PubMed Health⌕ Search

Biomedical subjects

Kenneth C Parker

Publications and source records attributed to Kenneth C Parker.

5 recordsLinked to original sources

Methodology utilizing MS signal intensity and LC retention time for quantitative analysis and precursor ion selection in proteomic LC-MALDI analyses.

This study describes a methodology for performing relative quantitation in large-scale proteomic sample comparisons using an LC-MALDI mass spectrometry analytical platform without the use of isotope tagging reagents. The method utilizes replicate analyses of a sample to create a profile of constituent components that are aligned based on LC elution time and mass. Once components from individual runs have been grouped as common "features", the Student's t test is used to determine which components are systematically different between samples. In this study, five HPLC runs of human plasma were compared to five HPLC runs of human serum. About 3889 components were detected in all 10 runs. Of these, 1831 corresponded to approximately 100 known serum proteins, based on MS/MS analysis of one run each from serum and plasma. As expected, fibrinogen alpha, beta, and gamma chains accounted for many of the most significant differences. Therefore, using MALDI, samples containing thousands of peptides can be compared in a minimal amount of time. Moreover, the results of the comparison can be used to guide further MS/MS mode sample interrogation in a result dependent manner.

Animals↗

Electronic Western blot of matrix-assisted laser desorption/ionization mass spectrometric-identified polypeptides from parallel processed gel-separated proteins.

Identification of proteins previously separated by one-dimensional (1-D) or two-dimensional gel electrophoresis requires significant manipulations to digest the proteins into their respective peptides and to extract them from the gel prior to mass analysis. This article describes the simultaneous transfer and digestion of proteins directly from 1-D gels onto a membrane ready for matrix-assisted laser desorption/ionization (MALDI) mass spectrometric (MS) analysis. Protein transfer and digestion efficiencies are estimated to be more than 95%. The effectiveness of this procedure is demonstrated by identifying 110 unique proteins derived from a lysate of Escherichia coli and 149 proteins derived from a mouse liver homogenate separated by 1-D sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Using crude mouse liver homogenates, four distinct glutathione S-transferase classes, ranging from 23 to 27 kDa, are identified from a separating gel, indicating the discriminating potential for this method. A Visual Basic program allowed visualization of the identified proteins according to their respective positions on the 1-D gels. In many cases, two or more proteins could be identified within a single band of the SDS gel. The "digital" images generated resemble Western blots without the use of antibodies or signal amplification techniques.

Amino Acid Sequence↗

Depth of proteome issues: a yeast isotope-coded affinity tag reagent study.

As a test case for optimizing how to perform proteomics experiments, we chose a yeast model system in which the UPF1 gene, a protein involved in nonsense-mediated mRNA decay, was knocked out by homologous recombination. The results from five complete isotope-coded affinity tag (ICAT) experiments were combined, two using matrix-assisted laser desorption/ionization (MALDI) tandem mass spectrometry (MS/MS) and three using electrospray MS/MS. We sought to assess the reproducibility of peptide identification and to develop an informatics structure that characterizes the identification process as well as possible, especially with regard to tenuous identifications. The cleavable form of the ICAT reagent system was used for quantification. Most proteins did not change significantly in expression as a consequence of the upf1 knockout. As expected, the Upf1 protein itself was down-regulated, and there were reproducible increases in expression of proteins involved in arginine biosynthesis. Initially, it seemed that about 10% of the proteins had changed in expression level, but after more thorough examination of the data it turned out that most of these apparent changes could be explained by artifacts of quantification caused by overlapping heavy/light pairs. About 700 proteins altogether were identified with high confidence and quantified. Many peptides with chemical modifications were identified, as well as peptides with noncanonical tryptic termini. Nearly all of these modified peptides corresponded to the most abundant yeast proteins, and some would otherwise have been attributed to "single hit" proteins at low confidence. To improve our confidence in the identifications, in MALDI experiments, the parent masses for the peptides were calibrated against nearby components. In addition, five novel parameters reflecting different aspects of identification were collected for each spectrum in addition to the Mascot score that was originally used. The interrelationship between these scoring parameters and confidence in protein identification is discussed.

Amino Acid Sequence↗

Result-driven strategies for protein identification and quantitation--a way to optimize experimental design and derive reliable results.

Uni- or multidimensional microcapillary liquid chromatography (microLC) matrix-assisted laser desorption/ionization (MALDI) tandem mass spectrometry (MS/MS) approaches have gained significant attention for quantifying and identifying proteins in complex biological samples. The off-line coupling of microLC with MS quantitation and MS/MS identification methods makes new result-dependent workflows possible. A relational database is used to store the results from multiple high performance liquid chromatography runs, including information about MALDI plate positions, and both peptide and protein quantitations, and identifications. Unlike electrospray methodology, where all the decisions about which peptide to fragment, must be made during peptide fractionations, in the MALDI experiments the samples are effectively "frozen in time". Therefore, additional MS and MS/MS spectra can be acquired, to promote more accurate quantitation or additional identifications until reliable results are derived that meet experimental design criteria. In the case of what can be designated the expression-dependent workflow, quantitation can be detached from identification and only peak pairs with biological relevant expression changes can be selected for further MS/MS analyses. Alternatively, additional MS/MS data can be acquired to confirm tentative peptide mass fingerprint hits in what is designated a search result-dependent workflow. In the MS data-dependent workflow, the goal is to collect as many meaningful spectra as possible by judiciously adjusting the acquisition parameters based on characteristics of the parent masses. This level of sophistication requires the development of innovative algorithms for these three result-dependent workflows that make MS and MS/MS analysis more efficient and also add confidence to experimental results.

Chromatography, High Pressure Liquid↗

Scoring methods in MALDI peptide mass fingerprinting: ChemScore, and the ChemApplex program.

No universally accepted score is currently available to determine when a matrix-assisted laser desorption ionization (MALDI) peptide mass fingerprint (PMF) experiment has been successfully carried out. We describe a software program (ChemApplex) based on a calculated parameter (Combined Protein Score) that takes into account (1) peak intensity, (2) the mass accuracy of the match, and (3) ChemScore, a theoretical intensity factor that estimates the probability of observing a particular peptide based on a combination of chemical considerations, in particular the amino acid composition of the peptide and the amino acid sequence of the amino acids that span the cleavage site. When these three factors are taken into account both at the level of individual peptides and at the protein level, protein components in mixtures whose peptides contribute less than 1% of the total intensity can often be correctly identified, as is demonstrated for mixtures of standard proteins. Moreover, it is possible to make robust database identifications that are nearly independent of the number of masses submitted and the mass error threshold used for matching. Protein scoring based on Combined Protein Score is orthogonal to many of the commonly used probability-based scoring schemes, and makes it possible to archive a more complete set of parameters that more thoroughly characterize the validity of the database match, which increases the confidence in the identifications.

Amino Acid Sequence↗