Migraine with aura following atrial septostomy for pulmonary arterial hypertension.

BACKGROUND: A 34-year-old woman with known familial pulmonary arterial hypertension presented with syncope. Despite medical therapy with an endothelin-receptor antagonist and a phosphodiesterase inhibitor, the patient had NYHA class III symptoms, with exertional dyspnea. Right heart catheterization revealed severe pulmonary hypertension (right atrial pressure 15 mmHg, right ventricular pressure 80/15 mmHg, pulmonary artery pressure 80/35 mmHg, mean pulmonary artery pressure 52 mmHg). The patient underwent balloon atrial septostomy, creating a right-to-left shunt. Although she had no history of headaches or migraine attacks, the patient developed a migraine headache with aura on the third day after the procedure. Migraine attacks recurred for the next 2 days, but symptoms were relieved with simple analgesia. INVESTIGATIONS: Physical examination, electrocardiography, laboratory testing, 6-min-walk test, right heart catheterization, chest radiography, transesophageal echocardiography, transthoracic echocardiography. DIAGNOSIS: Migraine with aura following atrial septostomy. MANAGEMENT: Bosentan, sildenafil, furosemide, spironolactone and warfarin therapy, atrial septostomy, and paracetamol therapy for migraine.

Adult↗

Percutaneous closure of postoperative ventricular septal defects with the Amplatzer device.

The objective of this study was to look at the procedure, the results, and the follow-up of patients who underwent percutaneous closure of a residual ventricular septal defect (VSD) following a surgical closure using the Amplatzer VSD device. Four patients had an original diagnosis of tetralogy of Fallot, two patients had a patch leak following a surgical repair of a VSD, and three patients had a VSD not repaired at the time of surgery. All patients fulfilled the currently accepted surgical criterion for reoperation (Qp/Qs>1.5). The mean Qp/Qs was 1.8+/-0.3 (1.5-2.3). Four patients underwent VSD closure using an Amplatzer perimembranous VSD device and in five patients an Amplatzer muscular VSD device was implanted. We performed percutaneous closure in nine patients. The size of the residual shunt ranged from 6 to 14 mm and the size of device used ranged from 8 to 16 mm. The arteriovenous loop needed to be recreated in two patients because of failure to advance the delivery sheath. There was complete closure of the defect in six cases, and a small residual shunt remained in three cases. Percutaneous closure of postoperative VSDs appears to be an effective way to resolve a hemodynamically significant residual shunt. There were no difficulties encountered with implantation of the devices. These promising short-term results need reinforcement with additional long-term data.

Adult↗

Transcatheter closure of perimembranous ventricular septal defects using the amplatzer membranous VSD occluder: immediate and midterm results of an international registry.

OBJECTIVE: To report the immediate and midterm results of transcatheter closure of perimembranous ventricular septal defect (PmVSD) using the Amplatzer membranous VSD occluder (AMVSD). METHODS: Between April 2002 and August 2004, 100 patients underwent an attempt of percutaneous device closure of PmVSD using the AMVSD in 24 international centers. The median age was 9.0 years (0.7-58 years) and the median weight was 27.5 kg (7-121 kg). RESULTS: A device was successfully deployed in 93/100 (93%) patients. Reasons for procedural failure were an increased gradient across the left ventricle outflow tract in one patient, aortic regurgitation in 2 patients, and inability to securely position the device in 4 patients. The median VSD size by TEE was 7.0 mm (1.5-13 mm), median device size 10 mm (4-16 mm) and median fluoroscopy time 22.1 min (8.9-96.0 min). Weight below 10 kg (P = 0.0392), inlet extension of the VSD (P = 0.0139) and aortic cusp prolapse into the VSD (P = 0.0084) were significantly associated with a lower procedural success. Patients have been followed up for a median of 182 days (1-763 days). There were no procedure-related deaths. Complications were encountered in 29/100 (29%) patients, including rhythm or conduction anomalies in 13 patients (two with complete heart block requiring permanent pacemaker implantation), new or increased aortic (9 patients) or tricuspid (9 patients) regurgitation, most of which were classified as trivial or mild. Patients with a weight below 10 kg had a significantly higher incidence of adverse events than patients with a weight above 10 kg (58.3% versus 25.0%, P = 0.0285). Immediately after device release complete closure of the defect was present in 54/93 (58.1%) patients, increasing to 46/55 (83.6%) patients at 6-months follow-up (P = 0.0012). Left ventricle end-diastolic diameter decreased from a median of 44 mm prior to device closure to a median of 39 mm at 6-months postprocedure (P = 0.0015). CONCLUSION: Closure of PmVSDs using the AMVSD occluder is safe and effective. However, longer follow-up period is warranted prior to the wide spread use of this device.

Adolescent↗

Failure of cutting balloon angioplasty to prevent restenosis in childhood pulmonary venous stenosis.

We describe bilateral pulmonary vein stenosis in a 5-year-old boy. He initially presented with haemoptysis secondary to left upper lobe pulmonary vein atresia and left lower lobe stenosis and subsequently he underwent left-sided pneumonectomy. He underwent repeat cardiac catheterizations with repeated balloon angioplasty of the right-sided venous stenoses using a cutting balloon. Despite satisfactory initial results the pulmonary venous stenosis reoccurred as early as 2 months following balloon angioplasty. Although cutting balloon angioplasty has demonstrated effective immediate alleviation of pulmonary venous stenosis its utility in providing sustained improvement in pulmonary vein stenosis is limited.

Angioplasty, Balloon↗

Combined catheter ventricular septal defect closure and multivessel coronary stenting to treat postmyocardial infarction ventricular septal defect and triple-vessel coronary artery disease: a case report.

Ventricular septal defect following acute myocardial infarction is a rare but life-threatening complication. Early surgical closure improves survival but carries a considerable risk. Percutaneous transcatheter closure is an alternative but experience to date is limited. We report a case of successful transcatheter closure of postmyocardial infarction ventricular septal defect (VSD) in a 55-year-old male with the Amplatzer muscular VSD occluder device and complete percutaneous revascularization with successful multivessel coronary stenting for three-vessel disease as a staged procedure. The technique and its potential use as an alternative to surgical approach for treatment of acute myocardial infarction and its complication (VSD) are discussed.