PubMed Health⌕ Search

Biomedical subjects

Kenichiro Nakashima

Publications and source records attributed to Kenichiro Nakashima.

At least 19 recordsLinked to original sources

Semi-micro column high-performance liquid chromatography with UV detection for quantification of aspirin and salicylic acid and its application to patients' sera administered with low-dose enteric-coated aspirin.

A simultaneous determination of aspirin (ASA) and its metabolite, salicylic acid (SA), in human serum by a semi-micro column HPLC-UV was developed. A relatively small size of serum sample (100 microL) containing ASA and SA was cleaned up by a simple solid phase extraction. A good separation of ASA and SA could be achieved within 25 min using a semi-micro ODS column with an eluent of MeOH/0.7 mm phosphoric acid solution (pH 2.5) = 50:50 (v/v). The calibration curves for ASA and SA showed good linearity (r = 0.999) with the detection limits 114 and 38 ng/mL at a signal-to-noise ratio of 3, respectively. ASA and SA in patients' sera administered with low-dose enteric-coated aspirin were determined, and the concentration ranges obtained for ASA and SA were 1.2-2.2 and 0.5-57.3 microg/mL, respectively.

Aged↗

Determination of paclitaxel in human and rat blood samples after administration of low dose paclitaxel by HPLC-UV detection.

A simple and sensitive HPLC-UV method was developed for the determination of paclitaxel (TXL) in human and rat blood samples. 4-Hydroxybenzoic acid n-hexyl ester was used as an internal standard. TXL was extracted by a liquid-liquid extraction with tert-butylmethyl ether. The disturbing peaks in the case of serum sample were removed by pre-extraction with hexane. The separation of TXL was achieved within 25 min using an ODS column with 50% acetonitrile aqueous solution as a mobile phase at a flow rate of 1.0 mL/min. The eluent was monitored at 230 nm, and the resulted retention times of TXL and IS were 11.2 and 20.4 min. The detection limits of TXL for human plasma, serum and rat plasma samples at a signal-to-noise ratio of 3 were 10, 9.5 and 7.5 ng/mL, respectively. The proposed methods were applicable to the determination of TXL in human patients' plasma ranging from 15 to 27 ng/mL. Furthermore, monitoring of the time course of TXL after its single administration to rat could be demonstrated.

Aged↗

A sensitive semi-micro column HPLC method with peroxyoxalate chemiluminescence detection and column switching for determination of MDMA-related compounds in hair.

A sensitive semi-micro column HPLC method with peroxyoxalate chemiluminescence (POCL) detection and column switching has been developed for simultaneous determination of 3,4-methylenedioxymethamphetamine (MDMA) and related compounds, for example 3,4-methylenedioxyamphetamine, methamphetamine, and amphetamine, in hair. After digestion of the hair with 1 mol L-1 sodium hydroxide the compounds were extracted with n-heptane and derivatized with 4-(N,N-dimethylaminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole. A mixture of hydrogen peroxide and bis(2,4,5-trichloro-6-carbopentoxyphenyl)oxalate in acetonitrile was used as post-column CL reagent. Calibration plots showed linearity was good (r=0.999); detection limits were 0.02-0.16 ng mg-1 hair at a signal-to-noise ratio of 3. The precision of the method, as RSD (n=5), in intra-day and inter-day assays was better than 5.0 and 6.9%, respectively. The proposed method was sufficiently sensitive to detect low ng mg-1 levels of MDMA and related compounds in hair, and could be used for quantification of the compounds in hair samples from patients treated in a chemical dependency unit.

Calibration↗

Determination of haloperidol and reduced haloperidol in human serum by liquid chromatography after fluorescence labeling based on the Suzuki coupling reaction.

A simultaneous method for the determination of haloperidol (HP) and its metabolite, reduced haloperidol (RHP), in human serum was developed by means of high-performance liquid chromatography (HPLC) with fluorescence detection. Suzuki coupling reaction with a fluorescent arylboronic acid, 4-(4,5-diphenyl-1H-imidazol-2-yl)phenylboronic acid (DPA), was employed to convert HP and RHP into highly fluorescent compounds. HP and RHP were extracted from human serum by liquid-liquid extraction with a mixture of n-hexane and isoamyl alcohol (99:1, v/v) and subsequently labeled by reaction with DPA. Separation of DPA derivatives of HP and RHP was performed on a silica column with a mixture of acetonitrile and H(2)O (90:10, v/v) containing triethylamine and acetic acid as a mobile phase. The proposed method allowed sensitive detection of HP and RHP in human serum with a detection limit (at a signal to noise ratio of 3) of 0.22 and 0.20 ng/mL, respectively. The applicability of the method for therapeutic drug monitoring (TDM) was demonstrated by analyzing human serum samples from schizophrenic patients receiving HP.

Boron Compounds↗

Selective determination of quinones by high-performance liquid chromatography with on-line post column ultraviolet irradiation and peroxyoxalate chemiluminescence detection.

A new HPLC method was developed for the simultaneous determination of quinones with peroxyoxalate chemiluminescence (PO-CL) detection following on-line UV irradiation. Quinones [i.e., 1,2-naphthoquinone, 1,4-naphthoquinone, 9,10-anthraquinone, 9,10-phenanthrenequinone] were UV irradiated (254 nm, 15 W) to generate hydrogen peroxide and a fluorescent product that were determined via PO-CL detection. Generation of hydrogen peroxide from quinones with on-line UV irradiation was confirmed using flow injection analysis (FIA) system whereby incorporating an enzyme column reactor immobilized with catalase. Moreover, the structure of the produced fluorophore was confirmed using LC-MS, IR, and (1)H NMR. Afterwards, the conditions for UV irradiation and PO-CL detection were optimized. The separation of four quinones by HPLC was accomplished isocratically on an ODS column within 25 min. The detection limits (signal-to-noise ratio=3) were 6.0 pmol/injection for 1,2-naphthoquinone, 4.4 pmol/injection for 1,4-naphthoquinone, 0.2 pmol/injection for 9,10-anthraquinone, and 0.45 pmol/injection for 9,10-phenanthrenequinone.

Chromatography, High Pressure Liquid↗

Determination of donepezil hydrochloride in human and rat plasma, blood and brain microdialysates by HPLC with a short C30 column.

A simple and sensitive HPLC method with fluorescence (FL) detection for determination of donepezil (DP) in plasma and microdialysate samples was developed. A rapid isocratic separation of DP could be achieved by a short C30 column using mobile phases of 25 mM citric acid/50 mM Na2HPO4 (pH 6.0)-CH3CN (73:27%, v/v) containing 3.5 mM sodium 1-octanesulfonate for plasma and H2O-CH3CN-CH3OH (80:17:3%, v/v/v) containing 0.01% acetic acid for microdialysate. The eluate was monitored at 390 nm with an excitation at 325 nm. The detection limits (S/N = 3) of DP for human plasma, rat plasma and rat brain or blood microdialysates were 0.2, 1.0 and 2.1 ng/ml, respectively. Reproducible results could be obtained by using (+/-)-2-[(1-benzyl-piperidine-4-yl)ethyl]-5,6-dimethoxyindan-1-one hydrochloride as an internal standard (IS). The method was successfully applied for monitoring of DP levels in rat plasma, blood and brain microdialysates and patient plasma.

Animals↗

Determination of artemisinin in human serum by high-performance liquid chromatography with on-line UV irradiation and peroxyoxalate chemiluminescence detection.

Artemisinin is an antimalarial drug containing an internal endoperoxide linkage in its structure. A simple, selective and sensitive high-performance liquid chromatography (HPLC)-peroxyoxalate chemiluminescence (PO-CL) method for the determination of artemisinin was developed. This method is based on the fact that endoperoxide in artemisinin structure can be converted to hydrogen peroxide (H(2)O(2)) under ultraviolet (UV) irradiation and the generated hydrogen peroxide can be measured using PO-CL detection. The HPLC-PO-CL system was optimized on a mobile phase, post column chemiluminescence reagent, UV source and irradiation time. In addition, the system was combined with simple liquid-liquid extraction using n-hexane that allowed selective and sensitive determination of artemisinin in serum. The limit of detection using 0.5 mL of blood was 0.062 micromol/L (17.5 ng/mL) at a signal-to-noise ratio of 3. Calibration curve obtained for artemisinin in human serum 4-80 micromol/L (1.1-22.6 microg/mL) showed a good linearity (r = 0.999).

Artemisinins↗

A simple and sensitive HPLC-fluorescence method for quantification of MDMA and MDA in blood with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl) as a label.

A sensitive high-performance liquid chromatographic method with fluorescence detection to determine 3,4-methylenedioxymethamphethamine (MDMA) and 3,4-methylenedioxyamphethamine (MDA) in human and rat whole blood or plasma samples was developed by using 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl) as a label. MDMA and MDA in a small amount of blood sample (ca 100 microL) were extracted by liquid-liquid extraction with ethyl acetate, and were derivatized with DIB-Cl under mild conditions (10 min at room temperature). A good separation of DIB-derivatives could be achieved within 45 min using a commercially available ODS column with an isocratic eluent of 10 mM citric acid-20 mM Na(2)HPO(4) aqueous buffer (pH 4.0)-CH(3)CN-CH(3)OH (50:45:5, v/v/v %). The calibration curves prepared with 1-methyl-3-phenylpropylamine (MPPA) as an internal standard showed good linearity (r = 0.999) with 0.36-0.83 ng/mL detection limit at a signal-to-noise ratio of 3. MDMA and MDA in rat whole blood could be monitored for 6 h after a single administration of MDMA (2.2 mg/kg, i.p.). The pharmacokinetic parameters for MDMA and MDA obtained by triplicate measurements were 426 +/- 23 and 39 +/- 6 ng/mL (C(max)), 20 +/- 5 and 100 +/- 10 min (T(max)), respectively.

3,4-Methylenedioxyamphetamine↗

Evaluation of clinical markers of atherosclerosis in young and elderly Japanese adults.

BACKGROUND: In order to be able to take preventative measures early in life against the development of atherosclerosis, it is important to evaluate profiles of subclinical atherosclerosis, especially among young adults. METHODS: We screened plasma homocysteine levels, highly sensitive C-reactive protein levels and carotid intima-media thickness in young and elderly adults. RESULTS: Among both young and elderly adults, plasma homocysteine and highly sensitive C-reactive protein were significantly lower in females than in males. Highly sensitive C-reactive protein was significantly lower in young adults than in elderly adults, and homocysteine was lower (but not significantly) in young adults than in elderly adults. Among young adults, mean carotid intima-media thickness was lower (but not significantly) in females than in males. Among elderly adults, mean carotid intima-media thickness was significantly lower in females than in males. Among both males and females, mean carotid intima-media thickness was significantly higher in elderly adults than in young adults. CONCLUSIONS: These results demonstrate basic profiles of atherosclerosis markers in young and elderly Japanese adults. Further study is needed to evaluate measures developed for application in early adulthood to prevent atherosclerosis.

Adult↗

Sequential injection analysis with chemiluminescence detection for the antioxidative activity against singlet oxygen.

A sequential injection analysis (SIA) with chemiluminescence (CL) detection was developed for the measurement of antioxidative activity against singlet oxygen ((1)O2). Lactoperoxidase-hydrogen peroxide-bromide ion system was used for the generation of (1)O2. When a 100 mM sodium acetate buffer (pH 4.5) was used as a carrier solution, the SIA-CL system could be optimized with respect to the flow-rate of the carrier, concentration of reagents and their aspiration order. The antioxidative activity was expressed as an attenuation of luminol CL due to the quenching of (1)O2 by an antioxidant. The relative standard deviations of antioxidative activity (n=3) against (1)O2 for within- and between-day analyses were < or = 1.6% (20 microM Trolox). The system was successfully applied to the assay of antioxidative activities of various antioxidants including vitamin supplements at a rate of 10 samples within 15 min. The proposed SIA-CL system was rapid and reproducible with minimum consumption of the sample and of reagents, and thus was useful for the screening of compounds possessing antioxidative activity against (1)O2.

Antioxidants↗

Concentration and trend of 9,10-phenanthrenequinone in airborne particulates collected in Nagasaki city, Japan.

9,10-Phenanthrenequinone (PQ), one of the components of atmospheric pollutants, has potent harmful effects on human health. PQ in airborne particulates collected in Nagasaki city was determined by HPLC with fluorescence derivatization. PQ extracted from airborne particulates using methanol was derivatized with benzaldehyde in the presence of ammonium acetate to give a fluorescent compound. The average concentration (mean+/-SD, n=52) of PQ found in airborne particulates collected from July 1997 to June 1998 was 0.287+/-0.128 ng m-3. Concentrations of PQ in winter were higher than those in summer. In a weekly variation study, PQ concentrations were higher during weekdays and lower at weekend. The levels of PQ were obviously correlated with those of phenanthrene (PH) that is considered as a parent compound of PQ. This observation suggested that PQ was emitted into the atmosphere from the same source as PH, or PQ was converted from PH in the atmosphere.

Air Pollutants↗

Stereoselective HPLC assay of donepezil enantiomers with UV detection and its application to pharmacokinetics in rats.

This investigation describes a new precise, sensitive and accurate stereoselective HPLC method for the simultaneous determination of donepezil enantiomers in tablets and plasma with enough sensitivity to follow its pharmacokinetics in rats up to 12h after single oral dosing. Enantiomeric resolution was achieved on a cellulose tris (3,5-dimethylphenyl carbamate) column known as Chiralcel OD, with UV detection at 268 nm, and the mobile phase consisted of n-hexane, isopropanol and triethylamine (87:12.9:0.1). Using the chromatographic conditions described, donepezil enantiomers were well resolved with mean retention times of 12.8 and 16.3 min, respectively. Linear response (r > 0.994) was observed over the range of 0.05-2 microg/ml of donepezil enantiomers, with detection limit of 20 ng/ml. The mean relative standard deviation (R.S.D.%) of the results of within-day precision and accuracy of the drug were < or =10%. There was no significant difference (p > 0.05) between inter- and intra-day studies for each enantiomers which confirmed the reproducibility of the assay method. The mean extraction efficiency was 92.6-93.2% of the enantiomers. The proposed method was found to be suitable and accurate for the quantitative determination of donepezil enantiomers in tablets. The assay method also shows good specificity to donepezil enantiomers, and it could be successfully applied to its pharmacokinetic studies and to therapeutic drug monitoring.

Animals↗

Mechanism of permeability-enhancing effect of EDTA and boric acid on the corneal penetration of 4-[1-hydroxy-1-methylethyl]-2-propyl-1-[4-[2-[tetrazole-5-yl]phenyl]phenyl] methylimidazole-5-carboxylic acid monohydrate (CS-088).

This study was conducted to clarify the penetration properties of 4-[1-hydroxy-1-methylethyl]-2-propyl-1-[4-[2-[tetrazole-5-yl]phenyl]phenyl]methylimidazole-5-carboxylic acid monohydrate (CS-088), an ophthalmic agent, and the mechanism of the permeability-enhancing effect of EDTA and boric acid (EDTA/boric acid) on the corneal penetration of CS-088. In the absence of additives, corneal permeability decreased with increasing concentration of CS-088 as CS-088 monomers self-associate to form dimers. Presence of EDTA/boric acid caused no significant changes in the physicochemical properties of CS-088, the apparent partition coefficient or the mean particle size of CS-088. EDTA/boric acid induced only a slight change in the zeta potential of liposomes used as a model of the biological membrane. On the other hand, EDTA/boric acid significantly increased membrane fluidity of liposomes, whereas other buffering agents tested did not. This effect was synergistic and concentration-dependent for both EDTA and boric acid as was observed in in vitro corneal penetration of CS-088. In accordance with the result, the rate of CS-088 permeation into the liposomes significantly increased by the addition of EDTA/boric acid. Therefore, it was demonstrated that EDTA/boric acid promotes corneal penetration of CS-088 through the transcellular pathway by increasing membrane fluidity. Conversely, other buffering agents decreased corneal permeability of CS-088 by inducing further self-association of CS-088 aggregates.

1-Octanol↗

Fluorescence labeling method for aryl halides with 4-(4,5-diphenyl-1H-imidazol-2-yl)phenylboronic acid based on Suzuki coupling reaction.

For the first time, fluorescence labeling methods for aryl halides with a fluorescent arylboronic acid was developed on the basis of a Suzuki coupling reaction. 4-(4,5-diphenyl-lH-imidazol-2-yl)phenylboronic acid (DPA) was used as a fluorescence labeling reagent. In order to explore its analytical performance, the reaction conditions were optimized using simple bromobenzene derivatives. The reactivity was then investigated with chloro- and iodobenzene derivatives, and also bromobenzene derivatives with different position of substituents. The order of reactivity with DPA: iodobenzene > bromobenzene more more than chlorobenzene derivatives, and p- > m- > o-substituted bromobenzenes. The detection limits of bromobenzene, 4-bromotoluene, and 4-bromoanisole ranged from 0.2 to 1.4 pmol/injection at a signal-to-noise ratio, (S/N) of 3. The applicability of the method to biological samples was also evaluated using clofibrate as the analyte. The reaction was found not only to proceed well but also to be selective for clofibrate even in the presence of plasma components. The method allowed the sensitive detection of clofibrate in human plasma with the detection limit of 170 pmol/mL (260 fmol/injection) at a S/N = 3. The proposed method is highly selective and sensitive and thus would be useful for labeling of aryl halides that do not have other functional groups that could be labeled by currently available fluorescent labeling reagents.

Benzene↗

Stepwise gradient of buffer concentration for capillary electrochromatography of peptides on sulfonated naphthalimido-modified silyl silica gel.

The advantage of using a stepwise gradient of buffer concentration in CEC was demonstrated with the mixed-mode stationary phase, 3-(4-sulfo-1,8-naphthalimido)propyl-modified silyl silica gel (SNAIP). Before the application of a stepwise gradient, the effect of buffer concentration on the separations of six peptides and tryptic digests was investigated. Bubble formation caused by Joule heating at currents up to 95 microA was successfully suppressed by using SNAIP column even without pressurization, which contributed to a stepwise gradient of buffer concentration. Utilizing the stepwise gradient improved and shortened the separation of six peptides as compared to the separation under an isocratic elution.

Buffers↗

Capillary electrochromatography of caffeine and its metabolites in rat brain microdialysate.

A capillary electrochromatography (CEC) method has been developed for the separation of caffeine and its two metabolites 1-methylxanthine (1-MX) and 1,7-dimethylxanthine (1,7-DX). The stationary phase was 3-(1,8-naphthalimido) propyl-modified silyl silica gel (NAIP) and the best separations were achieved with 4.0 mM citrate buffer (pH 5.0) containing 80% methanol at an applied voltage of 25 kV. The compounds were completely separated in less than 3.5 min with good repeatability, which was approximately 3-times less than that in high-performance liquid chromatography (HPLC) with NAIP. The proposed method coupled with microdialysis was successfully applied to the monitoring of caffeine concentration in rat brain with detection limits of 1.11 microg/mL.

Animals↗

Investigation of a novel mixed-mode stationary phase for capillary electrochromatography. Part III: Separation of nucleosides and nucleic acid bases on sulfonated naphthalimido-modified silyl silica gel.

Capillary electrochromatography (CEC) with a novel stationary phase, 3-(4-sulfo-1,8-naphthalimido)propyl-modified silyl silica gel (SNAIP), proved useful for the separation of nucleosides and nucleic acid bases. The application scope of SNAIP, which is a relatively polar reversed-phase (RP)-type stationary phase, was successfully expanded to include the CEC separation of polar compounds although the combination of non-polar RP phase with highly aqueous mobile phase is often inadequate. Due to the permanently charged sulfonic acid groups and the naphthalimidopropyl moiety, the retention of charged and relatively polar nucleosides as well as bases on the SNAIP stationary phase was effected by electrostatic and hydrophobic interactions. This yielded a unique selectivity on SNAIP toward nucleosides and bases. The characteristic EOF on SNAIP, which was stronger at higher aqueous content in the mobile phase, proved suitable for the separation of polar compounds in reversed-phase mode with highly aqueous mobile phase. In addition, when a double stepwise gradient was employed to accelerate the latest peak (adenine), the elution time was shortened to less than half its original duration.

Buffers↗