Rater-dependent accuracy in predicting the spatial location of functional centers on anatomical MR images.

OBJECTIVES: The determination of eloquent cortex is essential when planning neurosurgical approaches to brain lesions. This study examined the abilities of medical personnel of various backgrounds to predict the location of functional cortex using anatomical information provided by MR imaging. PATIENTS AND METHODS: Neurosurgeons, neuroscientists, neuroradiologists, medical students and MR technologists viewed anatomical MR images acquired from patients with brain tumors and healthy controls. These five groups of raters were then asked to locate the primary motor hand, supplementary motor and primary auditory areas and their predictions were compared to fMRI data acquired from the same subjects. RESULTS: The overall mean distance from the center of the fMRI activation was 2.38 cm. The neuroscientists performed the best and MR technologists performed the worst (mean distance from center of 1.83 and 3.04 cm, respectively, p<0.05). The difference between patients and controls was not significant. The mean distance by ROI was primary motor hand 2.03 cm, auditory area 2.06 cm and supplementary motor area 3.18 cm (p<0.05). Raters also performed best in the medial-lateral direction, compared to superior-inferior and anterior-posterior directions (mean distances from center 0.42, 1.04 and 1.81 cm, respectively). Finally, the approximate minimum fields of view necessary to capture the entire fMRI activations using the raters' predictions ranged from 5 to 15 cm, or 3 to 12 cm larger than the fMRI activations. CONCLUSION: Medical personnel of various training perform poorly when using only anatomical information to predict the location of functional areas of cortex.

Adult↗

Does hands-on obstetric US experience improve performance on the radiology oral board examination?

PURPOSE: To investigate whether the inclusion of hands-on obstetric ultrasonography (US) experience as a formal part of radiology residency affects performance on the US section of the oral board examination. MATERIALS AND METHODS: An electronic survey was sent to all radiology residency programs to assess (a) the time assigned to US rotation, (b) the inclusion of obstetrics in US rotation, and (c) the opportunity for hands-on scanning of obstetric patients. Blinded results from the 2002 Diagnostic Radiology Oral Board Examination were provided by the American Board of Radiology. We recorded the overall examination score, US section score, and individual score for all obstetric cases for each resident from programs that responded to the survey. A Student t test and stratified statistical analyses were performed. This study was determined to be exempt from institutional review board approval. Residency directors who consented to participate were informed of pertinent information. RESULTS: Of the 159 programs, 64 (40.3%) responded and 63 (98%) of these had scores available. US section scores were provided for 280 residents, with 869 obstetric case scores. Fifty (79%) of 63 programs provided the opportunity for hands-on obstetric scanning. After adjusting for covariates, there was no significant difference in individual resident performance between residents with hands-on scanning experience and those without hands-on scanning experience (P = .61). When evaluated according to program, there was no significant difference in performance between programs with and those without hands-on training (P = .39). CONCLUSION: Radiology resident performance in obstetric US on the American Board of Radiology Oral Board Examination is similar for programs that provide the opportunity for hands-on obstetric scanning compared with those that do not.

Data Collection↗

Bayesian multivariate hierarchical transformation models for ROC analysis.

A Bayesian multivariate hierarchical transformation model (BMHTM) is developed for receiver operating characteristic (ROC) curve analysis based on clustered continuous diagnostic outcome data with covariates. Two special features of this model are that it incorporates non-linear monotone transformations of the outcomes and that multiple correlated outcomes may be analysed. The mean, variance, and transformation components are all modelled parametrically, enabling a wide range of inferences. The general framework is illustrated by focusing on two problems: (1) analysis of the diagnostic accuracy of a covariate-dependent univariate test outcome requiring a Box-Cox transformation within each cluster to map the test outcomes to a common family of distributions; (2) development of an optimal composite diagnostic test using multivariate clustered outcome data. In the second problem, the composite test is estimated using discriminant function analysis and compared to the test derived from logistic regression analysis where the gold standard is a binary outcome. The proposed methodology is illustrated on prostate cancer biopsy data from a multi-centre clinical trial.

Bayes Theorem↗

Quantitative evaluation of automated skull-stripping methods applied to contemporary and legacy images: effects of diagnosis, bias correction, and slice location.

Performance of automated methods to isolate brain from nonbrain tissues in magnetic resonance (MR) structural images may be influenced by MR signal inhomogeneities, type of MR image set, regional anatomy, and age and diagnosis of subjects studied. The present study compared the performance of four methods: Brain Extraction Tool (BET; Smith [2002]: Hum Brain Mapp 17:143-155); 3dIntracranial (Ward [1999] Milwaukee: Biophysics Research Institute, Medical College of Wisconsin; in AFNI); a Hybrid Watershed algorithm (HWA, Segonne et al. [2004] Neuroimage 22:1060-1075; in FreeSurfer); and Brain Surface Extractor (BSE, Sandor and Leahy [1997] IEEE Trans Med Imag 16:41-54; Shattuck et al. [2001] Neuroimage 13:856-876) to manually stripped images. The methods were applied to uncorrected and bias-corrected datasets; Legacy and Contemporary T1-weighted image sets; and four diagnostic groups (depressed, Alzheimer's, young and elderly control). To provide a criterion for outcome assessment, two experts manually stripped six sagittal sections for each dataset in locations where brain and nonbrain tissue are difficult to distinguish. Methods were compared on Jaccard similarity coefficients, Hausdorff distances, and an Expectation-Maximization algorithm. Methods tended to perform better on contemporary datasets; bias correction did not significantly improve method performance. Mesial sections were most difficult for all methods. Although AD image sets were most difficult to strip, HWA and BSE were more robust across diagnostic groups compared with 3dIntracranial and BET. With respect to specificity, BSE tended to perform best across all groups, whereas HWA was more sensitive than other methods. The results of this study may direct users towards a method appropriate to their T1-weighted datasets and improve the efficiency of processing for large, multisite neuroimaging studies.

Adult↗

Statistical combination schemes of repeated diagnostic test data.

RATIONALE AND OBJECTIVES: When diagnostic tests are repeated and combined, a number of schemes may be adopted. Guidelines for their interpretations are required. MATERIALS AND METHODS: Three combination schemes, "and" (A), "or" (O), and "majority" (M), are considered. To evaluate these schemes, dependency by specifying kappa values quantifying repeated test agreement was structured. In a pilot study, the combined accuracies of magnetic resonance imaging using six different pulse sequences of medial collateral ligaments of the elbows of 28 cadavers, with eight having lesions artificially created surgically, were examined. Images were evaluated simultaneously by using a five-point ordinal scale. For each pulse sequence, individuals for whom the diagnosis varied from once to three repetitions were considered. RESULTS: Scheme M improves diagnostic accuracy when sensitivity and specificity of a single test exceed 0.5, with maximal improvement at 0.79. Under scheme A, sensitivity decreases to 0.38-0.59. Under scheme O, sensitivity increases to 0.53-0.79. Scheme M yields a small improvement, reaching 0.50-0.71. Under scheme A, specificity increases to 0.95-0.98. Under scheme O, specificity decreases to 0.91-0.98. Scheme M also yields a small improvement, reaching 0.94-0.98. CONCLUSION: Scheme A is recommended for ruling in diagnoses, scheme O is recommended for ruling out diagnoses, and scheme M is neutral. Consequently, different schemes may be used to optimize the target diagnostic accuracy.

Algorithms↗

Does the phase of menstrual cycle affect MR-guided focused ultrasound surgery of uterine leiomyomas?

PURPOSE: To determine whether the phase of menstrual cycle at the time of MR-guided focused ultrasound surgery (MRgFUS) treatment for uterine leiomyomas affects treatment outcome. METHODS: We enrolled all patients participating in a prospective phase III clinical trial from our center who completed 6 months of clinical and imaging follow-up. Patients with irregular cycles and those on oral contraceptives were excluded. Data prospectively documenting the date of the last menstrual period (LMP) at the time of treatment, length and duration of cycle, and raw symptom severity score (SSS) from the Uterine Fibroid Symptom and Quality of Life questionnaire, at baseline and 6 months were collected. Proliferative phase patients were determined retrospectively as those who were treated within less than 14 days from LMP; secretory phase patients were classified as those who were treated greater than 14 days from LMP. RESULTS: A total of 58 patients were enrolled. There was no significant difference in the mean SSS at baseline and mean SSS at 6 months between patients treated in the proliferative versus secretory phase of the cycle. No significant difference in the SSS change from baseline to 6 months was seen between the two groups. CONCLUSIONS: Menstrual cycle phase does not influence MRgFUS treatment outcome. Symptomatic improvement occurs with treatment during either phase of the menstrual cycle. Thus, the scheduling of MRgFUS treatment need not be based upon the phase of the menstrual cycle.

Female↗

Three-dimensional fast-recovery fast spin-echo MRCP: comparison with two-dimensional single-shot fast spin-echo techniques.

PURPOSE: To retrospectively evaluate the technical quality of and the visibility of the biliary tree and pancreatic duct on magnetic resonance (MR) cholangiopancreatographic (MRCP) images obtained with a single-breath-hold three-dimensional (3D) fast-recovery fast spin-echo (FRFSE) sequence in comparison with conventional two-dimensional (2D) single-shot fast spin-echo (SSFSE) thin-section and thick-slab sequences. MATERIALS AND METHODS: Institutional review board approval was obtained; informed consent was not required for this HIPAA-compliant study. MRCP was performed at 1.5 T in 53 consecutive patients (25 men and 28 women, aged 23-84 years). A single-breath-hold volume acquisition was performed by using the 3D FRFSE sequence and the conventional 2D SSFSE sequences. Two radiologists graded studies obtained with each sequence in a blinded fashion, and the paired Student t test was used to assess differences in technical quality, visibility of eight individual ductal segments of the biliary tree and pancreatic duct, and number of ductal segments visualized per patient. RESULTS: Studies obtained with 3D FRFSE were of significantly higher technical quality than those obtained with thin-section 2D SSFSE (P < .02 for both readers). The 3D FRFSE maximum intensity projection reconstruction and 2D SSFSE thick-slab sequence proved statistically equivalent with regard to the overall visibility of the biliary tree and pancreatic duct and the number of ductal segments visualized per patient. In comparison with 2D SSFSE thin-section imaging, however, 3D FRFSE imaging produced an improved overall duct segment visibility grade of 0.45 on a three-point visibility scale (P < .001), with a corresponding average per-patient improvement of 1.9 out of eight possible fully visualized duct segments (P < .001). CONCLUSION: The 3D FRFSE sequence shows promise for improved visibility of the pancreatic duct and biliary tree, compared with the conventional 2D SSFSE thin-section and thick-slab approach, while permitting the entire MRCP examination to be performed in a single breath hold.

Adult↗

Supratentorial low-grade glioma resectability: statistical predictive analysis based on anatomic MR features and tumor characteristics.

PURPOSE: To retrospectively assess the main variables that affect the complete magnetic resonance (MR) imaging-guided resection of supratentorial low-grade gliomas. MATERIALS AND METHODS: Institutional review board approval was obtained for this retrospective HIPAA-compliant study, with the requirement for informed consent waived. Data from 101 patients (61 men, 40 women; mean age, 39 years; age range, 18-72 years) who had nonenhancing supratentorial mass lesions that were histopathologically diagnosed as low-grade (World Health Organization grade II) gliomas and consecutively underwent surgery with intraoperative MR imaging guidance were analyzed. There were 21 low-grade astrocytomas, 64 oligodendrogliomas, and 16 mixed oligoastrocytomas. Initial and residual tumor volumes were measured on intraoperative T2-weighted MR images and three-dimensional spoiled gradient-echo MR images. The anatomic relationships between the tumor and eloquent cortical and/or subcortical regions and the influence of these relationships on the extent of resection were analyzed on the basis of preoperative MR imaging findings. Summary measures, univariate Fisher exact test and t test, and multivariate logistic regression analyses were performed. RESULTS: Tumor volume ranged from 2.7-231.0 mL. Univariate analyses revealed the following tumor characteristics to be significant predictive variables of incomplete tumor resection: diffuse tumor margin on T2-weighted MR images, oligodendroglioma or oligoastrocytoma histopathologic type, and large tumor volume (P < .05 for all). Tumor involvement of the following structures was associated with incomplete resection: corpus callosum, corticospinal tract, insular lobe, middle cerebral artery, motor cortex, optic radiation, visual cortex, and basal ganglia (P < .05 for all). Multivariate analyses revealed that incomplete tumor resection was due to tumor involvement of the corticospinal tract (P < .01), large tumor volume (P < .01), and oligodendroglioma histopathologic type (P = .02). CONCLUSION: The main variables associated with incomplete tumor resection in 101 patients were identified by using statistical predictive analyses.

Adolescent↗

Use of productivity and financial indicators for monitoring performance in academic radiology departments: U.S. nationwide survey.

PURPOSE: To determine how productivity- and finance-related indicators are used by radiology departments to evaluate departmental performance. MATERIALS AND METHODS: The study met the criteria to be exempt from institutional review board approval. All subjects were informed of the purpose of the study and that their questionnaire responses would be kept confidential. For the study, a survey was sent to 132 members of the Society of Chairmen of Academic Radiology Departments (SCARD) nationwide. The survey was designed to (a) assess organizational information about hospital and radiology departments, (b) determine the types and mean numbers of productivity and financial indicators used by radiology departments, (c) determine how these indicators are used to influence departmental productivity, and (d) assess the reference-standard goals with which each indicator value was compared. A total of 77 variables were studied. Summary statistics, Spearman rank correlation coefficient, and chi2 analyses were performed. RESULTS: The response rate was 42% (55 of 132 surveyed SCARD members). The mean number of productivity indicators used by radiology departments was 4.55 +/- 2.56 (standard deviation), while the mean number of financial indicators used was 2.89 +/- 1.99. Twenty-two (40%) of the 55 responding departments used productivity indicators to monitor and provide feedback to radiologists, hospital leaders, and technical staff members for improved productivity, but only 11 (20%) departments used these indicators to compare personnel performances against specific productivity standards. The most frequent goal (of seven [13%] responding departments) of using the indicators was to increase the examination volume from the previous year by 5%-10%. CONCLUSION: Academic radiology departments across the United States do not use a standardized set of productivity and financial indicators to measure departmental performance. Examination volume is the most frequently used productivity indicator, whereas general expenses are commonly used as indicators of financial status.

Chi-Square Distribution↗

Clinical validity of a negative computed tomography scan in patients with suspected pulmonary embolism: a systematic review.

CONTEXT: The clinical validity of using computed tomography (CT) to diagnose peripheral pulmonary embolism is uncertain. Insufficient sensitivity for peripheral pulmonary embolism is considered the principal limitation of CT. OBJECTIVE: To review studies that used a CT-based approach to rule out a diagnosis of pulmonary embolism. DATA SOURCES: The medical literature databases of PubMed, MEDLINE, EMBASE, CRISP, metaRegister of Controlled Trials, and Cochrane were searched for articles published in the English language from January 1990 to May 2004. STUDY SELECTION: We included studies that used contrast-enhanced chest CT to rule out the diagnosis of acute pulmonary embolism, had a minimum follow-up of 3 months, and had study populations of more than 30 patients. DATA EXTRACTION: Two reviewers independently abstracted patient demographics, frequency of venous thromboembolic events (VTEs), CT modality (single-slice CT, multidetector-row CT, or electron-beam CT), false-negative results, and deaths attributable to pulmonary embolism. To calculate the overall negative likelihood ratio (NLR) of a VTE after a negative or inconclusive chest CT scan for pulmonary embolism, we included VTEs that were objectively confirmed by an additional imaging test despite a negative or inconclusive CT scan and objectively confirmed VTEs that occurred during clinical follow-up of at least 3 months. DATA SYNTHESIS: Fifteen studies met the inclusion criteria and contained a total of 3500 patients who were evaluated from October 1994 through April 2002. The overall NLR of a VTE after a negative chest CT scan for pulmonary embolism was 0.07 (95% confidence interval [CI], 0.05-0.11); and the negative predictive value (NPV) was 99.1% (95% CI, 98.7%-99.5%). The NLR of a VTE after a negative single-slice spiral CT scan for pulmonary embolism was 0.08 (95% CI, 0.05-0.13); and after a negative multidetector-row CT scan, 0.15 (95% CI, 0.05-0.43). There was no difference in risk of VTEs based on CT modality used (relative risk, 1.66; 95% CI, 0.47-5.94; P = .50). The overall NLR of mortality attributable to pulmonary embolism was 0.01 (95% CI, 0.01-0.02) and the overall NPV was 99.4% (95% CI, 98.7%-99.9%). CONCLUSION: The clinical validity of using a CT scan to rule out pulmonary embolism is similar to that reported for conventional pulmonary angiography.

Humans↗

Assessment of multiple sclerosis lesions with spherical harmonics: comparison of MR imaging and pathologic findings.

Spherical harmonics (SH) were used to approximate the volume and three-dimensional geometry of multiple sclerosis (MS) lesions in deceased patients. The institutional ethical committee does not require its approval for studies involving pathologic specimens. Pathologic findings were used as the reference standard. In addition, lesion volume was measured with cylindrical approximation (CA). Volumetric comparisons of biases were based on summary statistics, Spearman correlation, Wilcoxon test, and two-way analysis of variance. Shape comparison metrics included mean distance and Dice similarity coefficient (DSC). Eight of 11 lesions had smaller biases with SH method (P < .001). Median biases with SH and CA did not differ significantly, as compared with pathologic findings (r = 1.00 vs 0.99, respectively). Variances of the biases were significantly smaller for SH (P = .04). Ranges of normalized distance and DSC were 0.1%-2.5% and 75%-96%, respectively. Mean DSC was significantly higher than 70% (P < .001). SH method provided unbiased lesion volume and added geometric information that may enable a better understanding of the pathogenesis and lesion evolution over time.

Brain↗

The use of receiver operating characteristic curves in biomedical informatics.

Receiver operating characteristic (ROC) curves are frequently used in biomedical informatics research to evaluate classification and prediction models for decision support, diagnosis, and prognosis. ROC analysis investigates the accuracy of a model's ability to separate positive from negative cases (such as predicting the presence or absence of disease), and the results are independent of the prevalence of positive cases in the study population. It is especially useful in evaluating predictive models or other tests that produce output values over a continuous range, since it captures the trade-off between sensitivity and specificity over that range. There are many ways to conduct an ROC analysis. The best approach depends on the experiment; an inappropriate approach can easily lead to incorrect conclusions. In this article, we review the basic concepts of ROC analysis, illustrate their use with sample calculations, make recommendations drawn from the literature, and list readily available software.

Biomedical Engineering↗

A global goodness-of-fit test for receiver operating characteristic curve analysis via the bootstrap method.

OBJECTIVE: Medical classification accuracy studies often yield continuous data based on predictive models for treatment outcomes. A popular method for evaluating the performance of diagnostic tests is the receiver operating characteristic (ROC) curve analysis. The main objective was to develop a global statistical hypothesis test for assessing the goodness-of-fit (GOF) for parametric ROC curves via the bootstrap. DESIGN: A simple log (or logit) and a more flexible Box-Cox normality transformations were applied to untransformed or transformed data from two clinical studies to predict complications following percutaneous coronary interventions (PCIs) and for image-guided neurosurgical resection results predicted by tumor volume, respectively. We compared a non-parametric with a parametric binormal estimate of the underlying ROC curve. To construct such a GOF test, we used the non-parametric and parametric areas under the curve (AUCs) as the metrics, with a resulting p value reported. RESULTS: In the interventional cardiology example, logit and Box-Cox transformations of the predictive probabilities led to satisfactory AUCs (AUC=0.888; p=0.78, and AUC=0.888; p=0.73, respectively), while in the brain tumor resection example, log and Box-Cox transformations of the tumor size also led to satisfactory AUCs (AUC=0.898; p=0.61, and AUC=0.899; p=0.42, respectively). In contrast, significant departures from GOF were observed without applying any transformation prior to assuming a binormal model (AUC=0.766; p=0.004, and AUC=0.831; p=0.03), respectively. CONCLUSIONS: In both studies the p values suggested that transformations were important to consider before applying any binormal model to estimate the AUC. Our analyses also demonstrated and confirmed the predictive values of different classifiers for determining the interventional complications following PCIs and resection outcomes in image-guided neurosurgery.

Adolescent↗

A Bayesian hierarchical non-linear regression model in receiver operating characteristic analysis of clustered continuous diagnostic data.

Receiver operating characteristic (ROC) analysis is a useful evaluative method of diagnostic accuracy. A Bayesian hierarchical nonlinear regression model for ROC analysis was developed. A validation analysis of diagnostic accuracy was conducted using prospective multi-center clinical trial prostate cancer biopsy data collected from three participating centers. The gold standard was based on radical prostatectomy to determine local and advanced disease. To evaluate the diagnostic performance of PSA level at fixed levels of Gleason score, a normality transformation was applied to the outcome data. A hierarchical regression analysis incorporating the effects of cluster (clinical center) and cancer risk (low, intermediate, and high) was performed, and the area under the ROC curve (AUC) was estimated.

Bayes Theorem↗

Combining classifiers using their receiver operating characteristics and maximum likelihood estimation.

In any medical domain, it is common to have more than one test (classifier) to diagnose a disease. In image analysis, for example, there is often more than one reader or more than one algorithm applied to a certain data set. Combining of classifiers is often helpful, but determining the way in which classifiers should be combined is not trivial. Standard strategies are based on learning classifier combination functions from data. We describe a simple strategy to combine results from classifiers that have not been applied to a common data set, and therefore can not undergo this type of joint training. The strategy, which assumes conditional independence of classifiers, is based on the calculation of a combined Receiver Operating Characteristic (ROC) curve, using maximum likelihood analysis to determine a combination rule for each ROC operating point. We offer some insights into the use of ROC analysis in the field of medical imaging.

Artificial Intelligence↗

Three-dimensional assessment of MR imaging-guided percutaneous cryotherapy using multi-performer repeated segmentations: the value of supervised learning.

RATIONALE AND OBJECTIVES: Accurate and reproducible segmentations of two-dimensional images are an important prerequisite for assessing tumor ablations three dimensionally (3D). We evaluated whether supervised learning methods would improve multiperformer repeated segmentations of magnetic resonance images (MRI) obtained before and after MRI-guided cryotherapy of renal cell carcinoma. MATERIALS AND METHODS: Three medical students independently performed five manual segmentations of a biopsy-proven renal cell carcinoma that was treated with percutaneous MRI-guided cryotherapy. Using pretreatment (T2-weighted fast recovery fast spin echo [FRFSE]) and posttreatment (T1-weighted, fat-suppressed, dynamically enhanced) MRIs, regions of tumor cryonecrosis were segmented. The same tasks were repeated after an experienced abdominal radiologist provided supervised learning. Segmentation sensitivity was compared with an estimated 3D-ground truth via voxel counts for regions of tumor, both before and after treatment, and for the regions of cryonecrosis. The sensitivity of each repeated segmentation was compared against the estimated ground truth using sensitivity, overlap index, and volume (mL). RESULTS: Supervised learning significantly improved posttreatment segmentation sensitivity (P = .03). With supervised learning, the ranges of the performance metrics over the segmentation performers were: pretreated tumor, sensitivity 0.902-0.999, overlap index 0.935-0.961, and volume 19.15-23.71 mL; posttreated tumor, sensitivity 0.923-0.991, overlap index 0.952-0.981, and volume 20.67-22.70 mL; in the ablation zone, sensitivity 0.938-0.969, overlap index 0.940-0.962, and volume 31.79-32.36 mL. CONCLUSIONS: Supervised learning improved multiperformer repeated segmentations of MRIs obtained before and after MRI-guided percutaneous cryotherapy of renal cell carcinoma. These methods may prove useful in aiding the 3D assessment of percutaneous tumor ablations.

Aged↗

Statistical validation of brain tumor shape approximation via spherical harmonics for image-guided neurosurgery.

RATIONALE AND OBJECTIVES: Surgical planning now routinely uses both two-dimensional (2D) and three-dimensional (3D) models that integrate data from multiple imaging modalities, each highlighting one or more aspects of morphology or function. We performed a preliminary evaluation of the use of spherical harmonics (SH) in approximating the 3D shape and estimating the volume of brain tumors of varying characteristics. MATERIALS AND METHODS: Magnetic resonance (MR) images from five patients with brain tumors were selected randomly from our MR-guided neurosurgical practice. Standardized mean square reconstruction errors (SMSRE) by tumor volume were measured. Validation metrics for comparing performances of the SH method against segmented contours (SC) were the dice similarity coefficient (DSC) and standardized Euclidean distance (SED) measure. RESULTS: Tumor volume range was 22,413-85,189 mm3, and range of number of vertices in triangulated models was 3674-6544. At SH approximations with degree of at least 30, SMSRE were within 1.66 x 10(-5) mm(-1). Summary measures yielded a DSC range of 0.89-0.99 (pooled median, 0.97 and significantly >0.7; P < .001) and an SED range of 0.0002-0.0028 (pooled median, 0.0005). CONCLUSION: 3D shapes of tumors may be approximated by using SH for neurosurgical applications.

Adult↗

Practice patterns of nonvascular interventional radiology procedures at academic centers in the United States?

RATIONALE AND OBJECTIVES: To determine and analyze the patterns of practice of nonvascular interventional procedures in academic centers in the United States. MATERIALS AND METHODS: A survey was administered via e-mail to the chief residents of 112 academic radiology departments in the United States. Recipients of the survey were asked to identify which sections within their respective radiology departments performed each of 43 types of nonvascular interventional procedures. An additional entry for performance of procedures by non-radiologists was provided. A total of 66 (59%) recipients responded. The statistical method used was the analysis of contingency tables. RESULTS: Percutaneous abdominal biopsies are performed mainly by abdominal and body imaging sections (43/66, 65%), followed by vascular/interventional sections (21/66, 32%). Percutaneous abdominal drainages are performed mostly by abdominal, body imaging, and computed tomography sections (40/66, 61%), followed by vascular/interventional sections. Fluoroscopically guided procedures were performed most commonly by vascular/interventional sections, including percutaneous gastrostomy (40/66, 61%), percutaneous nephrostomy (42/66, 64%), and biliary interventions such as percutaneous transhepatic cholangiography (47/66, 71%). Breast and musculoskeletal procedures are performed by their respective sections most frequently. Non-radiologists perform a significant portion of certain types of procedures: paracenteses, thoracenteses, biliary interventions (particularly stone extractions), enterostomies (particularly percutaneous jejunostomies and cecostomies), and certain biopsies (kidney and prostate). CONCLUSIONS: Academic US radiology sections perform nonvascular interventional radiology procedures in a complex and nonuniform manner. The vascular/interventional sections and organ system and modality (especially CT) sections perform the bulk of the procedures included in the survey. Breast imaging sections predominate in procedures in their disciplines. A substantial number and amount of interventional radiology procedures are performed by non-radiologists.

Academic Medical Centers↗