PubMed Health⌕ Search

Biomedical subjects

Kevin A Snook

Publications and source records attributed to Kevin A Snook.

3 recordsLinked to original sources

High-frequency ultrasound annular-array imaging. Part I: array design and fabrication.

This is Part I of a series of two papers describing the development of a digital high-frequency, annular-array, ultrasonic imaging system. In this paper, the design and fabrication of a high-frequency annular array as well as its performance will be reported. A six-element, 50 MHz array, which incorporated an acoustic lens to provide an initial focal point, was designed and fabricated. A submicron size grain lead titanate piezoelectric ceramic was used to both reduce lateral coupling and keep the electrical impedance matched close to the 50 ohm receive electronics. The array elements were isolated using laser micromachining to fully separate the annuli, and electrical interconnection was achieved by directly soldering thin wires to the elements. The resulting array attained an average impulse response that exhibited a 43 MHz center frequency, 30% relative bandwidth, and an average insertion loss of 31 dB at 45 MHz. Maximum next-element crosstalk was -27 dB in water.

Computer-Aided Design↗

High-frequency ultrasound annular array imaging. Part II: digital beamformer design and imaging.

This is the second part of a two-paper series reporting a recent effort in the development of a high-frequency annular array ultrasound imaging system. In this paper an imaging system composed of a six-element, 43 MHz annular array transducer, a six-channel analog front-end, a field programmable gate array (FPGA)-based beamformer, and a digital signal processor (DSP) microprocessor-based scan converter will be described. A computer is used as the interface for image display. The beamformer that applies delays to the echoes for each channel is implemented with the strategy of combining the coarse and fine delays. The coarse delays that are integer multiples of the clock periods are achieved by using a first-in-first-out (FIFO) structure, and the fine delays are obtained with a fractional delay (FD) filter. Using this principle, dynamic receiving focusing is achieved. The image from a wire phantom obtained with the imaging system was compared to that from a prototype ultrasonic backscatter microscope with a 45 MHz single-element transducer. The improved lateral resolution and depth of field from the wire phantom image were observed. Images from an excised rabbit eye sample also were obtained, and fine anatomical structures were discerned.

Animals↗

Design, fabrication, and evaluation of high frequency, single-element transducers incorporating different materials.

The performance of high frequency, single-element transducers depends greatly on the mechanical and electrical properties of the piezoelectric materials used. This study compares the design and performance of transducers incorporating different materials. The materials investigated include 1-3 lead zirconate titanate (PZT) fiber composite, lead titanate (PbTiO3) ceramic, poly(vinylidene fluoride) (PVDF) film, and lithium niobate (LiNbO3) single crystal. All transducers were constructed with a 3-mm aperture size and an f-number between 2 and 3. Backing and matching materials were selected based on design goals and fabrication limitations. A simplified coaxial cable tuning method was employed to match the transducer impedance to 50 ohms for the PZT fiber composite and PbTiO3 ceramic transducers. Transducers were tested for two-way loss and -6 dB bandwidth using the pulse/echo response from a flat quartz target. Two-way loss varied from 21 to 46 dB, and bandwidths measured were in the range from 47 to 118%. In vitro ultrasonic backscatter microscope (UBM) images of an excised human eye were obtained for each device and used to compare imaging performance. Both press-focusing and application of a lens proved to be useful beam focusing methods for high frequency. Under equal gain schemes, the LiNbO3 and PbTiO3 transducers provided better image contrast than the other materials.

Equipment Design↗