Kevin Ashley

Publications and source records attributed to Kevin Ashley.

15 recordsLinked to original sources

Vacuum sampling techniques for industrial hygienists, with emphasis on beryllium dust sampling.

The U.S. Department of Energy (DOE) Chronic Beryllium Disease Prevention Program Rule, 10 CFR Part 850 became effective in 2000 in response to the prevalence of Chronic Beryllium Disease (CBD) in workers. The rule requires surface and air monitoring for beryllium to determine exposure levels and the evaluation of the effectiveness of controls used to minimize or eliminate that risk. The most common methods for surface sampling use wet or dry wipes. Wipe sampling techniques may be impractical for many surfaces common to most buildings such as cinder block, textured wall surfaces, fabric and carpet. Vacuum sampling methods have been developed for the evaluation of lead or pesticides on residential surfaces such as carpets, bare floors and window sills. However, the current vacuum methods may be impractical for many workplace situations such as sampling of protective clothing, complex facility structures, or equipment surfaces. Recent work using vacuum sampling for potential bio-terrorism agents such as anthrax spores may have significant application to industrial hygiene evaluations of the workplace and may be extendable for use in sampling of metals such as beryllium. Validated vacuum sampling methods that provide meaningful data would be of great value to industrial hygienists in identifying areas having surface contamination, evaluating existing controls and work practices and determining the potential of toxic material on surfaces to become airborne and present a potential risk to workers and the public. This article discusses various vacuum sampling methodologies and recommends harmonization of sampling methods.

Beryllium↗

Validation of a standardized portable fluorescence method for determining trace beryllium in workplace air and wipe samples.

Beryllium is widely used in industry for its unique properties; however, occupational exposure to beryllium particles can cause potentially fatal disease. Consequently, exposure limits for beryllium particles in air and action levels on surfaces have been established to reduce exposure risks for workers. Field-portable monitoring methods for beryllium are desired in order to facilitate on-site measurement of beryllium in the workplace, so that immediate action can be taken to protect human health. In this work, a standardized, portable fluorescence method for the determination of trace beryllium in workplace samples, i.e., air filters and dust wipes, was validated through intra- and inter-laboratory testing. The procedure entails extraction of beryllium in 1% ammonium bifluoride (NH(4)HF(2), aqueous), followed by fluorescence measurement of the complex formed between beryllium ion and hydroxybenzoquinoline sulfonate (HBQS). The method detection limit was estimated to be less than 0.02 microg Be per air filter or wipe sample, with a dynamic range up to greater than 10 microg. The overall method accuracy was shown to satisfy the accuracy criterion (A< or = +/-25%) for analytical methods promulgated by the US National Institute for Occupational Safety and Health (NIOSH). Interferences from numerous metals tested (in >400-fold excess concentration compared to that of beryllium) were negligible or minimal. The procedure was shown to be effective for the dissolution and quantitative detection of beryllium extracted from refractory beryllium oxide particles. An American Society for Testing and Materials (ASTM) International voluntary consensus standard based on the methodology has recently been published.

Air Pollutants↗

Trace-level beryllium analysis in the laboratory and in the field: state of the art, challenges and opportunities.

Control of workplace exposure to beryllium is a growing issue in the United States and other nations. As the health risks associated with low-level exposure to beryllium are better understood, the need increases for improved analytical techniques both in the laboratory and in the field. These techniques also require a greater degree of standardization to permit reliable comparison of data obtained from different locations and at different times. Analysis of low-level beryllium samples, in the form of air filters or surface wipes, is frequently required for workplace monitoring or to provide data to support decision-making on implementation of exposure controls. In the United States and the United Kingdom, the current permissible exposure level is 2 microg m(-3) (air) and the United States Department of Energy has implemented an action level of 0.2 microg m(-3) (air) and 0.2 microg/100 cm(2) (surface). These low-level samples present a number of analytical challenges, including (1) a lack of suitable standard reference materials, (2) unknown robustness of sample preparation techniques, (3) interferences during analysis, (4) sensitivity (sufficiently low detection limits), (5) specificity (beryllium speciation) and (6) data comparability among laboratories. Additionally, there is a need for portable, real-time (or near real-time) equipment for beryllium air monitoring and surface wipe analysis that is both laboratory-validated and field-validated in a manner that would be accepted by national and/or international standards organizations. This paper provides a review of the current analytical requirements for trace-level beryllium analysis for worker protection and also addresses issues that may change those requirements. The current analytical state of the art and relevant challenges facing the analytical community will be presented, followed by suggested criteria for real-time monitoring equipment. Recognizing and addressing these challenges will present opportunities for laboratories, research and development organizations, instrument manufacturers and others.

Accreditation↗

Evaluation of a standardized method for determining soluble silver in workplace air samples.

Several occupational exposure limits and guidelines exist for silver, but the values for each depend on the chemical form of the silver compound in question. In the past, it generally was not possible, without prior knowledge of the work process, to distinguish soluble silver from insoluble silver compounds collected in workplace air samples. Therefore, analytical results were historically reported as total silver. In this study, work was conducted to evaluate a method to differentiate between the quantities of water-soluble silver compounds and total silver collected on filters. The investigation entailed an evaluation of an International Organization for Standardization method to determine soluble silver in airborne particulate matter. The study design incorporated laboratory experiments to evaluate analytical figures of merit, such as selection of appropriate filter media and extraction solution, analytical recovery, and sample stability during storage. Polytetrafluoroethylene (PTFE) filters (2 microm, 37 mm) in opaque cassettes were either spiked with known amounts of silver nitrate or contained a known mass of solid silver nitrate. Results showed that over 90% of the silver was recovered from PTFE filters. Also, field studies were conducted in which workplace air samples were collected in two silver refineries. Some of these samples were analyzed only for soluble silver while others were sequentially extracted and analyzed, first, for soluble silver, then for total silver. The mass fractions of soluble silver, as compared to total silver, were approximately 2% or less. This investigation served to validate an international standard procedure for the determination of soluble silver in workplace air samples.

Air Pollutants, Occupational↗

Field evaluation of a portable blood lead analyzer in workers living at a high altitude: a follow-up investigation.

BACKGROUND: Field-portable instruments can offer expeditious analytical results to health professionals in field settings and in areas lacking laboratory infrastructure. This study further evaluated an electroanalytical field-portable instrument, which rapidly analyzes blood lead concentrations. METHODS: A portable anodic stripping voltammetry (ASV) instrument was evaluated utilizing paired samples from 243 employees working at an elevation of approximately 3,800 meters in Peru. Each worker donated two venous blood samples, one of which was analyzed by the ASV device and the other by a reference analytical method, graphite furnace atomic absorption spectrometry (GFAAS). RESULTS: According to the GFAAS results, the mean blood lead concentration measured was 46(+/-16) mug/dl; this was significantly greater than the mean ASV measurement of 32(+/-11) mug/dl (paired t-test; P < 0.0001). The accuracy of the ASV estimation decreased as the measured blood lead concentration increased. CONCLUSIONS: The results from this investigation were significantly different from the previous study, which was conducted near sea level. The exact causes for the discrepancies between the portable ASV results from the two studies are unclear, but are thought to be related to differences in blood chemistry between the Midwestern United States and Peruvian Andes worker cohorts. Portable ASV blood lead measurements from populations living at high altitudes should be viewed with caution. Am. J. Ind. Med. 46:656-662, 2004. Published 2004 Wiley-Liss, Inc.

Adult↗

Comparison of capillary earlobe and venous blood monitoring for occupational lead surveillance.

Biological monitoring for occupational lead exposure involves routine venous blood draws from exposed employees. This uncomfortable procedure normally yields more blood than what is needed for analysis. Capillary blood sampling is less invasive but introduces the possibility of surface contamination. The objective of this study was to compare venous and capillary (earlobe) blood lead samples obtained from occupationally exposed individuals. Phlebotomists trained specifically in the collection of blood samples for lead determination collected 2 venous blood samples and 2 capillary earlobe samples from each participating employee. Before the capillary draw, the employee's earlobe was cleansed with an alcohol wipe in an effort to remove potential lead contamination. A second alcohol wipe was then used to sanitize the lancing area and was retained for lead analysis. Both the venous and capillary samples were subsequently analyzed with the use of graphite furnace atomic absorption spectrometry (GFAAS). GFAAS of venous blood specimens was considered the reference method of sampling and analysis. We collected and analyzed 126 paired earlobe and venous samples. Earlobe sampling was preferred to venous sampling by 54% of the employees surveyed. The mean difference between the capillary and venous results was 38.8 +/- 48.1 microg/dL. Lead concentrations in earlobe blood were more than twice those found in venous samples in more than half of the samples (64 of 126). Despite simple cleansing with an alcohol wipe and no visible skin contamination, 94% of the wipe samples from earlobes contained more than 1 microg of lead. Even low concentrations of contamination can significantly alter the concentration of lead in the blood; for example, sample contamination of 0.3 microg lead in a 200-microL blood sample would yield an increase of 150 microg/dL in the measured lead concentration. The findings of this study suggest that until satisfactory skin cleansing and decontamination techniques are identified and evaluated, earlobe sampling should be avoided in the surveillance of occupational blood lead levels.

Adult↗

Field method for the determination of insoluble or total hexavalent chromium in workplace air.

National Institute for Occupational Safety and Health method 7703 is a portable field procedure for the analysis of workplace air filter samples for hexavalent chromium (CrVI) content immediately after the samples are collected. The field method prescribes CrVI extraction from air filter samples with an ammonium sulfate/ammonium hydroxide extraction buffer using ultrasonic extraction (UE). Strong anion-exchange solid-phase extraction (SAE-SPE) is then used to separate CrVI from trivalent chromium and other interferences. Portable spectrophotometric measurement of CrVI is then conducted using the 1,5-diphenylcarbazide (DPC) method. However, it has been found that the ammonium extraction buffer does not adequately bring insoluble CrVI compounds into solution during the UE process. Thus, it was deemed necessary to modify the field method so that it would provide acceptable recoveries for insoluble CrVI compounds. To this end, a more alkaline extraction solution--sodium carbonate/sodium bicarbonate buffer--was investigated. The modified procedure using the highly alkaline extraction solution was demonstrated to be compatible with SAE-SPE cartridges when determining insoluble CrVI in air filter samples. It was found that the carbonate/bicarbonate buffer was equally effective for complete dissolution of both insoluble and soluble forms of CrVI. Furthermore, the modified procedure met desired performance criteria established for air sampling and analytical methods.

Air Pollution, Indoor↗

Developments in electrochemical sensors for occupational and environmental health applications.

This paper provides an overview of recent advances in electrochemical sensors for industrial hygiene monitoring applications. Currently available instrument technologies as well as new devices under development are both exemplified. Progress in ruggedization and miniaturization of electroanalytical devices has led to significant improvements for on-site monitoring applications, e.g. in harsh environments and in biological monitoring. Sensor arrays and modified electrodes offer considerable promise for improved electrochemical sensing, i.e. through multi-species detection and enhanced selectivity. On-site electroanalytical detection and measurement in the field may become more widely used for applications in occupational health monitoring.

Electrochemistry↗

Evaluation of two portable lead-monitoring methods at mining sites.

Two methods for measuring airborne lead using field-portable instruments have been developed by the National Institute for Occupational Safety and Health (NIOSH): Method 7702 uses X-ray fluorescence (XRF), and Method 7701 employs ultrasonic extraction (UE) followed by anodic stripping voltammetry (ASV). The two portable methods were evaluated at mining sites. Area air samples were collected throughout two mills where ore from nearby mines was processed; the primary constituent of the ore was lead sulfide (galena). The air samples were collected on 37 mm mixed cellulose ester membrane filters housed within plastic filter cassettes. At the end of the work shift, the cassettes were collected and taken to a room off-site for analysis by the two portable methods. The filter samples were first analyzed by XRF and then by UE/ASV. Calibration was verified on both instruments according to standard procedures. The samples were then sent for confirmatory analysis via flame atomic absorption spectrometry (FAAS) according to NIOSH Method 7082. Pairwise comparisons between the methods using the paired t-test showed no statistically significant differences between ASV and FAAS (P>0.05); however, the comparison between XRF and FAAS was statistically significant (P<0.05). The elevated lead concentrations reported by XRF relative to FAAS were likely the result of the ability of XRF to report total lead, including lead silicates. This form of lead is not liberated in the digestion process prior to FAAS analysis, and is therefore not detected by this method. Despite this discrepancy, lead concentrations measured by both portable technologies were found to be highly correlated with the laboratory method (R2>0.96), suggesting that they are suitable as screening methods for airborne lead at mining sites.

Air Pollutants↗

Sampling and analysis considerations for the determination of hexavalent chromium in workplace air.

Airborne hexavalent chromium (Cr[VI]) is a known human respiratory carcinogen and allergen. Workers in a variety of industries may be exposed to airborne hexavalent chromium, with exposures frequently occurring via inhalation and/or dermal contact. Analytical methods for the measurement of Cr(VI) compounds in workplace samples, rather than for the determination of total elemental chromium in workplace air, are often desired because exposure limit values for Cr(VI) compounds are much lower than for total Cr. For years, sampling and analytical test methods for airborne Cr(VI) have been investigated so as to provide means for occupational exposure assessment to this highly toxic species. Inter-conversion of trivalent chromium (Cr[III]) and Cr(VI) can sometimes occur during sampling and sample preparation, and efforts to minimize unwanted redox reactions involving these chromium valences have been sought. Because of differences in toxicity, there is also interest in the ability to differentiate between water-soluble and insoluble forms of Cr(VI), and procedures that provide solubility information concerning Cr(VI) compounds have been developed. This paper reviews the state of the art concerning the measurement of airborne Cr(VI) compounds in workplace aerosols and related samples.

Air Pollution, Indoor↗

Field measurement of lead in workplace air and paint chip samples by ultrasonic extraction and portable anodic stripping voltammetry.

On-site measurement of lead in workplace air filter samples and paint chip samples by ultrasonic extraction and anodic stripping voltammetry (UE-ASV) was evaluated in the field during renovation and remodeling activities in residences having leaded paint. Aerosol and paint samples were collected using standard techniques, and the samples were analyzed on-site for lead content by portable UE-ASV. Lead in sample extracts was subsequently determined by atomic absorption (AA) spectrometry in a fixed-site laboratory. The remaining sample extracts plus undissolved material (air filters or paint particles) were then subjected to hot plate digestion in concentrated nitric acid-30% hydrogen peroxide prior to AA analysis for lead. Field UE-ASV lead data were thereby compared to UE-AA and hot plate digestion-AA results from fixed-site laboratory lead measurement. Determination of lead in air filter samples by UE-ASV (over the range of 5 microg to approximately 800 microg Pb per sample) was extremely well correlated with lead measurement by UE-AA and hot plate digestion-AA procedures. However, a significant negative bias associated with ASV measurement was observed, and this was attributed to a matrix effect. Lead measurement in paint chip samples by UE-ASV (over the range of approximately 10 to approximately 550 microg Pb g(-1)) was well correlated with lead measurement by UE-AA and hot plate digestion-AA procedures. However, correlation and precision were lower for lead measurement in paint samples as compared to aerosol samples, and a negative bias was also observed. Lead measurements by UE-AA were compared to lead determinations by hot plate digestion-AA; these data were highly correlated and demonstrated no significant bias. Thus it was concluded that the ultrasonic extraction procedure performed equivalently to hot plate digestion. It was reasoned that matrix effects due to the preparation and analysis of paint chip particles resulted in greater imprecision as well as negative bias by ASV measurement. Despite significant negative bias in this sample set, UE-ASV offers promise for on-site measurement of lead in samples of interest in occupational and environmental health.

Air Pollution, Indoor↗