PubMed Health⌕ Search

Biomedical subjects

Kim H Manwaring

Publications and source records attributed to Kim H Manwaring.

3 recordsLinked to original sources

Endoscopic aqueductoplasty and interventriculostomy for the treatment of isolated fourth ventricle in children.

OBJECTIVE: There are different approaches for the treatment of isolated fourth ventricle in children, including a suboccipital ventriculoperitoneal shunt, suboccipital craniotomy with microsurgical fenestration, and endoscopic fenestration. We discuss the indications, surgical methods, and outcome of 18 patients who underwent endoscopic treatment for isolated fourth ventricle. METHODS: We retrospectively reviewed the medical histories of 18 patients with an isolated fourth ventricle. Surgical procedures included endoscopic aqueductoplasty, endoscopic aqueductoplasty with a stent, endoscopic interventriculostomy (lateral ventricle or third ventricle to fourth ventricle), and endoscopic interventriculostomy with a stent. Operations were performed between July 1997 and June 2002. The mean age of the patients at the time of surgery was 3 years. The mean follow-up was 29 months. All patients had a supratentorial ventriculoperitoneal shunt. RESULTS: Clinical symptoms (impairment of consciousness, tetraparesis, and ataxia) improved in all patients. Reduction of the size of the fourth ventricle was observed in all patients. Seven patients required reoperation because of restenosis (39% revision rate). Restenosis occurred between 2 weeks and 7 months after surgery (average, 3 mo). Four patients underwent reoperation with stent placement, and three patients underwent reaqueductoplasty. We had the following complications: one infection, one asymptomatic subdural hygroma, one transient oculomotor paresis, and one permanent oculomotor paresis (4 [22%] of 18 patients). CONCLUSION: The significant failure rate of fourth ventricle shunts has led to the development of alternative treatment methods. Endoscopic aqueductoplasty or interventriculostomy presents an effective, minimally invasive, and safe procedure for the treatment of isolated fourth ventricle in pediatric patients. Compared with suboccipital craniotomy and microsurgical fenestration, endoscopic aqueductoplasty is less invasive, and compared with fourth ventricle shunts, it is more reliable and effective.

Adolescent↗

Implementation, calibration and accuracy testing of an image-enhanced endoscopy system.

This paper presents a new method for image-guided surgery called image-enhanced endoscopy. Registered real and virtual endoscopic images (perspective volume renderings generated from the same view as the endoscope camera using a preoperative image) are displayed simultaneously; when combined with the ability to vary tissue transparency in the virtual images, this provides surgeons with the ability to see beyond visible surfaces and, thus, provides additional exposure during surgery. A mount with four photoreflective spheres is rigidly attached to the endoscope and its position and orientation is tracked using an optical position sensor. Generation of virtual images that are accurately registered to the real endoscopic images requires calibration of the tracked endoscope. The calibration process determines intrinsic parameters (that represent the projection of three-dimensional points onto the two-dimensional endoscope camera imaging plane) and extrinsic parameters (that represent the transformation from the coordinate system of the tracker mount attached to the endoscope to the coordinate system of the endoscope camera), and determines radial lens distortion. The calibration routine is fast, automatic, accurate and reliable, and is insensitive to rotational orientation of the endoscope. The routine automatically detects, localizes, and identifies dots in a video image snapshot of the calibration target grid and determines the calibration parameters from the sets of known physical coordinates and localized image coordinates of the target grid dots. Using nonlinear lens-distortion correction, which can be performed at real-time rates (30 frames per second), the mean projection error is less than 0.5 mm at distances up to 25 mm from the endoscope tip, and less than 1.0 mm up to 45 mm. Experimental measurements and point-based registration error theory show that the tracking error is about 0.5-0.7 mm at the tip of the endoscope and less than 0.9 mm for all points in the field of view of the endoscope camera at a distance of up to 65 mm from the tip. It is probable that much of the projection error is due to endoscope tracking error rather than calibration error. Two examples of clinical applications are presented to illustrate the usefulness of image-enhanced endoscopy. This method is a useful addition to conventional image-guidance systems, which generally show only the position of the tip (and sometimes the orientation) of a surgical instrument or probe on reformatted image slices.

Adolescent↗

A study of family head shape: environment alters cranial shape.

A change in the type of cranial deformities (plagiocephaly) presenting to certain clinics has occurred. The purpose of this study was to compare infant head shapes against head shapes of their biologic parents to explore the roles of heredity and environment on cranial shape. Standardized family photographs and anthropometric measurements demonstrated that 30% of the infants had cranial widths 2 standard deviations above norm, while 4.6% had widths exceeding 3 standard deviations. Despite a mean age of only 8 months, 11.6% had widths that were already greater than that of 1 parent. These results demonstrate that plagiocephaly has taken on a new configuration, presenting not only with asymmetry, but also with excessive cranial width.

Adult↗