PubMed Health⌕ Search

Biomedical subjects

Kenji Itani

Publications and source records attributed to Kenji Itani.

3 recordsLinked to original sources

Evaluation of the hemodynamics of the femoral head compared with the ilium, femoral neck and femoral intertrochanteric region in healthy adults: measurement with positron emission tomography (PET).

OBJECTIVE: Non-traumatic osteonecrosis of the femoral head (ONF) is considered to be a disease that occurs primarily due to ischemia of the femoral head, while its etiology and pathology are not fully understood. It is therefore necessary to identify the characteristics of the hemodynamics of the femoral head. In this study, the hemodynamics in the ilium and proximal regions of the femur, including the femoral head, was investigated using positron emission tomography (PET). METHODS: The subjects of this study consisted of 8 hip joints of four healthy male adults and 3 hip joints on the contralateral side of a femoral neck fracture, avulsion fracture of the greater trochanter and coxarthrosis (1 case each, all females) for a total of 11 hip joints of 7 subjects. The ages of the subjects ranged from 25 to 87 years (average age: 54 years). Blood flow was measured by means of the H215O dynamic study method and blood volume was measured by means of the 15O-labeled carbon monoxide bolus inhalation method. RESULTS: Blood flow was determined to be 9.1 +/- 4.8 ml/min/100 g in the ilium and among proximal regions of the femur (femoral head, neck and intertrochanteric region), 1.8 +/- 0.7 ml/min/100 g in the femoral head, 2.1 +/- 0.6 ml/min/100 g in the femoral neck, and 2.6 +/- 0.7 ml/min/100 g in the intertrochanteric region. In addition, blood volume was 4.7 +/- 1.3 ml/100 g in the ilium, and among proximal regions of the femur, 1.1 +/- 0.5 ml/100 g in the femoral head, 2.1 +/- 0.7 ml/100 g in the femoral neck, and 2.6 +/- 0.9 ml/100 g in the intertrochanteric region. The results showed that both blood flow and volume were lowest in the femoral head. Blood flow and volume were significantly lower in the proximal regions of the femur (femoral head, neck and intertrochanteric region) than in the ilium (p < 0.01). CONCLUSION: The present study demonstrated that the femoral head is in a hypoemic state as compared with other osseous tissue, indicating that even the slightest exacerbation of hemodynamics in the femoral head can trigger an ischemic condition culminating in ONF.

Adult↗

Reliability of one-point blood sampling method for calculating input function in Na18F PET.

OBJECTIVE: Conventional methods of quantitative Na18F positron emission tomography require multiple arterial blood sampling in order to obtain the input function, and the procedures are invasive and complicated. This study aims to establish a simplified and reliable technique for obtaining the input function. METHODS: Multiple arterial blood sampling was performed on 12 persons. The time point for one-point sampling was determined as the time when (1) the plasma radioactivity obtained showed the highest correlation to the real integrated value, which was calculated from the input function, and (2) the coefficient of variation of the real integrated value divided by plasma radioactivity obtained at each time point became the minimum. Scaling factors were obtained in order to estimate the plasma radioactivity at each time point, and a reference table was produced in order to estimate the input function. RESULTS: The optimal timing for one-point sampling was 12 min after intravenous injection of Na18F. The estimated integrated value obtained from arterial blood sampling at 12 min and the reference table was highly correlated with the real integrated value (P<0.001). Levels of plasma radioactivity of arterial blood and venous blood were almost the same at 12 and 40 min after Na18F injection. Percentage errors in the estimation of the integrated value were 2.63% (n=12) for the arterial blood collected at 12 min and 4.14% (n=12) for the venous blood collected at 30 min. CONCLUSIONS: This simplified method is clinically applicable and would replace traditional methods that require multiple blood sampling.

Adult↗

[Short time bacterial endotoxins test for positron emission tomography by means of positively charged filters].

Positron emission tomography (PET) radiotracers have very short physical half-lives. It is hard to complete a bacterial endotoxins test prior to release from medical institutes. For endotoxin quantitative determination, limulus amebocyte lysate (LAL) reagent and kinetic-turbidimetry system were previously developed. We investigated the possibility of a short time test by means of positively charged filters. As a result of this study, the effects of positively charged filters on endotoin removal were over 99.5% for [18F]FDG and [18F]NaF, which were contaminated with the indicated concentration of endotoxin. Combining this filter and the kinetic-turbidimetric method, it was possible to complete a bacterial endotoxins test in 5 min prior to the patient's administration. This test should be required prior to release for PET radiopharmaceutical quality control. It has been suggested that this combination is a good method for this purpose.

Drug Contamination↗