Voltage pulses change neural interface properties and improve unit recordings with chronically implanted microelectrodes.

Current neuroprosthetic systems based on electro-physiological recording have an extended, yet finite working lifetime. Some posited lifetime-extension solutions involve improving device biocompatibility or suppressing host immune responses. Our objective was to test an alternative solution comprised of applying a voltage pulse to a microelectrode site, herein termed "rejuvenation." Previously, investigators have reported preliminary electrophysiological results by utilizing a similar voltage pulse. In this study we sought to further explore this phenomenon via two methods: 1) electrophysiology; 2) an equivalent circuit model applied to impedance spectroscopy data. The experiments were conducted via chronically implanted silicon-substrate iridium microelectrode arrays in the rat cortex. Rejuvenation voltages resulted in increased unit recording signal-to-noise ratios (10% +/- 2%), with a maximal increase of 195% from 3.74 to 11.02. Rejuvenation also reduced the electrode site impedances at 1 kHz (67% +/- 2%). Neither the impedance nor recording properties of the electrodes changed on neighboring microelectrode sites that were not rejuvenated. In the equivalent circuit model, we found a transient increase in conductivity, the majority of which corresponded to a decrease in the tissue resistance component (44% +/- 7%). These findings suggest that rejuvenation may be an intervention strategy to prolong the functional lifetime of chronically implanted microelectrodes.

Action Potentials↗

Microstimulation in auditory cortex provides a substrate for detailed behaviors.

Sensory cortical prostheses have potential to aid people suffering from blindness, deafness and other sensory deficits. However, research to date has shown that sensation thresholds via epicortical stimulation are surprisingly large. These thresholds result in potentially deleterious electrical currents, as well as large activation volumes. Large activation volumes putatively limit the corresponding number of independent stimulation channels in a neural prosthesis. In this study, penetrating stimulation of the auditory cortex was tested for its ability to transmit salient information to behaving rat subjects. Here, we show that subjects that were previously trained to discriminate natural stimuli immediately discriminated different microstimulation cues more accurately and with shorter response latencies than the natural stimuli. Additionally, the cortical microstimulation resulted in a generalization gradient across locations within the cortex. The results demonstrate the efficacy of using closely spaced cortical microstimulation to efficiently transmit highly salient and discriminable information to a behaving subject.

Acoustic Stimulation↗

Cortical microstimulation in auditory cortex of rat elicits best-frequency dependent behaviors.

Electrical activation of the auditory cortex has been shown to elicit an auditory sensation; however, the perceptual effects of auditory cortical microstimulation delivered through penetrating microelectrodes have not been clearly elucidated. This study examines the relationship between electrical microstimulus location within the adult rat auditory cortex and the subsequent behavior induced. Four rats were trained on an auditory frequency discrimination task and their lever-pressing behavior in response to stimuli of intermediate auditory frequencies was quantified. Each trained rat was then implanted with a microwire array in the auditory cortex of the left hemisphere. Best frequencies (BFs) of each electrode in the array were determined by both local field potential and multi-unit spike-rate activity evoked by pure tone stimuli. A cross-dimensional psychophysical generalization paradigm was used to evaluate cortical microstimulation-induced behavior. Using the BFs of each electrode, the microstimulation-induced behavior was evaluated relative to the auditory-induced behavior. Microstimulation resulted in behavior that was dependent on the BFs of the electrodes used for stimulation. These results are consistent with recent reports indicating that electrophysiological recordings of neural responses to sensory stimuli may provide insight into the sensation generated by electrical stimulation of the same sensory neural tissue.

Animals↗

Naive coadaptive cortical control.

The ability to control a prosthetic device directly from the neocortex has been demonstrated in rats, monkeys and humans. Here we investigate whether neural control can be accomplished in situations where (1) subjects have not received prior motor training to control the device (naive user) and (2) the neural encoding of movement parameters in the cortex is unknown to the prosthetic device (naive controller). By adopting a decoding strategy that identifies and focuses on units whose firing rate properties are best suited for control, we show that naive subjects mutually adapt to learn control of a neural prosthetic system. Six untrained Long-Evans rats, implanted with silicon micro-electrodes in the motor cortex, learned cortical control of an auditory device without prior motor characterization of the recorded neural ensemble. Single- and multi-unit activities were decoded using a Kalman filter to represent an audio "cursor" (90 ms tone pips ranging from 250 Hz to 16 kHz) which subjects controlled to match a given target frequency. After each trial, a novel adaptive algorithm trained the decoding filter based on correlations of the firing patterns with expected cursor movement. Each behavioral session consisted of 100 trials and began with randomized decoding weights. Within 7 +/- 1.4 (mean +/- SD) sessions, all subjects were able to significantly score above chance (P < 0.05, randomization method) in a fixed target paradigm. Training lasted 24 sessions in which both the behavioral performance and signal to noise ratio of the peri-event histograms increased significantly (P < 0.01, ANOVA). Two rats continued training on a more complex task using a bilateral, two-target control paradigm. Both subjects were able to significantly discriminate the target tones (P < 0.05, Z-test), while one subject demonstrated control above chance (P < 0.05, Z-test) after 12 sessions and continued improvement with many sessions achieving over 90% correct targets. Dynamic analysis of binary trial responses indicated that early learning for this subject occurred during session 6. This study demonstrates that subjects can learn to generate neural control signals that are well suited for use with external devices without prior experience or training.

Action Potentials↗

Repeated voltage biasing improves unit recordings by reducing resistive tissue impedances.

Reactive tissue encapsulation of chronically implanted microelectrode probes can preclude long-term recording of extracellular action potentials. We investigated an intervention strategy for functionally encapsulated microelectrode sites. This method, known as "rejuvenation," involved applying a +1.5 V dc bias to an iridium site for 4 s. Previous studies have demonstrated that rejuvenation resulted in higher signal-to-noise ratios (SNRs) by decreasing noise levels, and reduced 1-kHz site impedances by decreasing the tissue interface resistances. In this study, we have investigated: 1) the duration of a single-voltage bias session and 2) the efficacy of multiple sessions. These questions were addressed through electrophysiological recordings, cyclic voltammetry, and modeling the electrode-tissue interface via an equivalent circuit model fit to impedance spectroscopy data. In the six implants studied, we found SNRs improved for 1-7 days with a peak typically occurring within 24 h of the voltage bias. Root-mean square (RMS) noise of the extracellular recordings decreased for 1-2 days, which paralleled a similar decrease in the adsorbed tissue resistance (Ren) from the model. Implants whose SNR effects lasted more than a day showed stabilized reductions in the extracellular tissue resistance (Rex) and cellular membrane area (Am). Subsequent stimulus sessions were found to drop neural tissue parameters consistently to levels observed immediately after surgery. In most cases, these changes did parallel an improvement in SNR. These findings suggest that rejuvenation may be a useful intervention strategy to prolong the lifetime of chronically implanted microelectrodes.

Action Potentials↗

Single electrode micro-stimulation of rat auditory cortex: an evaluation of behavioral performance.

A combination of electrophysiological mapping, behavioral analysis and cortical micro-stimulation was used to explore the interrelation between the auditory cortex and behavior in the adult rat. Auditory discriminations were evaluated in eight rats trained to discriminate the presence or absence of a 75 dB pure tone stimulus. A probe trial technique was used to obtain intensity generalization gradients that described response probabilities to mid-level tones between 0 and 75 dB. The same rats were then chronically implanted in the auditory cortex with a 16 or 32 channel tungsten microwire electrode array. Implanted animals were then trained to discriminate the presence of single electrode micro-stimulation of magnitude 90 microA (22.5 nC/phase). Intensity generalization gradients were created to obtain the response probabilities to mid-level current magnitudes ranging from 0 to 90 microA on 36 different electrodes in six of the eight rats. The 50% point (the current level resulting in 50% detections) varied from 16.7 to 69.2 microA, with an overall mean of 42.4 (+/-8.1) microA across all single electrodes. Cortical micro-stimulation induced sensory-evoked behavior with similar characteristics as normal auditory stimuli. The results highlight the importance of the auditory cortex in a discrimination task and suggest that micro-stimulation of the auditory cortex might be an effective means for a graded information transfer of auditory information directly to the brain as part of a cortical auditory prosthesis.