PubMed Health⌕ Search

Biomedical subjects

Keith D Paulsen

Publications and source records attributed to Keith D Paulsen.

At least 19 recordsLinked to original sources

Spectrally resolved bioluminescence optical tomography.

Spectrally resolved bioluminescence optical tomography is an approach to recover images of luciferase activity within a volume using multiwavelength emission data from internal bioluminescence sources. The underlying problem of uniqueness associated with nonspectrally resolved intensity-based bioluminescence tomography is highlighted. Reconstructed images of bioluminescence are presented by using as input both simulated and real multiwavelength data from a tissue-simulating phantom. The location of the internal bioluminescence is obtained with 1 mm accuracy. Further, the amplitude of the reconstructed source is proportional to the actual bioluminescence intensity.

Imaging, Three-Dimensional↗

In vivo hemoglobin and water concentrations, oxygen saturation, and scattering estimates from near-infrared breast tomography using spectral reconstruction.

RATIONALE AND OBJECTIVES: Near-infrared (NIR) imaging has its niche in quantifying and characterizing functional changes in tissue relating to vascularity and metabolic status. Here, NIR tomography was applied to study mammographically normal breast tissue in vivo by evaluating relationships between functional parameters so obtained to clinical representers in an effort to understand factors influencing tissue compositional changes. MATERIALS AND METHODS: A new spectral reconstruction method that is considered to provide the most accurate estimates of hemoglobin level, oxygen saturation, water fraction, scattering power, and amplitude was used to assess healthy breast tissue imaged in vivo by means of NIR tomography. The approach directly recovers functional parameters with inherent inclusion of spectral behavior enforced through the incorporation of a priori model assumptions. Sixty subjects were imaged by using a frequency-domain instrument followed by spectral image reconstruction and statistical analysis for significant correlations. RESULTS: The new analysis shows statistically significant inverse correlations between body mass index and breast total hemoglobin and water fractions. Water fraction also correlated inversely with age and separated certain categories of breast density. Average scatter power was indicative of breast radiographic density composition, whereas scatter amplitude varied inversely with breast diameter. Total hemoglobin correlated with water fraction, whereas water correlated with scatter power. CONCLUSION: The changes observed here are attributable to volume fraction alterations and provide some of the most comprehensive data on breast composition variations with demographic factors.

Adult↗

Finite element implementation of Maxwell's equations for image reconstruction in electrical impedance tomography.

Traditionally, image reconstruction in electrical impedance tomography (EIT) has been based on Laplace's equation. However, at high frequencies the coupling between electric and magnetic fields requires solution of the full Maxwell equations. In this paper, a formulation is presented in terms of the Maxwell equations expressed in scalar and vector potentials. The approach leads to boundary conditions that naturally align with the quantities measured by EIT instrumentation. A two-dimensional implementation for image reconstruction from EIT data is realized. The effect of frequency on the field distribution is illustrated using the high-frequency model and is compared with Laplace solutions. Numerical simulations and experimental results are also presented to illustrate image reconstruction over a range of frequencies using the new implementation. The results show that scalar/vector potential reconstruction produces images which are essentially indistinguishable from a Laplace algorithm for frequencies below 1 MHz but superior at frequencies reaching 10 MHz.

Algorithms↗

Spectral priors improve near-infrared diffuse tomography more than spatial priors.

We compare the benefits of spatial and spectral priors in near-infrared diffuse tomography image reconstruction. Although previous studies that incorporated anatomical spatial priors have shown improvement in algorithm convergence and resolution, our results indicate that functional parameter quantification by this approach can be suboptimal. The incorporation of a priori spectral information significantly improves the accuracy observed in recovered images. Specifically, phantom results show that the maximum total hemoglobin concentration ([Hb(T)]) in a region of heterogeneity reached 91% of the true value compared to 63% using spatial priors. The combination of both priors produced results accurate to 98% of the true [Hb(T)]. When both spatial and spectral priors were applied in a healthy volunteer, glandular tissue showed a higher [Hb(T)], water fraction, and scattering power compared to adipose tissue.

Algorithms↗

Multiepitope HER2 targeting enhances photoimmunotherapy of HER2-overexpressing cancer cells with pyropheophorbide-a immunoconjugates.

Multi-targeting strategies improve the efficacy of antibody and immunotoxin therapies but have not yet been thoroughly explored for HER2-based cancer treatments. We investigated multi-epitope HER2 targeting to boost photosensitizer immunoconjugate uptake as a way of enhancing photoimmunotherapy. Photoimmunotherapy may allow targeted photodynamic destruction of malignancies and may also potentiate anticancer antibodies. However, one obstacle preventing its clinical use is the delivery of enough photosensitizer immunoconjugates to target cells. Anti-HER2 photosensitizer immunoconjugates were constructed from two monoclonal antibodies (mAb), HER50 and HER66, using a novel method originally developed to label photosensitizer immunoconjugates with the photosensitizer, benzoporphyrin derivative verteporfin. Photosensitizer immunoconjugates were labeled instead with a promising alternative photosensitizer, pyropheophorbide-a (PPa), which required only minor changes to the conjugation procedure. Uptake and phototoxicity experiments using human cancer cells were conducted with the photosensitizer immunoconjugates and, for comparison, with free PPa. SK-BR-3 and SK-OV-3 cells served as HER2-overexpressing target cells. MDA-MB-468 cells served as HER2-nonexpressing control cells. Photosensitizer immunoconjugates with PPa/mAb molar ratios up to approximately 10 specifically targeted and photodynamically killed HER2-overexpressing cells. On a per mole basis, photosensitizer immunoconjugates were less phototoxic than free PPa, but photosensitizer immunoconjugates were selective for target cells whereas free PPa was not. Multiepitope targeted photoimmunotherapy with a HER50 and HER66 photosensitizer immunoconjugate mixture was significantly more effective than single-epitope targeted photoimmunotherapy with a single anti-HER2 photosensitizer immunoconjugate, provided photosensitizer immunoconjugate binding was saturated. This study shows that multiepitope targeting enhances HER2-targeted photoimmunotherapy and maintains a high degree of specificity. Consequently, it seems that multitargeted photoimmunotherapy should also be useful against cancers that overexpress other receptors.

Breast Neoplasms↗

Magnetic-resonance-imaging-coupled broadband near-infrared tomography system for small animal brain studies.

A novel magnetic-resonance-coupled broadband near-infrared (NIR) tomography system for small animal brain studies is described. Several features of the image formation approach are new in NIR tomography and represent major advances in the path to recovering high-resolution hemoglobin and oxygen saturation images of tissue. The NIR data were broadband and continuous wave and were used along with a second-derivative-based estimation of the path length from water absorption. The path length estimation from water was then used along with the attenuation spectrum to recover absorption and reduced scattering coefficient images at multiple wavelengths and then to recover images of total hemoglobin and oxygen saturation. Going beyond these basics of NIR tomography, software has been developed to allow inclusion of structures derived from MR imaging (MRI) for the external and internal tissue boundaries, thereby improving the accuracy and spatial resolution of the properties in each tissue type. The system has been validated in both tissue-simulating phantoms, with 10% accuracy observed, and in a rat cranium imaging experiment. The latter experiment used variation in inspired oxygen (FiO2) to vary the observed hemoglobin and oxygen saturation images. Quantitative agreement was observed between the changes in deoxyhemoglobin values derived from NIR and the changes predicted with blood-oxygen-level-dependent (BOLD) MRI. This system represents the initial stage in what will likely be a larger role for NIR tomography, coupled to MRI, and illustrates that the technological challenges of using continuous-wave broadband data and inclusion of a priori structural information can be met with careful phantom studies.

Algorithms↗

Spectrally constrained chromophore and scattering near-infrared tomography provides quantitative and robust reconstruction.

A multispectral direct chromophore and scattering reconstruction technique has been implemented for near-infrared frequency-domain tomography in recovering images of total hemoglobin, oxygen saturation, water, and scatter parameters. The method applies the spectral constraint of the chromophores and scattering spectra directly in the reconstruction algorithm, thereby reducing the parameter space of the inversion process. This new method was validated by use of simulated and experimental data, and results show better robustness and stability in the presence of higher levels of noise. The method suppresses artifacts, especially those significant in water and scatter power images, and reduces cross talk between chromophore and scatter parameters. Variation in scattering was followed by this spectral approach successfully in experimental data from 90-mm-diameter cylindrical phantoms, and results show linear variation in scatter amplitude and reduced scattering coefficient (micro(s)'), with total hemoglobin, oxygen saturation, and water remaining constant and quantitatively accurate. Similar experiments were carried out for varying oxygen saturation and total hemoglobin. Accurate quantification was obtained with a mean error of 7.7% for oxygen saturation and 6.2% for total hemoglobin, with minimal cross talk between different parameters.

Algorithms↗

Effects of refractive index on near-infrared tomography of the breast.

Near infrared (NIR) optical tomography is an imaging technique in which internal images of optical properties are reconstructed with the boundary measurements of light propagation through the medium. Recent advances in instrumentation and theory have led to the use of this method for the detection and characterization of tumors within the female breast tissue. Most image reconstruction approaches have used the diffusion approximation and have assumed that the refractive index of the breast is constant, with a bulk value of approximately 1.4. We have applied a previously reported modified diffusion approximation, in which the refractive index for different tissues can be modeled. The model was used to generate NIR data from a realistic breast geometry containing a localized anomaly. Using this simulated data, we have reconstructed optical images, both with and without correct knowledge of the refractive-index distribution to show that the modified diffusion approximation can accurately recover the anomaly given a priori knowledge of refractive index. But using a reconstruction algorithm without the use of correct a priori information regarding the refractive-index distribution is shown as recovering the anomaly but with a degraded quality, depending on the degree of refractive index mismatch. The results suggest that provided the refractive index of breast tissue is approximately 1.3-1.4, their exclusion will have minimal effect on the reconstructed images.

Algorithms↗

Excitation patterns in three-dimensional electrical impedance tomography.

Electrical impedance tomography (EIT) is a non-invasive technique that aims to reconstruct images of internal electrical properties of a domain, based on electrical measurements on the periphery. Improvements in instrumentation and numerical modeling have led to three-dimensional (3D) imaging. The availability of 3D modeling and imaging raises the question of identifying the best possible excitation patterns that will yield to data, which can be used to produce the best image reconstruction of internal properties. In this work, we describe our 3D finite element model of EIT. Through singular value decomposition as well as examples of reconstructed images, we show that for a homogenous female breast model with four layers of electrodes, a driving pattern where each excitation plane is a sinusoidal pattern out-of-phase with its neighboring plane produces better qualitative images. However, in terms of quantitative imaging an excitation pattern where all electrode layers are in phase produces better results.

Algorithms↗

Assimilating intraoperative data with brain shift modeling using the adjoint equations.

Biomechanical models of brain deformation are increasingly being used to nonrigidly register preoperative MR (pMR) images of the brain to the surgical scene. These model estimates can potentially be improved by incorporating sparse displacement data available in the operating room (OR), but integrating the intraoperative information with model calculations is a nontrivial problem. We present an inverse method to estimate the unknown boundary and volumetric forces necessary to achieve a least-squares fit between the model and the data that is formulated in terms of the adjoint equations, which are solved directly by the method of representers. The scheme is illustrated in a 2D simulation and in a 2D approximation based on a patient case using actual OR data.

Algorithms↗

On optimal current patterns for electrical impedance tomography.

We develop a statistical criterion for optimal patterns in planar circular electrical impedance tomography. These patterns minimize the total variance of the estimation for the resistance or conductance matrix. It is shown that trigonometric patterns (Isaacson, 1986), originally derived from the concept of distinguishability, are a special case of our optimal statistical patterns. New optimal random patterns are introduced. Recovering the electrical properties of the measured body is greatly simplified when optimal patterns are used. The Neumann-to-Dirichlet map and the optimal patterns are derived for a homogeneous medium with an arbitrary distribution of the electrodes on the periphery. As a special case, optimal patterns are developed for a practical EIT system with a finite number of electrodes. For a general nonhomogeneous medium, with no a priori restriction, the optimal patterns for the resistance and conductance matrix are the same. However, for a homogeneous medium, the best current pattern is the worst voltage pattern and vice versa. We study the effect of the number and the width of the electrodes on the estimate of resistivity and conductivity in a homogeneous medium. We confirm experimentally that the optimal patterns produce minimum conductivity variance in a homogeneous medium. Our statistical model is able to discriminate between a homogenous agar phantom and one with a 2 mm air hole with error probability (p-value) 1/1000.

Algorithms↗

Adaptive model initialization and deformation for automatic segmentation of T1-weighted brain MRI data.

A fully automatic, two-step, T1-weighted brain magnetic resonance imaging (MRI) segmentation method is presented. A preliminary mask of parenchyma is first estimated through adaptive image intensity analysis and mathematical morphological operations. It serves as the initial model and probability reference for a level-set algorithm in the second step, which finalizes the segmentation based on both image intensity and geometric information. The Dice coefficient and Euclidean distance between boundaries of automatic results and the corresponding references are reported for both phantom and clinical MR data. For the 28 patient scans acquired at our institution, the average Dice coefficient was 98.2% and the mean Euclidean surface distance measure was 0.074 mm. The entire segmentation for either a simulated or a clinical image volume finishes within 2 min on a modern PC system. The accuracy and speed of this technique allow us to automatically create patient-specific finite element models within the operating room on a timely basis for application in image-guided updating of preoperative scans.

Algorithms↗

A three-parameter mechanical property reconstruction method for MR-based elastic property imaging.

A reconstruction process featuring full parameterization of the three dimensional, time-harmonic equations of linear elasticity is developed and reconstructed property images are presented from simulation-based investigation. While interesting in its own right through the potential for increased adaptability of these reconstructive elastic imaging techniques, this study also presents a set of analysis tools used to study the poor convergence behavior found in the case of tissue like conditions (i.e. nearly incompressible materials). The choice of elastic properties for imaging in elastography research remains an open question at this point; the use of the stability and sensitivity-based analytical methods described here will help to predict and understand the value and reliability of different parameterizations of elasticity imaging. Additionally, though results indicate significant work needs to be done to achieve effective multiparameter reconstructive imaging, the methods detailed here offer the promise of increased flexibility and sophistication in elastographic imaging techniques.

Algorithms↗

Stereopsis-guided brain shift compensation.

Brain deformation models have proven to be a powerful tool in compensating for soft tissue deformation during image-guided neurosurgery. The accuracy of these models can be improved by incorporating intraoperative measurements of brain motion. We have designed and implemented a passive intraoperative stereo vision system capable of estimating the three-dimensional shape of the surgical scene in near real-time. This intraoperative shape is compared with the cortical surface in the co-registered preoperative magnetic resonance (MR) volume for the estimation of the cortical motion resulting from the open cranial surgery. The estimated cortical motion is then used to guide a full brain model, which updates a preoperative MR volume. We have found that the stereo vision system is accurate to within approximately 1 mm. Based on data from two representative clinical cases, we show that stereopsis guidance improves the accuracy of brain shift compensation both at and below the cortical surface.

Algorithms↗

Near-infrared characterization of breast tumors in vivo using spectrally-constrained reconstruction.

Multi-wavelength Near-Infrared (NIR) Tomography was utilized in this study to non-invasively quantify physiological parameters of breast tumors using direct spectral reconstruction. Frequency domain NIR measurements were incorporated with a new spectrally constrained direct chromophore and scattering image reconstruction algorithm, which was validated in simulations and experimental phantoms. Images of total hemoglobin, oxygen saturation, water, and scatter parameters were obtained with higher accuracy than previously reported. Using this spectral approach, in vivo NIR images are presented and interpreted through a series of case studies (n=6 subjects) having differing abnormalities. The corresponding mammograms and ultrasound images are also evaluated. Three of six cases were malignant (infiltrating ductal carcinomas) and showed higher hemoglobin (34-86% increase), a reduction in oxygen saturation, an increase in water content as well as scatter changes relative to surrounding normal tissue. Three of six cases were benign, two of which were diagnosed with fibrocystic disease and showed a dominant contrast in water, consistent with fluid filled cysts. Scatter amplitude was the main source of contrast in the volunteer with the benign condition fibrosis, which typically contains denser collagen tissue. The changes monitored correspond to physiological changes associated with angiogenesis, hypoxia and cell proliferation anticipated in cancers. These changes represent potential diagnostic indicators, which can be assessed to characterize breast tumors.

Adult↗

Cortical surface tracking using a stereoscopic operating microscope.

OBJECTIVE: To measure and compensate for soft tissue deformation during image-guided neurosurgery, we have developed a novel approach to estimate the three-dimensional (3-D) topology of the cortical surface and track its motion over time. METHODS: We use stereopsis to estimate the 3-D cortical topology during neurosurgical procedures. To facilitate this process, two charge-coupled device cameras have been attached to the binocular optics of a stereoscopic operating microscope. Before surgery, this stereo imaging system is calibrated to obtain the extrinsic and intrinsic camera parameters. During surgery, the 3-D shape of the cortical surface is automatically estimated from a stereo pair of images and registered to the preoperative image volume to provide navigational guidance. This estimation requires robust matching of features between the images, which, when combined with the camera calibration, yields the desired 3-D coordinates. After the 3-D cortical surface has been estimated from stereo pairs, its motion is tracked by comparing the current surface with its previous locations. RESULTS: We are able to estimate the 3-D topology of the cortical surface with an average error of less than 1.2 mm. Executing on a 1.1-GHz Pentium machine, the 3-D estimation from a stereo pair of 1024 x 768 resolution images requires approximately 60 seconds of computation. By applying stereopsis over time, we are able to track the motion of the cortical surface, including the pulsatile movement of the cortical surface, gravitational sag, tissue bulge as a result of increased intracranial pressure, and the parenchymal shape changes associated with tissue resection. The results from 10 surgical patients are reported. CONCLUSION: We have demonstrated that a stereo vision system coupled to the operating microscope can be used to efficiently estimate the dynamic topology of the cortical surface during surgery. The 3-D surface can be coregistered to the preoperative image volume. This unique intraoperative imaging technique expands the capability of the current navigational system in the operating room and increases the accuracy of anatomic correspondence with preoperative images through compensation for brain deformation.

Adult↗

Absorption and scattering imaging of tissue with steady-state second-differential spectral-analysis tomography.

A novel approach to reconstructing both the absorption and the scattering properties of a turbid medium simultaneously from steady-state broadband spectral measurements is presented that utilizes second-differential fitting to the water spectrum to estimate the optical path length in tissue. Theoretical and experimental evidence is provided to demonstrate the robust accuracy of the spectroscopy approach and reconstructed absorption images. The steady-state broadband CCD system has the potential to provide accurate chromophore imaging without the technological complexity of time- or frequency-domain systems.

Absorption↗

Breast deformation modelling for image reconstruction in near infrared optical tomography.

Near infrared tomography (NIR) is a novel imaging technique that can be used to reconstruct tissue optical properties from measurements of light propagation through tissue. More specifically NIR measurements over a range of wavelengths can be used to obtain internal images of physiologic parameters and these images can be used to detect and characterize breast tumour. To obtain good NIR measurements, it is essential to have good contact between the optical fibres and the breast which in-turn results in the deformation of the breast due to the soft plasticity of the tissue. In this work, a tissue deformation model of the female breast is presented that will account for the altered shape of the breast during clinical NIR measurements. Using a deformed model of a breast, simulated NIR data were generated and used to reconstruct images of tissue absorption and reduced scatter using several assumptions about the imaging domain. Using either a circular or irregular 2D geometry for image reconstruction produces good localization of the absorbing anomaly, but it leads to degradation of the image quality. By modifying the assumptions about the imaging domain to a 3D conical model, with the correct diameter at the plane of NIR measurement, significantly improves the quality of reconstructed images and helps reduce image artefacts. Finally, assuming a non-deformed breast shape for image reconstruction is shown to lead to poor quality images since the geometry of the breast is greatly altered, whereas using the correct deformed geometry produces the best images.

Algorithms↗