wear rate was measured by a fluid displacement method. The cups were studied using scanning electron microscopy. Ripples mainly appeared on the cups in the low-wear group, and nodules and fibrils mainly appeared in the high-wear group. Folding was observed in all cups, but folding with numerous fibrils was conspicuous in the high-wear group. The cup retrieved at 3 months already exhibited folding. From these results, the wear response appeared to be a three-step process: (1) foldings are generated, (2) ripples are formed on the surface, and (3) fibrils are produced from the surface and delaminated, leading to the formation of wear debris.

Adult↗

PMMA-based bioactive cement: effect of CaF2 on osteoconductivity and histological change with time.

A new bioactive bone cement (designated GBC), which is a polymethyl methacrylate- (PMMA-) based composite consisting of bioactive glass beads as an inorganic filler and high-molecular-weight PMMA (hPMMA) as an organic matrix, has been developed. The bioactive glass beads consist of MgO-CaO-SiO(2)-P(2)O(5)-CaF(2) glass. The purpose of the present study was to evaluate the effect of CaF(2) on osteoconductivity and to evaluate the degree of cement degradation with time. Three different types of cement were prepared. GBC(F +), which has been previously described, consisted of CaF(2)-containing bioactive glass beads and hPMMA. GBC(F -) consisted of CaF(2)-free bioactive glass beads and hPMMA. The third cement was hPMMA itself (as a reference material). These three types of cement were packed into the intramedullary canals of rat tibiae to evaluate osteoconductivity, as determined by an affinity index calculated as the length of bone in direct contact with the cement surface expressed as a percentage of the total length of the cement surface. Rats were killed at 4, 8, 25, and 52 weeks after implantation, and the affinity index was calculated for each type of cement at each time point. Histologically, new bone had formed along the surface of both GBC(F +) and GBC(F -) within 4 weeks, whereas hPMMA had little contact with bone, and an intervening soft tissue layer between bone and cement was detected. No significant difference in affinity index was found between GBC(F +) and GBC(F -) at any of the time points studied, although GBC(F -) showed higher affinity indices than GBC(F +) at 8, 25, and 52 weeks. The affinity indices for GBC(F +) and GBC(F -) were significantly higher than those for hPMMA at all time points. With GBC(F +) and GBC(F -), significant increases in the affinity indices were found as the implantation period increased, and the affinity index values at 52 weeks reached more than 70%. In hPMMA, no significant increase in affinity index was observed up to 52 weeks, and the value at 52 weeks was less than 30%. Although no significant difference in affinity index was found between GBC(F +) and GBC(F -), GBC(F -) is conclusively better than GBC(F +) because diseases such as chronic fluorosis might be caused by CaF(2)-containing glass beads. Regarding the cement degradation of both GBC(F +) and GBC(F -), the degree of the degradation at 25 weeks was the same as that at 52 weeks. Therefore, the cement degradation does not appear to proceed rapidly. Further studies are needed to better understand the degradation process.

Animals↗

Interfacial tensile strength between polymethylmethacrylate-based bioactive bone cements and bone.

We have developed two types of polymethylmethacrylate (PMMA)-based bioactive bone cements containing bioactive glass beads (designated GBC) or apatite-wollastonite containing glass-ceramic powder (designated AWC) as the filler. A new method was used to evaluate the bone-cement interfacial strength of these bioactive bone cements. Two types of bioactive bone cements (GBC and AWC) and PMMA cement (CMW-1) were put in a frame attached to the smooth tibial metaphyseal cortex of the rabbit and polymerized in situ. The load required to detach the cement from the bone was measured at 4, 8, and 16 weeks after implantation. The interfacial tensile strength of GBC and AWC showed significantly higher values than PMMA cement from 4 weeks, and increased with time. For GBC, strength reached a maximum value of 12.39 +/- 1.79 kgf 16 weeks after implantation. Histological examination of rabbit tibiae up to 16 weeks demonstrated no intervening layer between the bioactive bone cements and the bone, whereas fibrous tissue was observed at the interface between the PMMA cement and the bone. From this study, we conclude that PMMA-based bioactive bone cements have a relatively higher adhesiveness at the interface than the conventionally used PMMA cement, showing potential as a promising alternative.

Animals↗

Micro-wear patterns on UHMWPE tibial inserts in total knee joint simulation.

The objective of this study was to examine both simulator and retrieved total knee replacement polyethylene inserts to confirm, using scanning electron microscopy, whether similar micro-wear patterns to those seen on retrieved inserts were reproduced on simulator specimens. The simulator specimens consisted of samples subjected to sliding and rolling movement (Experiment 1) and to sliding movement only (Experiment 2). Samples from Experiment 1 demonstrated longitudinal patterns in the middle of the wear track and transverse patterns in the anterior and posterior ends, whereas in Experiment 2, only transverse patterns were observed. In the retrieved specimens, both longitudinal and transverse patterns were observed. The results showed that the simulator study reproduced similar patterns of micro-damage on polyethylene, and that the longitudinal micro-wear pattern was related to the rolling movement that is distinctive in knee kinematics.

Biomechanical Phenomena↗

Ce-TZP/Al2O3 nanocomposite as a bearing material in total joint replacement.

The objectives of this study were to investigate the biocompatibility, phase stability, and wear properties of a newly developed Ce-TZP/Al(2)O(3) nanocomposite, as compared to conventional ceramics, and to determine whether the new composite could be used as a bearing material in total joint prostheses. In tests of mechanical properties, this composite showed significantly higher toughness than conventional Y-TZP. For biocompatibility tests, cylindrical specimens of both the Ce-TZP/Al(2)O(3) nanocomposite and monolithic alumina were implanted into the paraspinal muscles of male Wistar rats. The tissue reactions were almost the same, and at 24 weeks after implantation, thin fibrous capsules with almost no inflammation were observed around both of them. There were no significant differences in membrane thickness between the two ceramics. After hydrothermal treatment in 121 degrees C vapor for 18 h, the new composite showed complete resistance to aging degradation, whereas Y-TZP showed a phase transformation of 25.3 vol% (initial 0.4%) to the monoclinic form. According to the results of pin-on-disk tests, the wear rates of Ce-TZP/Al(2)O(3) nanocomposite and alumina were 0.55 +/- 0.04 x 10(-7) and 2.12 +/- 0.37 x 10(-7)mm(3)/Nm, respectively. The results of this study suggest that the Ce-TZP/Al(2)O(3) nanocomposite is a promising alternative ceramic component for total joint replacement.

Aluminum Oxide↗