PubMed Health⌕ Search

Biomedical subjects

Kenjirou Ohashi

Publications and source records attributed to Kenjirou Ohashi.

7 recordsLinked to original sources

Peroneal tendon subluxation and dislocation: detection on volume-rendered images--initial experience.

Institutional review board approval was received and informed consent was not required for this Health Insurance Portability and Accountability Act-compliant study. The purpose of this study was to retrospectively assess the time efficiency of three-dimensional volume-rendered images obtained from multi-detector row computed tomographic data for the diagnosis of peroneal tendon subluxation or dislocation by using the consensus interpretation of multiplanar reformatted (MPR) images as the reference standard. The reference standard was provided by two musculoskeletal radiologists, and two less experienced readers evaluated 37 images in 32 patients (24 men, eight women; mean age, 41 years; age range, 18-75 years) with acute calcaneal fractures. An analysis of variance was used to compare interpretation time, and the Wilcoxon signed rank test was used to analyze diagnostic difficulty. The average time required for diagnosis was significantly shorter with volume-rendered images than with MPR images (reader 1: 42 vs 78 seconds, P<.001; reader 2: 50 vs 69 seconds, P<.01).

Adolescent↗

Interobserver agreement for Letournel acetabular fracture classification with multidetector CT: are standard Judet radiographs necessary?

PURPOSE: To retrospectively evaluate interobserver agreement for Letournel acetabular fracture classification with radiography alone and multidetector computed tomography (CT) alone and to retrospectively assess whether standard Judet views lead to a change in the classification. MATERIALS AND METHODS: Institutional review board approval was obtained; informed consent was not required for this HIPAA-compliant study, which included 101 imaging studies performed in 99 patients (78 male, 21 female; mean age, 43 years; age range, 15-86 years) with acetabular fractures. Two musculoskeletal radiologists independently classified the fractures with radiography alone and multidetector CT alone. Multiplanar reformatted and three-dimensional (3D) CT images were reviewed at a computer workstation. Readers were shown radiographs at the end of multidetector CT image reading to see if this would change the multidetector CT-based classification. kappa Values were calculated to assess interobserver agreement. For surgically treated patients, the McNemar test was used to compare the accuracy of readers' classifications. The reference standard was a combination of preoperative radiographic and multidetector CT image findings and intraoperative findings. RESULTS: Interobserver agreement was moderate (kappa = 0.42) with radiography and substantial (kappa = 0.70) with multidetector CT. Multidetector CT classification was changed in two cases (one case for each reader) after standard Judet views were added. In 73 surgically treated patients, agreement with the surgeons' classification was higher with multidetector CT than with radiography (P < .01 for one reader, P = .06 for the other reader). CONCLUSION: There is substantial interobserver agreement for Letournel acetabular fracture classification with multiplanar reformatted and 3D multidetector CT images. Standard Judet pelvic radiographs add little information for changing the multidetector CT classification.

Acetabulum↗

Acute traumatic spinal epidural hematoma: imaging and neurologic outcome.

The purpose of this study was to present MRI characteristics of traumatic spinal epidural hematomas (TSEHs) and to evaluate their effect on neurologic outcome. A retrospective analysis was performed of all 74 cases in which patients underwent emergent spinal MRI in the setting of acute trauma at our institution's Emergency Department between June 2002 and January 2003. MRI studies were evaluated for the presence of a TSEH. CT studies were evaluated for the presence of osseous trauma. Patient data were collected from medical records on the initial neurologic status at admission and at 6 months after injury. Twenty-seven of 74 patients had a spinal fracture and a TSEH. Twenty-five of 74 patients had a spinal fracture with no TSEH. Twenty-two of 74 patients had normal imaging studies. Six-month follow-up of neurologic status demonstrated no statistically significant difference in neurologic outcome between patients with spinal fractures and TSEH and those with spinal fractures but no TSEH. If a spinal fracture and abnormal neurologic exam are present, the neurologic outcome at 6 months is not worsened by the presence of a TSEH.

Adult↗

Orthopedic hardware complications diagnosed with multi-detector row CT.

PURPOSE: To retrospectively evaluate multi-detector row computed tomography (CT) for the depiction of orthopedic hardware complications in the spine and appendicular skeleton. MATERIALS AND METHODS: This HIPAA-compliant study had institutional review board approval; patient informed consent was not required. Results of 114 multi-detector row CT studies performed because of possible hardware complications in 109 patients (57 men, 52 women; mean age, 44 years; age range, 12-82 years) were available for analysis. The CT studies were retrospectively reviewed and compared with clinical or surgical outcomes, which were used as the reference standard. In another experiment, detection of hardware complications on radiographs and multi-detector row CT images was compared between two readers for selected cases (18 positive and 26 negative) by using receiver operating characteristic (ROC) methods. RESULTS: For 91 (80%) of 114 multi-detector row CT studies, the complication status could be determined on the basis of clinical or surgical outcomes. Twenty-three multi-detector row CT studies were confirmed to be positive (revealing 10 cases of nonunion, five cases of hardware malplacement, three cases of hardware loosening, three perihardware fractures, and two chronic infections), and 57 were confirmed to be negative. There were three false-positive and eight false-negative multi-detector row CT studies. With clinical or surgical outcomes as the reference standard, the sensitivity, specificity, and positive and negative predictive values of multi-detector row CT were 74% (23 of 31 studies), 95% (57 of 60 studies), 88% (23 of 26 studies), and 88% (57 of 65 studies), respectively. Results of ROC analysis indicated that detection of hardware complications was much lower with radiography than with multi-detector row CT (area under ROC curve, 0.84 vs 1.00; F = 4.69, df = 1, 43; P < .05). CONCLUSION: Multi-detector row CT is an effective tool for depicting orthopedic hardware complications.

Adolescent↗

Patellar fractures after total knee replacement.

OBJECTIVE: The objective of our study was to describe the patterns of patellar fracture after total knee replacement and assess their clinical significance. MATERIALS AND METHODS: A retrospective review of patellar fractures after total knee replacement was performed. Seventeen cases were identified over a 10-year period. Radiographs, radiology reports, medical records, and operative notes were reviewed and analyzed. The clinical analysis included the time to fracture, the patient's symptoms and signs, whether the extensor mechanism was disrupted, and the treatment administered for the fracture. The radiographic analysis included fracture pattern, displacement, patellar position, presence of patellar osteonecrosis, and presence of soft-tissue abnormality. RESULTS: The incidence of patellar fractures after total knee replacement was 1.14%. The mean time from total knee replacement to patellar fracture was 17.5 months. Nine fractures were asymptomatic and identified on routine follow-up radiographs. The patterns of fracture were diverse: Transverse (n = 6), comminuted (n = 2), vertical (n = 5), and avulsion (n =4) fractures were seen. Thirteen fractures were displaced. Patellar osteonecrosis was suspected in four fractures, and three fractures were associated with disruption of the quadriceps tendons. Thirteen fractures were treated nonoperatively, and four were treated surgically. CONCLUSION: Patellar fractures are an uncommon, but important, complication after total knee replacement. Radiologists should be familiar with the imaging features of these fractures and their clinical significance.

Aged↗

Ball-thrower's fracture of the humerus.

A relatively rare case of ball-thrower's fracture of the humerus is presented. Severe muscular action is an uncommon cause of humeral fractures but has been well documented in the orthopedic literature. To our knowledge, this fracture has not been described in the radiology literature, and awareness of this entity could preclude further unnecessary workup. The mechanism of injury and its typical radiographic appearance is described.

Adult↗

Spondyloarthropathies: ankylosing spondylitis and psoriatic arthritis.

As advances in the treatment of ankylosing spondylitis continue, TNF-alpha blocking agents may eventually be used as a first-line treatment. MR imaging could then be used to aid in the early diagnosis of ankylosing spondylitis by identifying early sacroiliitis, followed by immediate initiation of treatment to prevent the progression of the disease with its accompanying morbidities. Currently, radiographic identification of sacroiliitis remains the mainstay in diagnosing ankylosing spondylitis. In ankylosing spondylitis and psoriasis, MR imaging can demonstrate areas that are undergoing active inflammatory changes and enthesitis, aiding in the diagnosis of a spondyloarthropathy.

Adult↗