PubMed Health⌕ Search

Biomedical subjects

Kenneth Fan

Publications and source records attributed to Kenneth Fan.

3 recordsLinked to original sources

Dissolution studies of bovine dental enamel surfaces modified by high-speed scanning ablation with a lambda = 9.3-microm TEA CO(2) laser.

BACKGROUND AND OBJECTIVES: Previous studies have demonstrated that lasers can be used to modify the chemical composition of dental enamel to render the mineral phase more resistant to acid dissolution with minimal peripheral thermal damage. Transverse excited atmospheric (TEA) CO(2) lasers tuned to the strong mineral absorption of hydroxyapatite (HAP) near lambda = 9 microm are well-suited for the efficient ablation of dental hard tissues if the laser-pulse is stretched to greater than 5-10 microseconds to avoid plasma shielding phenomena. Moreover, TEA CO(2) lasers can be operated at very high repetition rates and are inherently less expensive and more versatile than Er:YAG and Er:YSGG solid-state lasers. In this study a lambda = 9.3-microm TEA CO(2) with a pulse duration of 8 microseconds and a repetition rate of 300 Hz was used to uniformly treat bovine enamel surfaces at ablative irradiation intensities. We hypothesized that a uniform surface layer of modified enamel of improved crystallinity and CaP phase composition would be formed with an enhanced resistance to acid-dissolution in the ablated areas at higher scanning rates used with the water spray. Such a modified layer of enamel formed at the base and walls of a cavity preparation under the irradiation conditions employed in this study have the potential to inhibit secondary caries under sealants and restorations. STUDY DESIGN/MATERIALS AND METHODS: The surfaces of bovine enamel blocks (3 x 3 mm(2)) were rapidly scanned across the laser beam at rates of 2, 3, and 6 mm/second with and without a water-spray at an incident fluence of 30 J/cm(2). The resistance to acid dissolution was evaluated using controlled surface dissolution experiments on laser-irradiated and control samples. RESULTS: The groups irradiated at a fluence of 30 J/cm(2) with a repetition rate of 300 Hz and a high scan rate of 6 mm/second with and without water-cooling significantly reduced the overall surface dissolution rates (P < 0.001). At low scan rates (2-3 mm/second) excessive heat deposition resulted in the formation of an outer layer of asperities containing non-apatitic CaP phases that were more susceptible to acid-dissolution. At a scanning rate of 6 mm/second even without the water spray a layer of purer phase HAP was formed without thermal damage, indicating that a high scanning rate can be used to avoid excessive thermal damage during ablation. The best results (80% inhibition) were attained for the higher scanning speed 6-mm/second combined with a water spray. CONCLUSION: This study demonstrates that an enamel surface with enhanced resistance to acid dissolution is produced after ablation with lambda = 9.3-microm TEA CO(2) laser pulses delivered at high-repetition rates if sufficiently high scanning rates are used with or without a water-spray.

Animals↗

Rapid and conservative ablation and modification of enamel, dentin, and alveolar bone using a high repetition rate transverse excited atmospheric pressure CO2 laser operating at lambda=9.3 micro.

Transverse excited atmospheric pressure (TEA) CO(2) lasers tuned to the strong mineral absorption of hydroxyapatite near lambda=9 microm are well suited for the efficient ablation of dental hard tissues if the laser pulse is stretched to greater than 5 to 10 micros to avoid plasma shielding phenomena. Such CO(2) lasers are capable of operating at high repetition rates for the rapid removal of dental hard tissues. The purpose of this study was to test the hypothesis that stretched lambda=9.3-microA CO(2) laser pulses can produce lateral incisions in enamel, dentin, and alveolar bone for dental restorations and implants at repetition rates as high as 400 Hz without peripheral thermal damage. The single pulse ablation rates through enamel, dentin, and bone were determined for incident fluence ranging from (1 to 160 J/m(2)) for laser pulses from 5 to 18 mus in duration. Lateral incisions were produced in hard tissue samples using a computer-controlled scanning stage and water spray, and the crater morphology and chemical composition were measured using optical microscopy and high-resolution synchrotron radiation infrared spectromicroscopy. The residual energy remaining in tooth samples was measured to be 30 to 40% for enamel and 20 to 30% for dentin without water cooling, under optimum irradiation intensities, significantly lower than for longer CO(2) laser pulses. The transmission through 2-m length 300-, 500-, 750-, and 1000-microm silica hollow waveguides was measured and 80% transmission was achieved with 40 mJ per pulse. These results suggest that high repetition rate TEA CO(2) laser systems operating at lambda=9.3 microm with pulse durations of 10 to 20 micros are well suited for dental applications.

Animals↗