Comparison of usefulness of dipyridamole stress myocardial contrast echocardiography to technetium-99m sestamibi single-photon emission computed tomography for detection of coronary artery disease (PB127 Multicenter Phase 2 Trial results).

We hypothesized that assessment of hyperemic myocardial blood flow (MBF) velocity using myocardial contrast echocardiography (MCE) can detect coronary artery disease (CAD). We also postulated that only a single MCE study during stress is required for the detection of CAD in patients with normal function at rest. Patients with known or suspected CAD referred for dipyridamole stress technetium-99m sestamibi single-photon emission computed tomographic (SPECT) studies were enrolled. MCE was performed concurrently with SPECT using continuous infusions of PB127 during intermittent harmonic power Doppler imaging at multiple pulsing intervals. MCE and SPECT were compared in 43 of 54 patients who had adequate studies using both techniques. In 15 of the 43 patients, coronary angiography was performed within 30 days of the MCE/SPECT tests. Overall concordance for classification of patients as normal versus abnormal was 84% (kappa = 0.63) between the 2 tests. When false-negative SPECT scans were corrected for results of angiography, concordance increased to 93% (kappa = 0.82). For territorial analysis, concordance between MCE and SPECT for location of perfusion defects was 65% (kappa = 0.41) and 74% (kappa = 0.61) after SPECT was corrected by angiography. In patients with normal function at rest, a single stress MCE perfusion study allowed identification of CAD with the same concordance as rest/stress perfusion studies. In conclusion, visual assessment of regional differences in MBF velocity using PB127 allows detection of CAD with good concordance compared with technetium-99m sestamibi SPECT. In patients with normal left ventricular function at rest, a single stress PB127 MCE perfusion study is adequate for the detection of CAD.

Adult↗

Detection of myocardial viability by contrast echocardiography in acute infarction predicts recovery of resting function and contractile reserve.

OBJECTIVES: We sought to determine whether myocardial contrast echocardiography (MCE) performed before and early after primary coronary stenting (PCS) in patients with acute myocardial infarction (AMI) could predict recovery of resting left ventricular systolic function and contractile reserve. BACKGROUND: Myocardial contrast echocardiography can be used to assess perfusion within the risk area before PCS and the extent of necrosis soon after PCS. METHODS: In 30 patients with AMI, MCE and two-dimensional echocardiography were performed before PCS and 3 to 5 days and 4 weeks after PCS. Contractile reserve was assessed by dobutamine echocardiography at four weeks in patients with persistent severe wall-motion abnormalities. RESULTS: Of segments without perfusion at 3 to 5 days, 95% had severe hypokinesis to akinesis at 4 weeks. Of segments with normal perfusion at 3 to 5 days, 90% had normal wall motion or mild hypokinesis at 4 weeks, whereas those with partial perfusion at 3 to 5 days were evenly divided between normal wall motion, hypokinesis, and akinesis. In segments with persistent severe wall-motion abnormalities at four weeks, contractile reserve was found in >80% of segments with perfusion, compared with only 10% of segments without detectable perfusion (p < 0.01). The presence of myocardial perfusion by MCE before PCS was associated with maintained or improved perfusion at 3 to 5 days and eventual recovery of resting wall motion. CONCLUSIONS: Myocardial contrast echocardiography performed early after PCS provides information on the extent of infarction, and hence the likelihood for recovery of resting systolic function or contractile reserve. The presence of perfusion before PCS, from either collateral or antegrade flow, predicts the maintenance of perfusion and recovery of systolic function.

Aged↗

Direct effects of dobutamine on the coronary microcirculation: comparison with adenosine using myocardial contrast echocardiography.

The direct effects of dobutamine on capillary blood volume (VOL) and blood flow velocity (VEL) are not known. We hypothesized that these would be more similar to that of adenosine because of its effects on the beta(2) receptors on the coronary circulation. A total of 9 open-chest anesthetized dogs were studied after placement of 2 noncritical stenoses at rest and during separate intracoronary administrations of 5 microg/kg(-1)/min(-1) of adenosine and 2 microg/kg(-1)/min(-1) of dobutamine. VOL and VEL were measured using myocardial contrast echocardiography, wall thickening with 2-dimensional echocardiography, and myocardial blood flow (MBF) with radiolabeled microspheres. Dobutamine increased the rate-pressure product significantly, whereas adenosine had no effect on the rate-pressure product. In the normal myocardium, adenosine had no effect on VOL and increases in MBF were all a result of increases in VEL. Dobutamine also caused mostly an increase in VEL and only a 30% increase in VOL indicating modest capillary recruitment. In the bed with stenosis both drugs attenuated increase in MBF by the same amount, which was associated with an attenuation in the increase in VEL secondary to a 15% increase in capillary resistance because of capillary derecruitment. The MBF-wall thickening relation was described for both drugs by the same function: y = 1 - exp(x) with wall thickening being significantly higher for dobutamine compared with adenosine for each level of MBF. We conclude that the increase in MBF in the normal myocardium with intracoronary dobutamine occurs mostly from an increase in VEL rather than from an increase in VOL. In the bed with a noncritical stenosis, the increases in MBF and VEL are similar for both drugs. Similar to intracoronary adenosine, intracoronary dobutamine also caused capillary derecruitment distal to a noncritical coronary stenosis.

Adenosine↗

Measurement of myocardial blood flow velocity reserve with myocardial contrast echocardiography in patients with suspected coronary artery disease: comparison with quantitative gated Technetium 99m sestamibi single photon emission computed tomography.

BACKGROUND: The ability of high and low mechanical index (MI) imaging methods during myocardial contrast echocardiography (MCE) to assess the physiologic significance of coronary stenoses were compared with technetium 99m sestamibi single photon emission computed tomography (SPECT) in patients. METHODS: Intermittent ultraharmonic imaging (high MI) and power modulation angio (low MI) were performed during continuous infusions of the echo-enhancing contrast agent, Optison, at rest and after dipyridamole stress in 39 patients. Technetium 99m sestamibi SPECT was performed simultaneously. Images from the 3 apical windows were divided into 6 walls. Myocardial blood flow (MBF) velocity and MBF velocity reserve were quantified from pulsing interval versus acoustic intensity MCE curves in each wall using postprocessed images. RESULTS: Approximately 25% of the myocardial walls could not be analyzed from MCE because of artifacts. MBF velocity and MBF derived from both MCE methods increased significantly after dipyridamole in healthy patients (n = 143 and 129 walls for high and low MI, respectively), compared with those with either reversible (n = 11 and 10 walls for high and low MI, respectively) or fixed defects (n = 18 and 14 walls for high and low MI, respectively) on SPECT. Consequently, MBF velocity and MBF reserve were significantly greater for patients with normal perfusion. Receiver operator characteristic curves obtained for MBF velocity reserve provided a sensitivity and specificity of 82% and 87%, respectively, for high MI; versus 64% and 96%, respectively, for low MI imaging after uninterpretable images were excluded from analysis. CONCLUSIONS: Both high and low MI MCE imaging techniques can be used to determine the presence of perfusion defects as identified by technetium 99m sestamibi SPECT. Low MI imaging methods have a number of drawbacks that limit its sensitivity compared with high MI techniques.

Aged↗

Approaches to the detection of coronary artery disease using myocardial contrast echocardiography.

In the presence of an epicardial coronary stenosis, changes in microvascular hemodynamics after the administration of pharmacologic stress agents result in a decrease in myocardial blood volume (MBV) from capillary derecruitment. Because capillaries provide the greatest resistance to flow during maximal hyperemias, changes in capillary volume are closely coupled to changes in hyperemic myocardial blood flow (MBF). A wide array of imaging techniques are now available with myocardial contrast echocardiography to assess both the spatial and temporal aspects of myocardial perfusion, providing many options for the detection of coronary stenosis by evaluating changes in MBV, MBF, or both.

Blood Flow Velocity↗

Dobutamine versus dipyridamole for inducing reversible perfusion defects in chronic multivessel coronary artery stenosis.

OBJECTIVES: We hypothesized that, although the effects of dipyridamole and dobutamine on myocardial blood volume (MBV) and mean microbubble velocity (VEL) are different, the magnitude of perfusion deficit during both forms of stress is the same because both drugs unmask abnormal myocardial blood flow (MBF) reserve. BACKGROUND: Both dipyridamole and dobutamine are used clinically as pharmacologic stress agents to induce reversible perfusion defects in patients with chronic coronary artery disease (CAD), but the basis for doing so for dobutamine is not clear. METHODS: Eleven chronically instrumented closed-chest dogs with multivessel coronary stenosis were studied. Hemodynamics, radiolabeled microsphere-derived MBF, and myocardial contrast echocardiography (MCE)-derived myocardial perfusion were measured at rest, after dipyridamole infusion (0.56 mg x kg(-1)), and at peak dobutamine dose (either 30 or 40 microg x kg(-1) x min(-1)). Abnormal beds were defined as those demonstrating an MBF reserve <3 with dipyridamole. RESULTS: In the presence of either drug, MBV increased more in the normal bed than in the abnormal bed, but the increase was higher in both beds with dobutamine than with dipyridamole. The slope of the relationship between MBF reserve and MBV reserve was greater during dobutamine than dipyridamole (p < 0.05). The converse was true for VEL reserve (p < 0.05). Consequently, the relationship between the ratios of either variable, or the product of the two, between the abnormal bed and normal bed was similar for both drugs. CONCLUSIONS: Although the effects of dipyridamole and dobutamine on MBV and VEL are different, both are equally effective in detecting physiologically relevant coronary stenoses on MCE. Both can therefore be used interchangeably with myocardial perfusion imaging for the detection of CAD.

Animals↗

Mechanism of inducible regional dysfunction during dipyridamole stress.

BACKGROUND: We hypothesized that increased myocardial oxygen demand resulting from hypotension and reflex tachycardia unmasking a reduced endocardial myocardial blood flow (MBF) reserve is the mechanism of dipyridamole-induced regional dysfunction in chronic coronary artery disease. METHODS AND RESULTS: Ameroid constrictors were placed around the proximal coronary arteries and their major branches in 15 dogs to create chronic coronary stenosis. Seven days later, radiolabeled microsphere-derived MBF and 2-dimensional echocardiography-derived percent wall thickening (%WT) were measured at rest and after 0.56 mg/kg dipyridamole. Dipyridamole caused an increase (mean, 21%) in the rate-pressure product secondary to reflex tachycardia resulting from mild systemic hypotension. %WT in myocardial segments with an endocardial MBF reserve (dipyridamole/resting MBF) of 1.5 to 2.5 (n=35) did not change after dipyridamole, whereas it decreased in segments with an endocardial MBF reserve of <1.5 (n=30) and increased in those with an endocardial MBF reserve of > or =2.5 (n=45) (P<0.05). Most (80%) segments with endocardial MBF reserve of <1.5 and 14% with an endocardial MBF reserve of 1.5 to 2.5 showed inducible dysfunction after dipyridamole, whereas none of the segments with an endocardial MBF reserve of > or =2.5 showed this finding. A sigmoid relation (y=-6.74/[1+exp (19.9. [x-1.84])]+1.35. x, r=0.93, P<0.0001) was noted between endocardial MBF reserve and Delta%WT. In contrast, neither the epicardial MBF reserve nor the endocardial/epicardial MBF ratio during hyperemia was associated with inducible regional dysfunction. CONCLUSIONS: Increased myocardial oxygen demand resulting from hypotension and reflex tachycardia unmasking a reduced endocardial MBF reserve is the primary mechanism of dipyridamole-induced regional dysfunction in chronic coronary artery disease.

Animals↗

Perfusion versus function: the ischemic cascade in demand ischemia: implications of single-vessel versus multivessel stenosis.

BACKGROUND: We hypothesized that during demand ischemia, abnormal perfusion will precede abnormal function, the spatial extent of perfusion abnormality will be greater than that of functional abnormality, and the spatiotemporal disparity between abnormal perfusion and abnormal function will be more marked in the presence of single-vessel stenosis (SVS) versus multivessel stenosis (MVS). METHODS AND RESULTS: Nine dogs each underwent either SVS or MVS placement. These noncritical stenoses were classified as mild, moderate, or severe on the basis of the transstenotic pressure gradient (10 to 14, 15 to 20, or >20 mm Hg). Dobutamine was infused starting at 10 and reaching 40 microg/kg(-1) x min(-1). Wall thickening (WT) and myocardial perfusion (myocardial contrast echocardiography) were assessed at each stage. Resting perfusion and function were normal in all dogs. In SVS, abnormal perfusion (delayed rate of microbubble replenishment) was seen at the lowest dose of dobutamine irrespective of the stenosis severity, whereas WT abnormality was seen only at high doses of dobutamine and was influenced by the stenosis severity. The spatial extent of abnormal perfusion exceeded that of WT abnormality at all but the highest dobutamine dose. This spatiotemporal discordance between abnormal perfusion and function was significantly less in MVS, where it was possible to identify separate regions with abnormal function at lower doses of dobutamine. CONCLUSIONS: These data support the occurrence of the ischemic cascade during demand ischemia. They also explain the higher sensitivity of abnormal perfusion compared with abnormal function for the detection of coronary stenosis as well as the higher sensitivity of dobutamine echocardiography for MVS compared with SVS.

Animals↗

Detection of noncritical coronary stenosis at rest without recourse to exercise or pharmacological stress.

BACKGROUND: Currently, the detection of noncritical coronary stenoses requires some form of stress. We hypothesized that these stenoses can be detected at rest without recourse to stress by assessing adaptive changes that occur distally in the microcirculation. METHODS AND RESULTS: Phasic changes in myocardial video intensity (VI) were measured at rest with continuous high-mechanical-index (MI) contrast echocardiography in 15 open-chest dogs. Data were acquired at baseline and in the presence of different degrees of noncritical coronary stenosis. In 6 of these dogs, capillary blood volume was also measured at baseline using high-MI intermittent imaging with triggering performed separately at both end diastole and end systole. During continuous high-MI imaging, a significant increase in systolic VI was noted with coronary stenoses that resulted in progressive increases in the systolic/diastolic VI ratio with greater degrees of stenosis (P=0.003), with a mildly quadratic relation noted between the two: y=1.3. 10(-6). x(2)+0.01x+0.32, P<0.001, r=0.76, SEE=0.14. There was no difference in capillary blood volume between end diastole and end systole at baseline. CONCLUSIONS: Capillary blood volume does not change between diastole and systole in vivo. Phasic changes in VI are noted at baseline during high-MI continuous imaging. The systolic component is negligible at baseline but increases with increasing levels of noncritical coronary stenosis because of adaptive changes in the microcirculation distal to the stenosis. Thus, the measurement of phasic changes in myocardial VI has the potential to detect coronary stenosis at rest without recourse to any form of stress.

Animals↗

Assessment of myocardial blood flow and volume using myocardial contrast echocardiography.

The development of new microbubble agents and ultrasound imaging modalities now allows the assessment of myocardial perfusion with echocardiography. Microbubbles also can be administered intravenously as constant infusions, which allows their concentration in blood to reach steady state. If the relation between microbubble concentration and video intensity is within the linear range, then myocardial video intensity will reflect the concentration of microbubbles in that region, which at steady state is the myocardial blood volume. The ability to destroy microbubbles and measure their replenishment into the ultrasound beam provides an opportunity to evaluate microbubble (or red blood cell) velocity. The product of myocardial blood volume and red blood cell velocity represents myocardial blood flow.

Blood Flow Velocity↗

Relation between myocardial oxygen consumption and myocardial blood volume: a study using myocardial contrast echocardiography.

Myocardial blood volume (MBV) is the volume of blood residing in myocardial vessels, 90% of which is in capillaries. MBV can be measured in vivo using myocardial contrast echocardiography (MCE). It has been shown that when increases in coronary blood flow (CBF) are not associated with increase in myocardial oxygen consumption (MVO(2)), MBV does not increase. We hypothesized that MBV would increase when increases in CBF are associated with an increase in MVO(2). The atrioventricular node was ablated in 18 dogs and dual-chamber pacing was instituted. In group 1 dogs (n = 9), heart rate was altered from 50 to 150 bpm(-1) in increments of 20 bpm(-1) in random order. In group 2 dogs (n = 9), heart rate was kept constant, and dobutamine was infused at doses of 5, 10, 20, 30, and 40 microg/kg(-1)/min(-1). During each intervention, hemodynamic parameters and MVO(2) were measured, and MCE was performed. MVO(2) increased more (P <.01) with inotropic compared with chronotropic stimulation, resulting in a parallel increase in CBF. MBV fraction and MCE-derived myocardial blood flow increased significantly with increases in MVO(2) (P <.05 and P <.001, respectively) when dobutamine was infused, but remained unchanged when heart rate alone was increased. We conclude that when MVO(2) is increased substantially, the resulting increase in CBF and MCE-derived myocardial blood flow is mediated, in part, by an increase in MBV. Thus, capillary recruitment plays an important role in the physiologic regulation of CBF. Lack of increase in MBV during dobutamine stress may indicate the presence of coronary stenosis or microvascular disease.

Animals↗

Assessment of the vascularity of a left ventricular mass using myocardial contrast echocardiography.

In addition to a thrombus, an intracardiac mass lesion can represent a primary cardiac tumor, or a metastatic lesion to the heart. The echocardiographic appearance and location of the mass, as well as the associated clinical scenario provide useful clues regarding cause, but these echocardiographic features alone may not always be diagnostic. Because most benign cardiac tumors are relatively avascular, the vascularity of a mass may be a feature that can help differentiate benign from malignant tumors. We present a case of a patient with a history of malignant melanoma who was found incidentally to have a cardiac mass on echocardiography. Contrast echocardiography (CE) was used to evaluate the vascularity of the mass. This case is compared with another patient with an apical thrombus, which represents an "avascular" intracardiac structure.

Albumins↗

Imaging of Myocardial Perfusion with SonoVuetrade mark in Patients with a Prior Myocardial Infarction.

Myocardial contrast echocardiography (MCE) is an evolving noninvasive imaging technique that can be used to assess regional myocardial perfusion. MCE relies upon the detection of nonlinear ultrasound signal from gas-filled microbubbles during their microvascular transit, resulting in tissue opacification. Provided that the relation between myocardial microbubble concentration and video intensity (VI) is within the linear range, VI measured from any myocardial region reflects the relative tissue concentration of microbubbles, which is influenced by three factors: (1) microbubble concentration in blood; (2) the myocardial blood volume fraction; and (3) microbubble destruction that occurs within the ultrasound beam. In this article, we discuss how these three factors may influence myocardial perfusion information provided by MCE and highlight the importance of image processing. In order to illustrate these concepts, we examine data obtained during perfusion imaging in patients with prior myocardial infarction using intermittent harmonic imaging at various ultrasound pulsing intervals (PIs) during bolus and continuous venous infusions of a second-generation microbubble agent (SonoVue(trade mark)). Our results suggest that evaluation of resting perfusion is most accurate when both myocardial blood volume and blood velocity are assessed. This information is provided only with continuous infusions of microbubbles during imaging protocols that vary the ultrasound PI.

Journal Article↗