PubMed Health⌕ Search

Biomedical subjects

Kevin D Altria

Publications and source records attributed to Kevin D Altria.

6 recordsLinked to original sources

Determination of folic acid in tablets by microemulsion electrokinetic chromatography.

A microemulsion electrokinetic chromatography (MEEKC) method has been developed and validated for the determination of folic acid, a water-soluble vitamin, in a commercial tablet formulation. The analysis was performed using a microemulsion containing 0.5% (w/w) ethyl acetate, 1.2% (w/w) butan-1-ol, 0.6% (w/w) sodium dodecyl sulfate, 15% (v/v) 2-propanol and 82.7% (w/w) 10 mmol L(-1) sodium tetraborate aqueous buffer at pH 9.2. Direct UV detection at 214nm led to an adequate sensitivity without interference from sample excipients. For quantitative purposes, niacin was used as internal standard. Acceptable precision (<1.2% relative standard deviation (R.S.D.)), linearity (r = 0.9992; range from 160.0 to 240.0 microg/mL), sensitivity (limit of detection (LOD) = 2.98 microg/mL; limit of quantification (LOQ) = 9.05 microg/mL) and recovery (99.8 +/- 1.8% at three concentration levels) were obtained. Based on the performance characteristics, the proposed methodology was found suitable for the determination of folic acid in tablet formulations.

Chromatography, Micellar Electrokinetic Capillary↗

The use of novel water-in-oil microemulsions in microemulsion electrokinetic chromatography.

We describe the novel use of water-in-oil (W/O) microemulsions to achieve unique separations in microemulsion electrokinetic chromatography (MEEKC). The choice and concentration of the buffer type, surfactant and co-surfactant were all examined and optimized. Separations of a range of neutral and acidic analytes was shown to be markedly different to that obtained by (oil-in-water) O/W MEEKC. Neutral solutes are separated by virtue of their solubility (log P) values in O/W MEEKC with the more water-insoluble solutes migrating last. This separation process does not occur in W/O, as neutral solutes are not separated in order of log P.

Acetophenones↗

Orthogonal separations of nicotine and nicotine-related alkaloids by various capillary electrophoretic modes.

The migration behaviour of nicotine and related tobacco alkaloids was investigated using three different capillary electrophoretic (CE) modes. Novel separations were achieved both using microemulsion electrokinetic chromatography (MEEKC) and nonaqueous CE (NACE). Improved resolution compared to previous studies was obtained using free-solution CE (FSCE). Each technique resulted in different, orthogonal separation selectivity. The suitability of each method for application to the analysis of nicotine lozenges is discussed. The FSCE method was applied to the analysis of nicotine lozenges due to its compatibility with an established lozenge extraction solvent. The method used gave good injection precision and linearity. Good agreement of CE and high-performance liquid chromatography (HPLC) results was obtained. The CE method is therefore considered suitable for the quantitative determination of nicotine in nicotine lozenges.

Alkaloids↗

An initial assessment of the use of gradient elution in microemulsion and micellar liquid chromatography.

Novel microemulsion and micellar HPLC separations have been achieved using gradient elution and columns packed with reverse phase material. Initial attempts at gradient microemulsion liquid chromatography proved impossible on use of a microemulsion successfully used in capillary electrophoresis. Optimisation of the microemulsion composition allowed the generation of stable microemulsions to achieve separations in HPLC. The novel use of organic-solvent micellar chromatography in gradient elution mode was shown to give efficient separations. A range of efficient separations of pharmaceuticals and related impurities were obtained. Acidic, basic, and neutral solutes were resolved covering a wide range of water solubilities and polarities. Elution times were in the order of 4-15 minutes. Separations were briefly compared to those accomplished with a micellar HPLC system. It is proposed that gradient elution in both microemulsion and micellar HPLC can be regarded as a highly successful means of achieving resolution of complex mixtures and should be considered for routine analysis and further investigation.

Chromatography, High Pressure Liquid↗

Background and operating parameters in microemulsion electrokinetic chromatography.

Microemulsion electrokinetic chromatography (MEEKC) is an electrodriven separation technique. Separations are generally achieved using microemulsions consisting of surfactant-coated nanometer-sized oil droplets suspended in aqueous buffer. A cosurfactant such as a short-chain alcohol is generally used to stabilize the microemulsion. This review summarizes the various microemulsion types and compositions that have been used in MEEKC. The effects of key-operating variables such as surfactant type and concentration, cosurfactant type and concentration, buffer pH and type, oil type and concentration, use of organic solvent and cyclodextrin additions, and temperature are described. Specific examples of water-in-oil microemulsions and chirally selective separations are also covered.

Chromatography, Micellar Electrokinetic Capillary↗

Microemulsion electrokinetic chromatography.

Microemulsion electrokinetic chromatography (MEEKC) is a CE technique capable of resolving complex mixtures of charged and neutral compounds covering a wide range of solubilities. It is a relatively recently developed technique and the recent increased attention has led to a number of application reports. The background to the technique and a brief overview of reported applications is provided.

Electrophoresis, Capillary↗