Ultrasonic interrogation of tissue vibrations in arterial and organ injuries: preliminary in vivo results.

Soft tissues surrounding vascular injuries are known to vibrate at audible and palpable frequencies, producing bruits and thrills. We report the results of a feasibility study where Doppler ultrasound (US) was used to quantitatively estimate the tissue vibrations after induced trauma in an animal model. A software-programmable US system was used to acquire quadrature-demodulated ensembles of received US echoes bypassing clutter filtering and other conventional Doppler processing stages. The waveforms of tissue velocity surrounding the injury site were then estimated from the clutter data using autocorrelation and analyzed to determine vibration characteristics. Six New Zealand white rabbits and two juvenile pigs were used for the study. The femoral artery of the anesthetized animal was punctured with an 18-gauge needle to model a peripheral arterial trauma, and the liver was surgically exposed and incised to model organ trauma. Two types of oscillatory tissue motion were observed: "vibrations" with high frequency (>50 Hz) and low peak-peak amplitude (<1 microm) and "flutter" with low frequency (<50 Hz) and high peak-peak amplitude (>1 microm). Active bleeding in femoral artery punctures produced tissue vibrations at the frequency of 323 +/- 214 Hz (mean +/- standard deviation, pooled for both rabbits and pigs) and the amplitude of 0.24 +/- 0.15 microm. Active bleeding in liver incisions produced vibrations at the frequency of 120 +/- 47 Hz and the amplitude of 0.33 +/- 0.25 microm. Flutter was observed in punctured arteries at the frequency of 28 +/- 13 Hz the amplitude of 2.92 +/- 1.75 microm, and in incised livers at the frequency of 26 +/- 6 Hz and the amplitude of 1.53 +/- 0.76 microm. In a punctured artery, the vibration frequency and phase of tissue surrounding the artery were highly correlated between neighboring locations in tissue (correlation coefficient = 0.98), and with the flow oscillations in the lumen (correlation coefficient = 0.96). This preliminary study indicates that tissue vibrations could provide additional physiologic information for detecting, localizing and monitoring internal bleeding using US.

Animals↗

Ultrasonic technique for imaging tissue vibrations: preliminary results.

We propose an ultrasound (US)-based technique for imaging vibrations in the blood vessel walls and surrounding tissue caused by eddies produced during flow through narrowed or punctured arteries. Our approach is to utilize the clutter signal, normally suppressed in conventional color flow imaging, to detect and characterize local tissue vibrations. We demonstrate the feasibility of visualizing the origin and extent of vibrations relative to the underlying anatomy and blood flow in real-time and their quantitative assessment, including measurements of the amplitude, frequency and spatial distribution. We present two signal-processing algorithms, one based on phase decomposition and the other based on spectral estimation using eigen decomposition for isolating vibrations from clutter, blood flow and noise using an ensemble of US echoes. In simulation studies, the computationally efficient phase-decomposition method achieved 96% sensitivity and 98% specificity for vibration detection and was robust to broadband vibrations. Somewhat higher sensitivity (98%) and specificity (99%) could be achieved using the more computationally intensive eigen decomposition-based algorithm. Vibration amplitudes as low as 1 mum were measured accurately in phantom experiments. Real-time tissue vibration imaging at typical color-flow frame rates was implemented on a software-programmable US system. Vibrations were studied in vivo in a stenosed femoral bypass vein graft in a human subject and in a punctured femoral artery and incised spleen in an animal model.

Algorithms↗

Ultrasonic vibration dectection with wavelets: preliminary results.

Several arterial disorders are known to cause systolic audio vibrations in tissue: they include stenoses, vasospasm, aneurysms, bleeds and arteriovenous fistulas. High-amplitude vibrations can be discovered with conventional Doppler ultrasound (US) instruments; however, differentiating brief, low-amplitude vibrations from other nonstationary echo sources is difficult. Further, characterizing the frequency and amplitude of vibrations is not feasible with conventional Doppler US. The automated detection and estimation of both the frequency and amplitude of vibrations with durations less than 100 ms and amplitudes of a micrometer or less have remained a signal-processing challenge. These vibrations may be associated with both nonstationary colored noise and strong low-frequency clutter. The normalized continuous Morlet wavelet power-spectrum analysis of quadrature Doppler echoes, followed by a binary hypothesis test for noise, results in simulated detection rates above 99.9%, with 0.1% false alarms for signal-on signal-to-noise ratios (SNRs) as low as one. Two clinical examples are included.

Algorithms↗

Display of spatially-registered Doppler spectral waveforms and three-dimensional vein graft geometry.

A method has been developed to display Doppler spectral waveforms in lower extremity vein grafts in conjunction with 3-D vessel geometry. Doppler spectral waveforms and cross-sectional images of the vein graft are collected with a custom 3-D ultrasound imaging system. Computer processing generates a display of the Doppler sample volumes registered in 3-D space with a surface reconstruction of the vein graft lumen. An interactive computer interface displays spectral waveforms at user-selected sites in the graft. Summary displays combining spectral waveforms, maximum velocity and cross-sectional area provide a pictorial record of the state of the vein graft along its full length. The method is demonstrated for two patient studies, each at two time points after graft revisions. The graphic display of both hemodynamics and geometry allows rapid assessment of vein graft changes over time.

Aged↗

Measurement of anastomosis geometry in lower extremity bypass grafts with 3-D ultrasound imaging.

The attachment sites of lower extremity bypass grafts are known to exhibit a wide range of geometries. Factors that determine the geometry of a given anastomosis include graft material, graft site, native vessel size, graft size and individual patient anatomy. Therefore, it is difficult to specify a standard anastomosis geometry before surgery and difficult to predict the effect of the geometry on long-term graft patency. We have used 3-D ultrasound imaging to study 46 proximal anastomoses of lower limb bypass grafts. We have developed methods to characterize the 3-D geometry of the anastomosis in terms of component sizes and angles. These detailed geometric measurements describe a range of anastomosis geometries and establish standardized parameters across cases that can be used to relate anastomosis geometry to outcome.

Adult↗

Plethysmographic arterial waveform strain discrimination by Fisher's method.

Plethysmography has been used for over 50 years to measure gross change in tissue blood volume. Over the cardiac cycle, perfused tissue initially expands as the blood flow into the arterioles exceeds the flow through the capillary bed. Later in the cardiac cycle, the accumulated blood drains into the venous vasculature, allowing the tissue to return to its presystolic blood volume. Specific features in the plethysmographic waveform can be used to identify normal and abnormal perfusion. We are developing a Doppler strain-imaging technique to measure the local pulsatile expansion and relaxation of tissue analogous to the gross measurement of tissue volume change with conventional plethysmography. A phantom has been built to generate plethysmographic-style strains with amplitudes of less than 0.1% in a tissue-mimicking material. With Fisher's discriminant analysis, it is shown that normal and abnormal plethysmographic-style strains can be differentiated with high sensitivities using the Fourier components of the strain waveforms normalized to compensate for the variance in the strain amplitude estimate.

Arteries↗

Remodeling in peripheral vein graft revisions: serial study with three-dimensional ultrasound imaging.

OBJECTIVE: Remodeling of vein grafts in the lower limb can lead to stenotic lesions that threaten long-term graft patency. Progressive changes in vein graft geometry were measured at sites of repaired stenoses with three-dimensional (3D) ultrasound imaging. METHODS: Ten vein graft revisions with patch angioplasty were followed up for 31 to 47 weeks. Four revisions were at valve sites, and six were at sites of diffuse intimal hyperplasia. Sets of spatially registered two-dimensional (2D) cross-sectional ultrasound images were assembled to create 3D computer models of each vein graft. Cross-sectional area measurements in planes normal to the vessel center axis were calculated from the 3D surface reconstructions. Data sets from serial studies were registered in a common coordinate system, and cross-sectional area measurements were compared at matched sites. RESULTS: Three of the four vein graft revisions at valve sites changed by less than 18%, and one decreased in cross-sectional area by 61%. Five of the six revisions at sites of diffuse intimal hyperplasia demonstrated significant decreases in lumen area ranging from 26% to 61%, and one revision exhibited no significant change in cross-sectional area. Reproducibility of the cross-sectional area measurements derived from the 3D imaging technique was 6.9%. CONCLUSIONS: Sequential area measurements from 3D ultrasound scans demonstrated different remodeling patterns and rates of change among revision sites within the vein grafts. Lumen narrowing documented with 3D scanning was not associated with consistent flow velocity changes on conventional duplex graft surveillance scans.

Adult↗