PubMed Health⌕ Search

Biomedical subjects

Kevin C Chen

Publications and source records attributed to Kevin C Chen.

10 recordsLinked to original sources

Effects of tissue trauma on the characteristics of microdialysis zero-net-flux method sampling neurotransmitters.

Microdialysis has been used for studying neurochemistry in brain regions that respond to afferent inputs or administered drugs. As the knowledge derived from and concerning microdialysis grows, so do the concerns over its invasiveness and, hence, the credibility of resulting data. Recent experimental and theoretical studies impugned the validity of the microdialysis zero-net-flux (ZNF) method in measuring brain extracellular neurotransmitters, suggesting that the tissue trauma resulting from probe implantation seriously compromises its worth. This paper developed a theoretical model to study the influences of two categories of tissue trauma on microdialysis ZNF operation: (1) morphological alterations in tissue extracellular structure and (2) physiological impairment of neurotransmitter release and uptake processes. Model results show that alterations of tissue extracellular structure negligibly affect the accuracy of the ZNF method in determining the basal level of extracellular neurotransmitter but do affect the fundamental characteristics of microdialysis: the extraction efficiency and relative recovery. An inhibited or damaged neurotransmitter uptake process always decreases the efficiency of microdialysis extraction, but rise of the relative recovery of neurotransmitters with the same uptake inhibition/damage occurs only when there is far more damage to the neurotransmitter release than to the uptake process in the tissue. A criterion for this rising trend of microdialysis relative recovery is discussed in terms of trauma parameters and neurotransmitter uptake inhibition.

Brain Injuries↗

Preferentially impaired neurotransmitter release sites not their discreteness compromise the validity of microdialysis zero-net-flux method.

Intracerebral microdialysis is a popular technique for studying neurochemistry and neural circuits in various brain regions. Recent studies called into question the validity of the microdialysis zero-net-flux (ZNF) method by suggesting that this method significantly underestimates the basal level of extracellular dopamine as a result of the discreteness of dopamine release sites as well as the preferential damage to dopamine release over uptake. To identify which factor is most important in undermining the microdialysis ZNF measurements and the extent of underestimation, two mathematical models were developed to explore the influences of the discrete nature and the probe-induced impairment in the neurotransmitter release. The two models differ in their characterizations of the transmitter release as spatially discrete and homogeneous, respectively. Simulations using physiologically reasonable parameters for striatal dopamine systems indicate that the preferential release site damage surrounding the implanted probe is the most important determinant to the underestimation of the microdialysis ZNF concentration. Under normal physiological conditions, the discreteness of neurotransmitter release sites is of minor importance, except when neuronal degeneration occurs. It is concluded that homogeneous models can adequately describe microdialysis operating processes as long as the corresponding tissue damage parameters in such models are appropriately incorporated.

Dopamine↗

Evidence on extracellular dopamine level in rat striatum: implications for the validity of quantitative microdialysis.

Microdialysis zero-net-flux (ZNF) method is commonly used to monitor drug-induced changes in neurotransmitter baseline and release/uptake processes. Recent studies in this field suggest that microdialysis ZNF method seriously underestimates the resting concentration of extracellular dopamine in the rat neostriatum because probe implantation preferentially damages nearby dopamine release sites and that dopamine uptake inhibition increases the relative recovery of dopamine by microdialysis. This study assessed the validity of these claims by examining current data on extracellular dopamine levels at rest and after drug application obtained by voltammetry, a technique thought to induce less tissue disruption than microdialysis. To obtain the extracellular baseline value for dopamine from the evoked overflow data, we modified the existing dopamine kinetic model to suit both the resting and stimulated circumstances. It was found that dopamine uptake inhibition did in fact decrease the microdialysis relative recovery of dopamine, implying that the average basal extracellular dopamine level is within the range of 7-20 nm in rat striatum. This study concludes that the microdialysis ZNF method indeed underestimates the extracellular dopamine concentration, although not by as much as had been thought. Chronic microdialysis damages both neurotransmitter release and uptake, but it does so in a somewhat relative and proportional way for both processes. Thus the validity of the microdialysis ZNF method is not seriously undermined.

Corpus Striatum↗

Cell balance equation for chemotactic bacteria with a biphasic tumbling frequency.

Alt's three-dimensional cell balance equation characterizing the chemotactic bacteria was analyzed under the presence of one-dimensional spatial chemoattractant gradients. Our work differs from that of others who have developed rather general models for chemotaxis in the use of a non-smooth anisotropic tumbling frequency function that responds biphasically to the combined temporal and spatial chemoattractant gradients. General three-dimensional expressions for the bacterial transport parameters were derived for chemotactic bacteria, followed by a perturbation analysis under the planar geometry. The bacterial random motility and chemotaxis were summarized by a motility tensor and a chemotactic velocity vector, respectively. The consequence of invoking the diffusion-approximation assumption and using intrinsic one-dimensional models with modified cellular swimming speeds was investigated by numerical simulations. Characterizing the bacterial random orientation after tumbles by a turn angle probability distribution function, we found that only the first-order angular moment of this turn angle probability distribution is important in influencing the bacterial long-term transport.

Anisotropy↗

Insensitivity of the microdialysis zero-net-flux method to nonlinear uptake and release processes.

In the microdialysis zero-net-flux (ZNF) method the extraction efficiency is conventionally obtained by linear regression. The linear analysis may become invalid for certain analytes that have nonlinear uptake/release processes in the tissue. To examine this hypothesis, a nonlinear model was used to numerically investigate the nonlinearity of the ZNF plot caused by nonlinear uptake and release processes. Three findings from this analysis are: (i) the ZNF method is markedly insensitive to the nonlinear active processes; (ii) a slow infusion rate or a long probe membrane can suppress the nonlinearity; (iii) the release under autoreceptor control does not affect the slope and linearity of the concentration difference plot. It is concluded that in the nM infusion range, the ZNF method is unable to distinguish whether or not the tissue clearance process is nonlinear. During electrical stimulation, neurotransmitter overflow may cause the microdialysis ZNF method to exhibit nonlinearity.

Diffusion↗

Measurement of diffusion parameters using a sinusoidal iontophoretic source in rat cortex.

A new method was developed to extract diffusion parameters in brain tissue using a sinusoidal iontophoretic point source of tetramethylammonium operated at different frequencies. The resulting steady state oscillating extracellular concentration of this probe molecule was continuously monitored using an ion-selective microelectrode located about 100 microm from the source. Because the probe molecules must diffuse through the extracellular space (ECS), the oscillating concentration at the recording location will develop a phase lag and an amplitude attenuation relative to the sinusoidal source. These two components of the signal can be analyzed to determine the tortuosity factor lambda and the ECS volume fraction alpha. The method also measures the nonspecific clearance rate constant kappa. In brain slices this reflects washout of diffusing molecules. Values of alpha (0.18+/-0.05) and lambda (1.67+/-0.08) obtained from this frequency method in rat cortical slices were similar to those obtained by the real-time iontophoretic method employing a square pulse source. The relative merits of the frequency method compared to the pulse method are discussed.

Animals↗

Quantitative dual-probe microdialysis: evaluation of [3H]mannitol diffusion in agar and rat striatum.

Dual-probe microdialysis was used to study interstitial diffusion in the rat brain. A radiolabelled tracer, (3H]mannitol, was continuously infused at different concentrations via a probe acutely implanted into the striatum of an anaesthetized male rat or into a dilute agar gel. Samples were collected by a second probe placed 1 mm away from the first, and the recovered [3H]mannitol was measured by liquid scintillation counting. In the striatum, the delivery of [3H]mannitol was counteracted by its removal from the extracellular space by passive uptake into cells and clearance into the microcirculation, causing the diffusion profile to approach quasi steady-state levels within 2 h. Diffusion data from brain and agar were analysed using a mathematical model. The apparent (effective) diffusion coefficient for [3H]mannitol was D* = 2.9 x 10(-6) cm2/s, the effective volume fraction alpha* = 0.30 and the clearance rate constant kappa= 2.3 x 10(-5)/s. A tortuosity, lambda = 1.81, and penetration distance r = 4.2 mm, were calculated. We conclude that, using dual-probe microdialysis, parameters reflecting geometric and dynamic tissue properties may be obtained using appropriate mathematical analysis. Quantitative dual-probe microdialysis will be valuable in characterizing interstitial diffusion and the clearance processes underpinning volume transmission in the brain.

Agar↗

Quantitative dual-probe microdialysis: mathematical model and analysis.

Steady-state microdialysis is a widely used technique to monitor the concentration changes and distributions of substances in tissues. To obtain more information about brain tissue properties from microdialysis, a dual-probe approach was applied to infuse and sample the radiotracer, [3H]mannitol, simultaneously both in agar gel and in the rat striatum. Because the molecules released by one probe and collected by the other must diffuse through the interstitial space, the concentration profile exhibits dynamic behavior that permits the assessment of the diffusion characteristics in the brain extracellular space and the clearance characteristics. In this paper a mathematical model for dual-probe microdialysis was developed to study brain interstitial diffusion and clearance processes. Theoretical expressions for the spatial distribution of the infused tracer in the brain extracellular space and the temporal concentration at the probe outlet were derived. A fitting program was developed using the simplex algorithm, which finds local minima of the standard deviations between experiments and theory by adjusting the relevant parameters. The theoretical curves accurately fitted the experimental data and generated realistic diffusion parameters, implying that the mathematical model is capable of predicting the interstitial diffusion behavior of [3H]mannitol and that it will be a valuable quantitative tool in dual-probe microdialysis.

Agar↗

Theory relating in vitro and in vivo microdialysis with one or two probes.

In this paper, we further develop the general theory of microdialysis by extending the linear model of Bungay et al. to provide a theoretical basis for in vitro and in vivo microdialysis. Specifically, we considered the effect of active clearance processes on in vivo microdialysis, and thereby elaborated the theory of Benveniste et al. to endogenous compounds. We examined the use of steady state tissue diffusion resistance with negligible clearance processes to interpret microdialysis data. The influence of the tissue properties on the in vitro and in vivo recoveries in dual-probe microdialysis was analyzed and we simulated the effect of the operating parameters on dual probe microdialysis performance. We estimated that the minimum clearance rate constant detectable by microdialysis in a quasi-steady state is about 5.5 x 10(-5) s(-1). This minimum rate constant establishes a criterion, below which inhibition of the active clearance processes does not show detectable influences on the microdialysis extraction efficiency.

Agar↗

Water compartmentalization and spread of ischemic injury in thick-slice ischemia model.

Water compartmentalization was studied in a thick-slice (1000 microm) model of ischemia by combining water-content measurements with extracellular diffusion analysis. Thick slices bathed in artificial cerebrospinal fluid continually gained water. Total tissue water content was increased by 67% after 6 hours of the incubation. Diffusion measurements using the tetramethylammonium method showed that the extracellular space, typically occupying 20% of brain tissue in vivo, was decreased to 10% at 30 minutes and 15% at 6 hours in both deep and superficial layers of thick slices. Quantification of water compartmentalization revealed that water moved initially from the extracellular space into the cells. Later, however, both compartments gained water. The initial cell swelling was accompanied by dramatic shifts in potassium. An initial rise of extracellular potassium to about 50 mmol/L was measured with a potassium-selective microelectrode positioned in the center of the thick slice; the concentration decreased slowly afterwards. Potassium content analysis revealed a 63% loss of tissue potassium within two hours of the incubation. In thick slices, ionic shifts, water redistribution, and a loss of synaptic transmission occur in both deep and superficial layers, indicating the spread of ischemic conditions even to areas with an unrestricted supply of nutrients.

Animals↗