PubMed Health⌕ Search

Biomedical subjects

Kirk Hatfield

Publications and source records attributed to Kirk Hatfield.

10 recordsLinked to original sources

Magnitude and directional measures of water and Cr(VI) fluxes by passive flux meter.

A new configuration of the passive fluxmeter (PFM) is presented that provides for simultaneous measurements of both the magnitude and the direction of ambient groundwater specific discharge qo and Cr(VI) mass flux J(Cr). The PFM is configured as a cylindrical unit with an interior divided into a center section and three outer sectors, each packed with a granular anion exchange resin having high sorption capacity for the Cr(VI) oxyanions CrO4(2-) and HCrO4-. The sorbent in the center section is preloaded with benzoate as the "resident" tracer. Laboratory experiments were conducted in which PFMs were placed in porous packed bed columns, through which was passed a measured volume of synthetic groundwater containing Cr(VI). During the deployment period, some of the resident tracer is depleted while the Cr(VI) is sorbed. The resin was then removed from the four sectors separately and extracted to determine the "captured" mass of Cr(VI) and the residual mass of the resident tracer in each. Cumulative specific discharge, q0t, values were assessed using the residual mass of benzoate retained in the center section. The direction of this discharge theta was ascertained from the mass distribution of benzoate intercepted and retained in the outer three sections of the PFM. Cumulative chromium fluxes, J(Cr)t, were quantified using the total Cr(VI) mass intercepted and retained on the PFM. Experiments produced an average measurement error for direction theta of 3 degrees +/- 14 degrees, while the average measurement errors for q0 and J(Cr) were, respectively, -8% +/- 15% and -12% +/- 23%. Results demonstrate the potential utility of the new PFM configuration for characterizing groundwater and contaminant fluxes.

Chromium↗

Inverse characterization of NAPL source zones.

This work presents a possible tool for inverse characterization of NAPL (nonaqueous phase liquid) source zones in terms of contaminant mass flux. A hybrid solution technique was applied that considers contaminant transport through a vertical flux plane. The hybrid solution technique takes advantage of the robust solution capabilities of simulated annealing (SA) and the uncertainty estimation capabilities of minimum relative entropy (MRE). The coupled technique (SA-MRE) provides probability density functions and confidence intervals that would not be available from an independent SA algorithm, and they are obtained more efficiently than if provided by an independent MRE algorithm. The SA-MRE method was used to characterize a NAPL source zone that was emplaced in a three-dimensional aquifer model. When dissolution experiments were complete, the aquifer model was excavated, and the distribution of NAPL zones was recorded using digital images of excavation grids. The excavation images were compiled into a three-dimensional representation of the source zone for comparison with and validation of modeling results.

Alkanes↗

Design of quinonoid-enriched humic materials with enhanced redox properties.

The primary goal of this work was to develop quinonoid-enriched humic materials with enhanced redox properties that could be used as potentially effective redox mediators and reducing agents for in situ remediation of soil and aquatic environments. Two different strategies were formulated and tested to derive these materials. The first strategy called for the oxidation of phenolic fragments associated with the humic aromatic core. In a second strategy, polycondensation of these phenolic fragments was carried out with hydroquinone and catechol. The oxidized derivatives and copolymers obtained were characterized using elemental and functional group analyses, and capillary zone electrophoresis. The redox properties were evaluated using ESR spectrometry and reducing capacity determinations. The reducing capacities of copolymers ranged between 1 and 4 mmol/g, which were much higher than the parent material and the oxidized derivatives. Hence, preference should be given to the copolycondensation approach. The quinonoid-enriched humics are nontoxic, water soluble, and resistant to biodegradation; thus, they could be applied as soil amendments to reduce highly mobile oxoanions of heavy metals and radionuclides, or as redox mediators to enhance in situ bioremediation. Otherwise, cross-linked copolymers could be created to serve as inexpensive reductants in permeable reactive barriers designed to remove highly oxidized contaminants from polluted groundwaters.

Electron Spin Resonance Spectroscopy↗

Field-scale evaluation of the passive flux meter for simultaneous measurement of groundwater and contaminant fluxes.

A new method, passive flux meter (PFM), has been developed and field-tested for simultaneously measuring contaminant and groundwater fluxes in the saturated zone at hazardous waste sites. The PFM approach uses a sorptive permeable medium placed in either a borehole or monitoring well to intercept contaminated groundwater and release "resident" tracers. The sorbent pack is placed in a groundwater flow field for a specified exposure time and then recovered for extraction and analysis. By quantifying the mass fraction of resident tracers lost and the mass of contaminant sorbed, groundwater and contaminant fluxes are calculated. Here, we assessed the performance of PFMs at the Canadian Forces Base Borden field site in Ontario, Canada. Two field tests were conducted under imposed groundwater flow fields: (1) radial flow to a well and (2) linear flow in a test channel confined by sheet pile walls on three sides. Both tests demonstrate that the local fluxes measured by PFM and averaged overthe screen interval were within 15% of imposed groundwaterflow and within 30% of measured contaminant mass flux. Patterns in depth variations in groundwater and contaminant fluxes, determined by the PFM approach, allow for site characterization at a higher spatial resolution. These results support the PMF method as a potential innovative alternative for measuring groundwater and contaminant fluxes in screened wells.

Alcohols↗

A hybrid method for inverse characterization of subsurface contaminant flux.

The methods presented in this work provide a potential tool for characterizing contaminant source zones in terms of mass flux. The problem was conceptualized by considering contaminant transport through a vertical "flux plane" located between a source zone and a downgradient region where contaminant concentrations were measured. The goal was to develop a robust method capable of providing a statement of the magnitude and uncertainty associated with estimated contaminant mass flux values. In order to estimate the magnitude and transverse spatial distribution of mass flux through a plane, the problem was considered in an optimization framework. Two numerical optimization techniques were applied, simulated annealing (SA) and minimum relative entropy (MRE). The capabilities of the flux plane model and the numerical solution techniques were evaluated using data from a numerically generated test problem and a nonreactive tracer experiment performed in a three-dimensional aquifer model. Results demonstrate that SA is more robust and converges more quickly than MRE. However, SA is not capable of providing an estimate of the uncertainty associated with the simulated flux values. In contrast, MRE is not as robust as SA, but once in the neighborhood of the optimal solution, it is quite effective as a tool for inferring mass flux probability density functions, expected flux values, and confidence limits. A hybrid (SA-MRE) solution technique was developed in order to take advantage of the robust solution capabilities of SA and the uncertainty estimation capabilities of MRE. The coupled technique provided probability density functions and confidence intervals that would not have been available from an independent SA algorithm and they were obtained more efficiently than if provided by an independent MRE algorithm.

Algorithms↗

Modeling microbial-mediated reduction in batch reactors.

The governing equations that depict microbially-mediated reduction of heavy metals in the subsurface include a system of coupled nonlinear partial differential equations (PDE's) that describe physical (transport), chemical (sorption), and microbial (reduction/oxidation) processes. The existence of nonlinear reaction terms makes numerical simulations more challenging; however, with the advent of time-splitting solution algorithms, nonlinear reaction terms can be isolated from the convective-dispersive components of the governing transport equations and then solved as a coupled system of nonlinear ordinary differential equations (ODE's). In this paper, four methods are evaluated for solving coupled systems of nonlinear ODE's that describe microbially-mediated reduction/oxidation processes. The evaluation involves a series of comparisons of transient simulations of electron donor oxidation, electron acceptor reduction, and microbial biomass accumulation. The methods evaluation is initiated with a comparison of simulation results obtained with the four methods to those generated with an analytical model. Next, laboratory observations, of nitrite consumption by Nitrobacter winogradski in batch reactors are used in a comparison of batch system simulations generated using each of the four methods and BIOKEMOD (biogeochemical kinetic/equilibrium reaction model). The evaluation finds one of the four methods, the quasi-steady-state approximation (QSSA), to be among the most accurate and easiest to implement. Final validation of the QSSA is performed simulating experimental results of microbially-mediated chromium reductions in batch cultures.

Bacteria↗

A direct passive method for measuring water and contaminant fluxes in porous media.

This paper introduces a new direct method for measuring water and contaminant fluxes in porous media. The method uses a passive flux meter (PFM), which is essentially a self-contained permeable unit properly sized to fit tightly in a screened well or boring. The meter is designed to accommodate a mixed medium of hydrophobic and/or hydrophilic permeable sorbents, which retain dissolved organic/inorganic contaminants present in the groundwater flowing passively through the meter. The contaminant mass intercepted and retained on the sorbent is used to quantify cumulative contaminant mass flux. The sorptive matrix is also impregnated with known amounts of one or more water soluble 'resident tracers'. These tracers are displaced from the sorbent at rates proportional to the groundwater flux; hence, in the current meter design, the resident tracers are used to quantify cumulative groundwater flux. Theory is presented and quantitative tools are developed to interpret the water flux from tracers possessing linear and nonlinear elution profiles. The same theory is extended to derive functional relationships useful for quantifying cumulative contaminant mass flux. To validate theory and demonstrate the passive flux meter, results of multiple box-aquifer experiments are presented and discussed. From these experiments, it is seen that accurate water flux measurements are obtained when the tracer used in calculations resides in the meter at levels representing 20 to 70 percent of the initial condition. 2,4-Dimethyl-3-pentanol (DMP) is used as a surrogate groundwater contaminant in the box aquifer experiments. Cumulative DMP fluxes are measured within 5% of known fluxes. The accuracy of these estimates generally increases with the total volume of water intercepted.

Adsorption↗

Controlled release, blind test of DNAPL remediation by ethanol flushing.

A dense nonaqueous phase liquid (DNAPL) source zone was established within a sheet-pile isolated cell through a controlled release of perchloroethylene (PCE) to evaluate DNAPL remediation by in-situ cosolvent flushing. Ethanol was used as the cosolvent, and the main remedial mechanism was enhanced dissolution based on the phase behavior of the water-ethanol-PCE system. Based on the knowledge of the actual PCE volume introduced into the cell, it was estimated that 83 L of PCE were present at the start of the test. Over a 40-day period, 64% of the PCE was removed by flushing the cell with an alcohol solution of approximately 70% ethanol and 30% water. High removal efficiencies at the end of the test indicated that more PCE could have been removed had it been possible to continue the demonstration. The ethanol solution extracted from the cell was recycled during the test using activated carbon and air stripping treatment. Both of these treatment processes were successful in removing PCE for recycling purposes, with minimal impact on the ethanol content in the treated fluids. Results from pre- and post-flushing partitioning tracer tests overestimated the treatment performance. However, both of these tracer tests missed significant amounts of the PCE present, likely due to inaccessibility of the PCE. The tracer results suggest that some PCE was inaccessible to the ethanol solution which led to the inefficient PCE removal rates observed. The flux-averaged aqueous PCE concentrations measured in the post-flushing tracer test were reduced by a factor of 3 to 4 in the extraction wells that showed the highest PCE removal compared to those concentrations in the pre-flushing tracer test.

Environmental Pollutants↗

An exploratory approach to modeling explosive compound persistence and flux using dissolution kinetics.

Recent advances in the description of aqueous dissolution rates for explosive compounds enhance the ability to describe these compounds as a contaminant source term and to model the behavior of these compounds in a field environment. The objective of this study is to make predictions concerning the persistence of 2,4,6-trinitrotoluene (TNT) and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) in solid form both as individual explosive compounds and components of octol, and the resultant concentrations of explosives in water as a result of dissolution using three exploratory modeling approaches. The selection of dissolution model and rate greatly affect not only the predicted persistence of explosive compound sources but also their resulting concentrations in solution. This study identifies the wide range in possible predictions using existing information and these modeling approaches to highlight the need for further research to ensure that risk assessment, remediation and predicted fate and transport are appropriately presented and interpreted.

Azocines↗

Controlled release, blind tests of DNAPL characterization using partitioning tracers.

The partitioning tracer technique for dense nonaqueous phase liquid (DNAPL) characterization was evaluated in an isolated test cell, in which controlled releases of perchloroethylene (PCE) had occurred. Four partitioning tracer tests were conducted, two using an inverted, double five-spot pumping pattern, and two using vertical circulation wells. Two of the four tests were conducted prior to remedial activities, and two were conducted after. Each test was conducted as a "blind test" where researchers conducting the partitioning tracer tests had no knowledge of the volume, method of release, nor resulting spatial distribution of DNAPL. Multiple partitioning tracers were used in each test, and the DNAPL volume estimates varied significantly within each test based on the different partitioning tracers. The tracers with large partitioning coefficients generally predicted a smaller volume of PCE than that expected based on the actual release volume. However, these predictions were made for low DNAPL saturations (average saturation was approximately 0.003), under conditions near the limits of the method's application. Furthermore, there were several factors that may have hindered prediction accuracy, including tracer degradation and remedial fluid interference.

Alcohols↗