The athletic hernia: a systematic review.

The athletic hernia is an obscure condition of uncertain etiology commonly seen in soccer and rugby players. The pain is often debilitating and may place an athletic career at risk. Treatment failures are frustrating to the athlete and the physician. The anatomy involved, diagnostic criteria, and treatment modalities are inconsistently described in the medical, surgical and orthopaedic literature. There is no evidence-based consensus available to guide decision-making. We performed an overview of the anatomy and pathoanatomy and a systematic review of the literature to gain insight into the disease and its treatment. Most studies are Level IV. The most common operative finding is a deficient posterior wall of the inguinal canal, although other abdominal wall abnormalities are frequently found. Open and laparoscopic repairs produce excellent results, but the latter allows earlier return to play. Magnetic resonance imaging appears to have excellent diagnostic potential for athletic hernia. A multidisciplinary approach to groin pain in the athlete is recommended.

Athletic Injuries↗

External fixation techniques for distal radius fractures.

UNLABELLED: Fractures of the distal radius are common injuries. Low-energy or high-energy mechanisms may be involved. Unstable distal radius fractures present a challenge to the treating orthopaedic surgeon. External fixation is a valuable instrument for fracture reduction and stabilization. Limited open incisions, early range of motion, and treatment of complex wounds are a few of the benefits of external fixation. Fixators may be spanning or nonbridging and may be used alone or in combination with other stabilization methods to obtain and maintain distal radius fracture reduction. Augmentation with percutaneous wires allows for optimal fracture stabilization with physiologic alignment of the wrist. Moderate distraction at the carpus does not induce postoperative stiffness. The distal radioulnar joint must be assessed and may need to be stabilized. Complications of external fixation are usually minor, but must be anticipated and treated early. LEVEL OF EVIDENCE: Level V (expert opinion).

Aftercare↗

Gunshot wounds: bullet caliber is increasing, 1998-2003.

In 1999, Caruso reported data from the level 1 trauma center in Newark, New Jersey, documenting "...an ominous trend toward the use of larger caliber firearms in accidents, homicides and suicides." Those data were derived from measurements of bullets removed from our trauma patients and submitted to the Surgical Pathology laboratory from 1981 through 1997. We further document this trend with measurements of similar source bullets from 1998 through 2002. During the same time, we recorded mortality among gunshot wound victims treated at our trauma center. Bullets submitted to surgical pathology during the years 1998 through 2002 were measured with a millimeter rule to determine caliber or transverse diameter. A total of 367 bullets were studied in this 5-year period. Bullets deformed beyond measurability (approximately 22%) and shotgun pellets (< 5%) were excluded from our study. Bullet calibers were expressed in terms of mean plus or minus standard error (x +/- SE). Mortality figures were derived from analysis of medical records concerning the outcomes all victims of gunshot wounds (E 922, E 965) treated at our hospital during the years studied and expressed as percentages. Linear regression of mean bullet caliber over time was performed, and analysis of variance was used to assess statistical significance of apparent differences in mortality. Bullet caliber continued to increase from 8.47 +/- 0.22 to 9.16 +/- 0.15 mm during the 5-year observation period. Linear regression reveals R = 0.9649, P < 0.01. Mortality ranged from 4.7 per cent to 10.7 per cent but the differences were not significant (P > 0.20). These data support a continued trend toward the use of larger caliber firearms in accidents, homicides, and suicides. Mortality does not change during this time and presumably because of improvements in treatment, from resuscitation to definitive surgery and its convalescence.

Cause of Death↗

Acute complications associated with greenfield filter insertion in high-risk trauma patients.

BACKGROUND: Use of Greenfield filters (GFs) to prevent fatal pulmonary embolism (PE) in trauma patients is generally well accepted. Nonetheless, a surprisingly small number of trauma surgeons insert filters in their patients. Among the reasons cited is fear of complications. METHODS: We observed three femoral arteriovenous fistulae (AVF) in trauma patients who had inferior vena caval placement of filters for PE prophylaxis in one 12-month period (academic year 1999). In an effort to document the magnitude of this problem, we evaluated trauma patients who had a GF inserted in academic year 2000. RESULTS: During that year, 133 consecutive patients (8.6% of trauma admissions) received 133 GFs through a percutaneous approach. The most common isolated indications for GF insertion included closed head injuries (n = 28), multiple long bone fractures (n = 27), pelvic and acetabular fractures (n = 6), spinal cord injuries (n = 16), and vertebral fractures (n = 3). Five patients had documented deep venous thrombosis (DVT) diagnosed by duplex ultrasonography before GF placement, and 11 patients had other indications requiring a filter. There were 37 patients with more than one indication requiring filter placement. Most patients (57%) underwent preinsertion duplex scanning of their lower extremity veins; 77% of patients underwent postinsertion scanning. Filters were inserted an average of 6.8 +/- 0.6 (SE) days after trauma. No AVF were suspected clinically or detected ultrasonographically. No operative or postoperative complications occurred. DVT was observed in 30% of patients despite 92% prophylaxis; there was a 26% incidence of de novo thrombi detected. None of the patients evidenced DVT clinically. CONCLUSION: Our data indicate that complications of GF insertion for prophylaxis against PE from DVT complicating trauma patients continue to be negligible. In addition, the incidence of insertion-site thrombosis may be lower than expected. Moreover, femoral AVF is a rare complication of this procedure.