An endothelial cell compatible biosensor fabricated using optically thin indium tin oxide silicon nitride electrodes.

This study describes the fabrication and performance of an endothelial cell compatible, optically thin, indium tin oxide (ITO) microimpedance biosensor. The biosensor was constructed by sputtering a thin insulating layer of silicon nitride (Si(3)N(4)) onto a 100 nm thick ITO layer. Indium tin oxide electrodes were formed by chemically etching 250 or 500 microm diameter holes through the Si(3)N(4) insulating layer. The exposed ITO electrode was electrically connected to an ITO counter electrode, approximately 2 cm(2) in area, via a 400 microL well containing cell culture media. A lock-in amplifier circuit monitored the impedance of porcine pulmonary artery endothelial cells (PPAECs) cultivated on the electrodes as a function of frequency, between 10 and 100 kHz, and as a function of time, at 5.62 kHz. The ITO-Si(3)N(4) microelectrodes provided consistent and repeatable impedance measurements to the attachment and spreading of PPAECs. In addition, the ITO-Si(3)N(4) electrodes were recyclable, robust, resistant to ethanol sterilization, and had a high optical transmittance. Most importantly, the ITO-Si(3)N(4) electrodes allowed optical access for dynamic cellular attachment imaging. The 5.62 kHz time dependent cellular impedance response to the drug Cytochalasin D further demonstrated the feasibility of using this electrode configuration for dynamic cellular impedance studies.

Animals↗

Experimental verification of near-wall hindered diffusion for the Brownian motion of nanoparticles using evanescent wave microscopy.

A total internal reflection fluorescence microscopy technique coupled with three-dimensional tracking of nanoparticles is used to experimentally verify the theory on near-wall hindered Brownian motion [Goldman et al., Chem. Eng. Sci. 22, 637 (1967); Brenner, Chem. Eng. Sci. 16, 242 (1967)] very close to the solid surface (within approximately 1 microm). The measured mean square displacements (MSDs) in the lateral x-y directions show good agreement with the theory for all tested nanoparticles of radii 50, 100, 250, and 500 nm. However, the measured MSDs in the z direction deviate substantially from the theory particularly for the case of smaller particles of 50 and 100 nm radius. Since the theory considers only the hydrodynamic interaction of moving particles with a stationary solid wall, additionally possible interaction forces like gravitational forces, van der Waals forces, and electro-osmotic forces have been examined to delineate the physical reasons for the discrepancy.

Journal Article↗