PubMed Health⌕ Search

Biomedical subjects

Kevin L Sullivan

Publications and source records attributed to Kevin L Sullivan.

6 recordsLinked to original sources

Infectious complications of implantable venous access devices in patients with sickle cell disease.

PURPOSE: To evaluate the incidence of implantable venous access device infection in patients with sickle cell disease. MATERIALS AND METHODS: The authors performed a retrospective search of their hospital's information system from January 1, 1996 to December 31, 2001 to identify hospital admissions with ICD-9 codes related to sickle cell anemia. This search yielded 2703 admissions in 293 patients. A search of the radiology information system identified 23 of these patients who had placement of an implantable venous access device. Excluding two patients who were lost to follow-up, the population of this study included eight men and 13 women aged 23 to 62 years old (mean, 37 years). A total of 30 implantable venous access devices (25 venous ports, five tunneled catheters) were placed by interventional radiologists. Cases of device infection were identified based on clinical data, microbiology, reports of device removal, and clinical follow-up. Infections were defined according to the Centers for Disease Control criteria for catheter-related bloodstream infection. The incidence of infection, organism, and time from device placement to infection was determined. RESULTS: In 21 patients with 30 devices, 18 device infections (60%) occurred in 12 patients (57%) involving 15 venous ports and three tunneled catheters. There were a total of 12389 days of catheter use and a rate of 1.5 infections per 1000 catheter days. Infections occurred from 16 to 1542 days (mean, 349 days) after device placement. Blood, wound, and catheter tip cultures yielded solitary organisms in 13 cases and mixed organisms in four cases. Staphylococcus aureus was the most common pathogen (59%). One patient was considered infected based on clinical signs and purulent discharge from the port site, despite negative cultures after partial antibiotic treatment. One patient died of sepsis resulting from an infected port. CONCLUSION: This study shows a high incidence of infection associated with placement of implantable venous access devices in patients with sickle cell disease. Therefore, the authors avoid placing these devices in this patient population.

Adult↗

Angiographic assessment of initial balloon angioplasty results.

PURPOSE: To determine the influence of three factors involved in the angiographic assessment of balloon angioplasty-interobserver variability, operator bias, and the definition used to determine success-on the primary (technical) results of angioplasty in the peripheral arteries. MATERIALS AND METHODS: Percent stenosis in 107 lesions in lower-extremity arteries was graded by three independent, experienced vascular radiologists ("observers") before and after balloon angioplasty and their estimates were compared with the initial interpretations reported by the physician performing the procedure ("operator") and an automated quantitative computer analysis. Observer variability was measured with use of intraclass correlation coefficients and SD. Differences among the operator, observers, and the computer were analyzed with use of the Wilcoxon signed-rank test and analysis of variance. For each evaluator, the results in this series of lesions were interpreted with three different definitions of success. RESULTS: Estimation of residual stenosis varied by an average range of 22.76% with an average SD of 8.99. The intraclass correlation coefficients averaged 0.59 for residual stenosis after angioplasty for the three observers but decreased to 0.36 when the operator was included as the fourth evaluator. There was good to very good agreement among the three independent observers and the computer, but poor correlation with the operator (P </= .001). The primary success rates for this series of lesions varied from a low of 47% to high of 99%, depending solely on which definition of success was used. Significant differences among the operator, the three observers, and the computer were not present when the definition of success was based on less than 50% residual stenosis. CONCLUSIONS: Observer variability and bias in the subjective evaluation of peripheral angioplasty can have a significant influence on the reported initial success rates. This effect can be largely eliminated with the use of residual stenosis of less than 50% to define success. Otherwise, meaningful evaluation of angioplasty results will require independent panels of evaluators or computerized measurements.

Analysis of Variance↗

Incidence of central vein stenosis and occlusion following upper extremity PICC and port placement.

The purpose of this study was to determine the incidence of central vein stenosis and occlusion following upper extremity placement of peripherally inserted central venous catheters (PICCs) and venous ports. One hundred fifty-four patients who underwent venography of the ipsilateral central veins prior to initial and subsequent venous access device insertion were retrospectively identified. All follow-up venograms were interpreted at the time of catheter placement by one interventional radiologist over a 5-year period and compared to the findings on initial venography. For patients with central vein abnormalities, hospital and home infusion service records and radiology reports were reviewed to determine catheter dwell time and potential alternative etiologies of central vein stenosis or occlusion. The effect of catheter caliber and dwell time on development of central vein abnormalities was evaluated. Venography performed prior to initial catheter placement showed that 150 patients had normal central veins. Three patients had central vein stenosis, and one had central vein occlusion. Subsequent venograms (n = 154) at the time of additional venous access device placement demonstrated 8 patients with occlusions and 10 with stenoses. Three of the 18 patients with abnormal follow-up venograms were found to have potential alternative causes of central vein abnormalities. Excluding these 3 patients and the 4 patients with abnormal initial venograms, a 7% incidence of central vein stenosis or occlusion was found in patients with prior indwelling catheters and normal initial venograms. Catheter caliber showed no effect on the subsequent development of central vein abnormalities. Patients who developed new or worsened central vein stenosis or occlusion had significantly (p = 0.03) longer catheter dwell times than patients without central vein abnormalities. New central vein stenosis or occlusion occurred in 7% of patients following upper arm placement of venous access devices. Patients with longer catheter dwell time were more likely to develop central vein abnormalities. In order to preserve vascular access for dialysis fistulae and grafts and adhere to Dialysis Outcomes Quality Initiative guidelines, alternative venous access sites should be considered for patients with chronic renal insufficiency and end-stage renal disease.

Adolescent↗

Complications of a percutaneous suture-mediated closure device versus manual compression for arteriotomy closure: a case-controlled study.

PURPOSE: To evaluate the incidence and types of complications encountered with use of a percutaneous suture-mediated closure device versus manual compression for arteriotomy closure in a retrospective case-controlled study. MATERIALS AND METHODS: The authors identified 100 consecutive patients, 15 men and 85 women 21-85 years of age (mean, 50 years), between December 2000 and July 2001 in whom the Closer percutaneous suture-mediated closure device was used during 65 uterine artery embolization (UAE) procedures, 11 hepatic chemoembolization procedures, nine diagnostic angiography procedures, seven peripheral vascular interventions, six visceral arterial interventions, and two thrombolysis procedures. An age-, sex-, and procedure-matched control population was identified in which manual compression was performed. Procedure reports and clinical charts were reviewed for the presence of puncture-site complications, as categorized according to Society of Interventional Radiology reporting standards, and for risk factors and comorbid conditions (hypertension, diabetes, stroke, smoking, and coronary artery disease). Follow-up visits and imaging studies were reviewed for patients with complications. RESULTS: In the Closer group, there were seven device failures, four minor complications, and three major complications. Minor complications included two groin hematomas and two cases of persistent pain at the arteriotomy site. Three major complications consisted of two cases of external iliac artery dissection, one with distal embolization, and one case of common femoral artery (CFA) occlusion and distal embolization. All major complications occurred in women undergoing UAE. One patient required thromboendarterectomy and patch angioplasty to repair the CFA occlusion, as well as amputation of a gangrenous toe. In the manual-compression group, there was one minor complication (a groin hematoma) and no major complications. There were significantly more complications in the Closer group than in the manual compression group (P =.02). CONCLUSIONS: Significantly more complications were associated with use of a percutaneous suture-mediated closure device than with manual compression for arteriotomy-site hemostasis. Major complications and associated morbidity may be seen with use of percutaneous suture-mediated closure devices. In particular, an unexpectedly high frequency of device-related complications was demonstrated in young women undergoing UAE.

Adult↗

Hepatic artery chemoembolization.

Chemoembolization is a technique that can deliver high concentrations of therapeutic agents directly to the liver for prolonged periods. Considerable experience has been gained in the treatment of hepatocellular carcinoma, where it appears to be a safe procedure that provides survival advantage over conservative therapy. There is much less experience in the treatment of hepatic metastases. Patients with carcinoid, pancreatic islet cell tumor, and sarcoma metastatic to the liver do appear to benefit from chemoembolization. Efficacy in other groups, such as patients with colorectal cancer metastatic to the liver, is less well established, but a recently initiated multicenter trial may resolve this issue.

Antineoplastic Agents↗

Postprocedural aspiration test to predict adequacy of dialysis following tunneled catheter placement.

The objective of the study was to determine if a timed aspiration technique with a 20-ml syringe can be used to predict adequacy of blood flow in tunneled dialysis catheters. Sixteen patients referred for de novo placement or manipulation of failing tunneled hemodialysis catheters had the time it takes to fill a 20-ml syringe with the plunger fully withdrawn measured to the nearest tenth of a second. These measurements were correlated with flow rates recorded in dialysis just prior to (if failed catheter) and in the following dialysis session with adequacy determined as at least 300 ml/min. Syringe-filling time (22 catheters in 16 patients) was plotted against adequacy of dialysis. The mean time to fill a 20-ml syringe was 2.2 sec, with a range of 1.0-4.7 sec. The mean time to fill syringes for catheters with adequate dialysis was 1.7 +/- 0.5 sec, and for inadequate catheters, it was 2.8 +/- 0.8 sec. These differences are statistically significant (p < 0.001). Using a filling time of greater than or equal to 2 sec as a threshold gives the highest sensitivity (100%) for predicting inadequate dialysis while maintaining high specificity (75%). To achieve a specificity of 100%, a 3-sec cutoff would be necessary, but would lead to a sensitivity of only 20%. A simple and objective aspiration technique can be performed at the time of tunneled dialysis catheter placement/manipulation to reasonably predict adequacy of subsequent dialysis.

Adult↗