PubMed Health⌕ Search

Biomedical subjects

Kengo Tanabe

Publications and source records attributed to Kengo Tanabe.

45 records · Page 3Linked to original sources

Evaluation of coronary remodeling after sirolimus-eluting stent implantation by serial three-dimensional intravascular ultrasound.

This study evaluates the response of the coronary vessel wall to implantation of the sirolimus-eluting stent (SES), Bx-VELOCITY, by using serial intravascular ultrasound. SESs have a major impact on the inhibition of in-stent neointimal hyperplasia. However, changes in the vessel wall and behind stent struts in animal models and humans have not been evaluated after SES implantation. Thirty-four patients who received a SES (n = 24) or a Bx-VELOCITY bare stent (BS) (n = 10) for single de novo coronary lesions and had serial motorized pullback 3-dimensional intravascular ultrasound were included. Stent, lumen, and vessel volumes were similar in the 2 groups at baseline. At follow-up, significantly larger lumen and lower neointimal hyperplasia volumes (0.7 vs 33 mm(3), p = 0.001) were seen in the SES group compared with the BS group. There was no significant difference between SES and BS in either the vessel volume (+2.4% vs +0.7%, p = NS) or the plaque behind stent volume change (+3.4% vs +2.5%, p = NS) from after the procedure to late follow-up. The stent edges also showed no significant difference between postprocedural and follow-up measurements, either in patients receiving SESs or BSs. No stented or edge segment required redilatation in the SES group, whereas 2 patients underwent repeat percutaneous coronary angioplasty in the BS group. In the SES group, 1 patient (4%) showed late acquired incomplete stent apposition. Thus, the SES is effective in inhibiting neointimal hyperplasia without affecting vessel volume and plaque behind the stent.

Angioplasty, Balloon, Coronary↗

TAXUS III Trial: in-stent restenosis treated with stent-based delivery of paclitaxel incorporated in a slow-release polymer formulation.

BACKGROUND: The first clinical study of paclitaxel-eluting stent for de novo lesions showed promising results. We performed the TAXUS III trial to evaluate the feasibility and safety of paclitaxel-eluting stent for the treatment of in-stent restenosis (ISR). METHODS AND RESULTS: The TAXUS III trial was a single-arm, 2-center study that enrolled 28 patients with ISR meeting the criteria of lesion length < or =30 mm, 50% to 99% diameter stenosis, and vessel diameter 3.0 to 3.5 mm. They were treated with one or more TAXUS NIRx paclitaxel-eluting stents. Twenty-five patients completed the angiographic follow-up at 6 months, and 17 of these underwent intravascular ultrasound (IVUS) examination. No subacute stent thrombosis occurred up to 12 months, but there was one late chronic total occlusion, and additional 3 patients showed angiographic restenosis. The mean late loss was 0.54 mm, with neointimal hyperplasia volume of 20.3 mm3. The major adverse cardiac event rate was 29% (8 patients; 1 non-Q-wave myocardial infarction, 1 coronary artery bypass grafting, and 6 target lesion revascularization [TLR]). Of the patients with TLR, 1 had restenosis in a bare stent implanted for edge dissection and 2 had restenosis in a gap between 2 paclitaxel-eluting stents. Two patients without angiographic restenosis underwent TLR as a result of the IVUS assessment at follow-up (1 incomplete apposition and 1 insufficient expansion of the stent). CONCLUSIONS: Paclitaxel-eluting stent implantation is considered safe and potentially efficacious in the treatment of ISR. IVUS guidance to ensure good stent deployment with complete coverage of target lesion may reduce reintervention.

Antineoplastic Agents, Phytogenic↗

Sirolimus-eluting stent for treatment of complex in-stent restenosis: the first clinical experience.

OBJECTIVES: In this study, we assess the value of sirolimus eluting stent (SES) implantation in patients with complex in-stent restenosis (ISR). BACKGROUND: The treatment of ISR remains a therapeutic challenge, since many pharmacological and mechanical approaches have shown disappointing results. The SESs have been reported to be effective in de-novo coronary lesions. METHODS: Sixteen patients with severe, recurrent ISR in a native coronary artery (average lesion length 18.4 mm) and objective evidence of ischemia were included. They received one or more 18 mm Bx VELOCITY SESs (Cordis Waterloo, Belgium). Quantitative angiographic and three-dimensional intravascular ultrasound (IVUS) follow-up was performed at four months, and clinical follow-up at nine months. RESULTS: The SES implantation (n = 26) was successful in all 16 patients. Four patients had recurrent restenosis following brachytherapy, and three patients had totally occluded vessels preprocedure. At four months follow-up, one patient had died and three patients had angiographic evidence of restenosis (one in-stent and two in-lesion). In-stent late lumen loss averaged 0.21 mm and the volume obstruction of the stent by IVUS was 1.1%. At nine months clinical follow-up, three patients had experienced four major adverse cardiac events (two deaths and one acute myocardial infarction necessitating repeat target vessel angioplasty). CONCLUSIONS: The SES implantation in patients with severe ISR lesions effectively prevents neointima formation and recurrent restenosis at four months angiographic follow-up.

Adult↗

Collateral formation in patients after percutaneous myocardial revascularization: a mechanism for improvement?

BACKGROUND: Percutaneous myocardial revascularization (PMR) has emerged as a novel therapeutic strategy for patients with ischemic heart disease not amendable to traditional revascularization approaches. Despite the symptomatic improvement documented in clinical trials, underlying mechanism remains unknown. METHODS: We assessed the coronary angiograms of 25 patients before and 6 months after the PMR procedures for collateral vessel formation. The Rentrop scoring system was used to score the extent of collateral vessel formation. The angiograms were analyzed by 2 independent reviewers. The change in Rentrop score and improvement in angina status was correlated. RESULTS: During follow-up period of 6 months, no patient died or suffered from myocardial infarction. Overall the mean Canadian Classification Society (CCS) class among the study patients was significantly improved from 3.5 to 2.4; mean difference = 1.08 (p < 0.0001). Among these, 8 (32%) had improvement of > 2 CCS classes (p = 0.003) (improvement group). The rest of the patients had either no change (n = 8; 32%) or improvement of 1 CCS class (n = 9; 36%) (no improvement group). The Rentrop score improved in 3 (12%), remained unchanged in 22 (88%) and deteriorated in 0 patient. Overall, there was no significant change in Rentrop score at 6-month follow-up; mean difference 0.13 (p = 0.08). There was also no correlation between the change in extent of collateral vessel formation and the improvement in angina status (correlation coefficient r = 0.09) at 6 months after PMR. CONCLUSION: Improvement in collateral vessel formation is unlikely to be a mechanism responsible for symptomatic improvement in patients after PMR.

Aged↗

Fate of side branches after coronary arterial sirolimus-eluting stent implantation.

The sirolimus-eluting stent (SES) is emerging as a potential solution for the prevention of restenosis. Although the outcome of side branches after stenting with an uncoated metal stent (UMS) has been reported, the fate of side branches after SES implantation is unknown. Furthermore, the absence of spontaneous recanalization of occluded side branches following intracoronary brachytherapy has been previously described and has been related to a delayed healing process. We assessed the procedural and 6-month follow-up angiograms of 238 patients enrolled in the RAVEL study, a double-blind controlled trial of the SES versus the UMS. Any side branch seen on the preprocedure angiogram and subsequently covered by the stent was evaluated. The side branch Thrombolysis In Myocardial Infarction (TIMI) flow grade was assessed at baseline and at follow-up by 2 observers. One hundred twenty-eight patients with > or =1 side branches were identified (63 patients in the SES group with 118 side branches, 65 patients in the UMS group with 124 side branches). Side branch occlusion occurred after stenting in 12 branches (10%) in the SES group and in 9 branches (7%) in the UMS group (p = NS). Of these occluded branches, spontaneous recanalization was observed in 11 branches (92%) in the SES group and in 6 branches (67%) in the UMS group at follow-up angiography (p = NS). Thus, the fate of side branches after SES implantation is favorable and at least as good as after UMS implantation.

Blood Vessel Prosthesis Implantation↗

Persistent inhibition of neointimal hyperplasia after sirolimus-eluting stent implantation: long-term (up to 2 years) clinical, angiographic, and intravascular ultrasound follow-up.

BACKGROUND: Early results of sirolimus-eluting stent implantation showed a nearly complete abolition of neointimal hyperplasia. The question remains, however, whether the early promising results will still be evident at long-term follow-up. The objective of our study was to evaluate the efficiency of sirolimus-eluting stent implantation for up to 2 years of follow-up. METHODS AND RESULTS: Fifteen patients with de novo coronary artery disease were treated with 18-mm sirolimus-eluting Bx-Velocity stents (Cordis) loaded with 140 microg sirolimus/cm2 metal surface area in a slow release formulation. Quantitative angiography (QCA) and intravascular ultrasound (IVUS) were performed according to standard protocol. Sirolimus-eluting stent implantation was successful in all 15 patients. During the in-hospital course, 1 patient died of cerebral hemorrhage after periprocedural administration of abciximab, and 1 patient underwent repeat stenting after 2 hours because of edge dissection that led to acute occlusion. Through 6 months and up to 2 years of follow-up, no additional events occurred. QCA analysis revealed no significant change in stent minimal lumen diameter or percent diameter stenosis, and 3-dimensional IVUS showed no significant deterioration in lumen volume. In 2 patients, additional stenting was performed because of significant lesion progression remote from the sirolimus-eluting stent. CONCLUSION: Sirolimus-eluting stents showed persistent inhibition of neointimal hyperplasia for up to 2 years of follow-up.

Abciximab↗

Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial.

BACKGROUND: The goal of this intravascular ultrasound investigation was to provide a more detailed morphological analysis of the local biological effects of the implantation of a sirolimus-eluting stent compared with an uncoated stent. METHODS AND RESULTS: In the RAVEL trial, 238 patients with single de novo lesions were randomized to receive either an 18-mm sirolimus-eluting stent (Bx VELOCITY stent, Cordis) or an uncoated stent (Bx VELOCITY stent). In a subset of 95 patients (sirolimus-eluting stent=48, uncoated stent=47), motorized intravascular ultrasound pullback (0.5 mm/s) was performed at a 6-month follow-up. Stent volumes, total vessel volumes, and plaque-behind-stent volumes were comparable. However, the difference in neointimal hyperplasia (2+/-5 versus 37+/-28 mm3) and percent of volume obstruction (1+/-3% versus 29+/-20%) at 6 months between the 2 groups was highly significant (P<0.001), emphasizing the nearly complete abolition of the proliferative process inside the drug-eluting stent. Analysis of the proximal and distal edge volumes showed no significant difference between the 2 groups in external elastic membrane or lumen and plaque volume at the proximal and distal edges. There was also no evidence of intrastent thrombosis or persisting dissection at the stent edges. Although there was a higher incidence of incomplete stent apposition in the sirolimus group compared with the uncoated stent group (P<0.05), it was not associated with any adverse clinical events at 1 year. CONCLUSIONS: Sirolimus-eluting stents are effective in preventing neointimal hyperplasia without creating edge effect and without affecting the plaque burden behind the struts.

Blood Vessel Prosthesis Implantation↗

No delayed restenosis at 18 months after implantation of sirolimus-eluting stent.

Sirolimus-eluting stent is emerging as a potential solution for the prevention of restenosis. Recently, a sustained suppression of neointimal proliferation 12 months after implantation of this stent was reported. This is the first report of angiographic and IVUS images 18 months after the implantation of a sirolimus-eluting stent.

Adult↗