PubMed Health⌕ Search

Biomedical subjects

Kiyoshi Yaoeda

Publications and source records attributed to Kiyoshi Yaoeda.

9 recordsLinked to original sources

Measurement of intraocular pressure using the NT-4000: a new non-contact tonometer equipped with pulse synchronous measurement function.

PURPOSE: NT-4000 (Nidek Co. Ltd., Gamagori, Japan) is a new non-contact tonometer (NCT) equipped with pulse synchronous measurement function that can measure intraocular pressure (IOP) synchronized with the ocular pulse. The purpose of this study was to evaluate the usefulness of NT-4000 in normal subjects and in patients with glaucoma and ocular hypertension. METHODS: This study included 175 eyes of 175 subjects. Firstly, the IOP was measured using NT-4000 without the pulse synchronous measurement function (NTn). Secondly, the IOP at peak, middle, and trough phases of the pulse signal were measured using NT-4000 with the pulse synchronous measurement function (NTp, NTm, NTt, respectively). Additionally, the IOP was measured with Goldmann applanation tonometer (GT). The coefficient of variation (CV) of three readings in the NCT measurements was used to evaluate the intra-session reproducibility. Statistical comparisons were performed using Wilcoxon signed rank test and one-way analysis of variance with Scheffe's test. Linear regression analysis was used to calculate correlation coefficients. P values less than 0.05 were accepted as statistically significant. RESULTS: The CV of NTn, NTp, NTm, and NTt were 6.4%, 5.5%, 4.9%, and 5.2%, respectively. The CV of NTp, NTm, and NTt were significantly smaller than that of NTn (P = 0.007, P < 0.001, P < 0.001, respectively). NTp was significantly higher than NTt (P = 0.038). GT was significantly correlated with NTn, NTp, NTm, and NTt (r = 0.898, P < 0.001; r = 0.912, P < 0.001; r = 0.908, P < 0.001; r = 0.900, P < 0.001, respectively). CONCLUSION: NT-4000 can detect the fluctuation of IOP associated with the ocular pulse.

Adult↗

Relationship between indices of Humphrey perimetry and Frequency Doubling Technology Perimetry in glaucoma.

PURPOSE: To study whether the correlation between indices of Humphrey perimetry and Frequency Doubling Technology (FDT) perimetry differs in the early and later stages of glaucoma. METHODS: This study included 200 eyes of 200 patients with primary open-angle glaucoma or normal-tension glaucoma. The eyes were classified into the early and later stages by the median value (-4.51 dB) (Classification 1; n = 100 and 100, respectively) or the average value of the maximum and minimum values (-11.90 dB) (Classification 2; n = 165 and 35, respectively) of mean deviation (MD) obtained from a set of measurements with the Humphrey Full-Threshold 30-2 program in all eyes. The correlation between MD (H-MD) or pattern standard deviation (PSD) (H-PSD), as obtained from another set of measurements with the Humphrey Full-Threshold 30-2 program, and MD (F-MD) or PSD (F-PSD), as calculated by the Full-Threshold N-30 program of FDT perimetry, were evaluated using linear regression analysis. RESULTS: Overall, H-MD and H-PSD significantly correlated with F-MD (r = 0.713; P < 0.001) and F-PSD (r = 0.731; P < 0.001), respectively. In each of Classifications 1 and 2, H-MD and H-PSD significantly correlated with F-MD and F-PSD, respectively, both in the early and later stages. However, in each classification, the correlation between H-MD and F-MD differed significantly between the two stages (Classification 1; P < 0.001; Classification 2, P = 0.003), while the correlation between H-PSD and F-PSD did not differ significantly between the two stages. CONCLUSION: The degree of correlation between H-MD and F-MD differed between the early and later stages of glaucoma.

Female↗

Optic disc topography as measured by confocal scanning laser ophthalmoscopy and visual field loss in Japanese patients with primary open-angle or normal-tension glaucoma.

PURPOSE: To determine whether differences in the optic disc topography and those in the relation between the optic disc topography and visual field indices exist between Japanese patients with primary open-angle glaucoma (POAG) and normal-tension glaucoma (NTG). METHODS: The study included consecutive Japanese patients with POAG (n = 60) or NTG (n = 60). Using the Heidelberg Retina Tomograph (HRT), we measured disc area, cup area, cup-to-disc area ratio, rim area, cup volume, rim volume, cup shape measure, and height variation contour. Each HRT parameter was measured in the total optic disc and in its four 90 degree quadrants (superior, temporal, inferior, and nasal). The mean deviation for the entire field and the sum of the total deviation values corresponding to each optic disc quadrant were calculated using the Humphrey full-threshold 30-2 program. RESULTS: No significant differences were found between the POAG and NTG groups for any HRT parameter either globally or regionally. There were no significant differences between the two groups in the correlation coefficients between any HRT parameter and the corresponding visual field indices either globally or regionally. CONCLUSION: No significant differences were apparent between Japanese patients with POAG and NTG both in the optic disc parameters as measured by HRT and in the degree of correlation between HRT parameter and the corresponding visual field indices.

Female↗

Relationship between optic nerve head microcirculation and visual field loss in glaucoma.

PURPOSE: To study the relationship between optic nerve head blood flow velocity and visual field loss in patients with primary open-angle glaucoma (POAG) and normal tension glaucoma (NTG). METHODS: This study included 44 eyes of 44 patients with POAG and 44 eyes of 44 patients with NTG. To evaluate optic nerve head blood flow velocity, the square blur rate (SBR) was measured by means of laser speckle flowgraphy. The correlation between SBR and Humphrey visual field indices was evaluated with linear regression analysis. RESULTS: In the NTG group, the average SBR at the superior and inferior temporal neuroretinal rim was positively correlated with mean deviation (MD) (r = 0.349, p = 0.020). The SBR at the superior or inferior temporal neuroretinal rim was positively correlated with the sum of the total deviations in the corresponding hemifields (r = 0.299, p = 0.049; r = 0.354, p = 0.019, respectively). The correlations between SBR and MD did not differ statistically between the NTG and POAG groups; however, no significant correlation between SBR and visual field indices was observed in the POAG group. CONCLUSION: These results suggested that the change in the circulation of the optic nerve head may be related to visual field damage in the NTG group but may be less involved in visual field damage in the POAG group.

Antihypertensive Agents↗

Localization and expression of chondromodulin-I in the rat cornea.

The localization and expression in the rat cornea of chondromodulin-I (ChM-I), an inhibitory angiogenesis factor, were examined by immunohistochemistry, Western blot analysis, ribonuclease protection assay, and real-time PCR assay. We found immunoreactivity for ChM-I in the epithelial layer but not the stromal layer or endothelial layer in the cornea, in addition to the positive ChM-I immunoreactivity in other sites in the eye such as the sclera, retina, and ciliary body. The ChM-I immunoreactivity was most intense at the outside of the basal cells and in their cytoplasm while the intensity of the immunoreactivity decreased gradually from the wing cells to the superficial cells in the corneal epithelial layer. No reactivity however, was detected in the Bowman's membrane or conjunctival epithelial cells which had continuity with the corneal epithelial cells. The expression of ChM-I mRNA was demonstrated in the cornea at one-third less intensity than that in the sclera with choroids and retinal pigment epithelium by ribonuclease protection assay and real-time PCR. ChM-I in the corneal epithelial layer may prevent neovascularization and maintain avascularity in the cornea.

Animals↗

Expression of the cartilage derived anti-angiogenic factor chondromodulin-I decreases in the early stage of experimental osteoarthritis.

OBJECTIVE: Chondromodulin-I (ChM-I), a cartilage derived anti-angiogenic factor, has been shown to regulate the vascular invasion during endochondral bone formation. We evaluated the expression and localization of ChM-I in articular cartilage during the progression of osteoarthritis (OA) in the rat, and correlated ChM-I expression with the increase in vascular invasion into OA articular cartilage. METHODS: Expression of ChM-I, type II collagen, basic fibroblast growth factor, vascular endothelial growth factor (VEGF), and matrix metalloproteinases MMP-9 and MMP-13 were examined in articular cartilage of intact growing and adult rats and in the surgically induced OA model using in situ hybridization, Western blot analysis, and immunohistochemistry. Co-immunostaining for ChM-I and CD-31 was performed to localize ChM-I and neovascularization in articular cartilage at advanced stage of OA. RESULTS: Abundant expression of ChM-I protein was detected in avascular regions of the developing and adult healthy articular cartilage. In early OA, ChM-I expression decreased in the superficial zone of articular cartilage, while levels of proteoglycan and type II collagen were comparable to control. In advanced OA, ChM-I expression was reduced in all zones of articular cartilage, and the number of VEGF-expressing cells was increased. Immunohistochemical studies showed that vascular invasion occurred in proximity to chondrocytes with high expression of pro-angiogenic markers, and decreased expression of ChM-I. CONCLUSION: High expression of ChM-I was detected in articular cartilage of growing and normal adult joints, implicating its role in the maintenance of avascularity of intact articular cartilage. Expression of ChM-I decreased, while expression of VEGF and other pro-angiogenic factors increased, in OA cartilage. These findings suggest the loss of ChM-I from articular cartilage might be responsible in part for promoting blood vessel invasion into the cartilage during progression of OA.

Angiogenesis Inhibitors↗

Specificity and sensitivity of glaucoma detection in the Japanese population using scanning laser polarimetry.

AIMS: To investigate the usefulness of the scanning laser polarimeter (GDx; GDx Nerve Fiber Analyzer) for glaucoma detection in the Japanese population, and to investigate the difference in the thickness of retinal nerve fibre layer (RNFL) between normal tension glaucoma (NTG) and primary open angle glaucoma (POAG). METHODS: 69 eyes of 69 normal subjects and 115 eyes of 115 chronic open angle glaucoma patients (60 NTG and 55 POAG patients) were studied. The thickness of RNFL was measured with GDx. An eye was diagnosed as glaucomatous, if at least one original GDx variable showed p <5%. The difference in thickness of RNFL between the NTG and POAG groups was then investigated. RESULTS: 46 normal eyes (66.7%) were diagnosed as not glaucomatous (no variables showing p <5%), and 93 glaucomatous eyes (46 NTG and 47 POAG eyes) (80.9%) were diagnosed as glaucomatous. Actual values of average thickness, ellipse average, superior average, and superior integral were significantly lower in the POAG group than those in the NTG group. CONCLUSIONS: New variables which elucidate focal RNFL defects or early changes are needed to improve the moderate detection ability found in this present study. The pattern of the change in RNFL may differ in NTG and POAG groups.

Adult↗

Comparison of fornix- and limbus-based conjunctival flaps in mitomycin C trabeculectomy with laser suture lysis in Japanese glaucoma patients.

PURPOSE: To analyze the results of mitomycin C (MMC) trabeculectomy and laser suture lysis using either fornix-based (FB) or limbus-based (LB) conjunctival flaps. METHODS: Eighty-two Japanese glaucoma patients were treated by MMC trabeculectomy, with 38 eyes receiving an FB conjunctival flap and 44 eyes receiving an LB conjunctival flap. Postoperative intraocular pressure (IOP), the probability of success, and complications were compared between the FB and LB groups. RESULTS: The IOP of the FB group decreased from 21.6+/-7.90 mmHg to 9.75+/-3.23 mmHg at 12 months postoperation, and the IOP of the LB group decreased from 21.3+/-6.77 mmHg to 9.30+/-3.16 mmHg. The postoperative IOPs were similar in the two groups at all postoperative time points. A life-table analysis (Kaplan-Meier method) showed that the survival rate was similar in the two groups but tended to be lower in the early postoperative period in the FB group. Complications were similar also, with the exception of increased leakage in the FB group. CONCLUSIONS: MMC trabeculectomy results were similar between FB and LB conjunctival flaps, in agreement with previous reports. However, increased care may be warranted when an FB flap is used in MMC trabeculectomy.

Antibiotics, Antineoplastic↗

The outcome of mitomycin C trabeculectomy and laser suture lysis depends on postoperative management.

PURPOSE: To verify that postoperative management affects the outcome of mitomycin C (MMC) trabeculectomy and suture lysis. METHODS: A total of 108 eyes in 108 Japanese patients were treated with MMC trabeculectomy. They were divided into two groups based on when the operation was performed: group A, 57 eyes in 1998, and group B, 51 eyes in 2001. The results, including postoperative intraocular pressure (IOP), complications, and postoperative management, were compared between groups. In addition, they were evaluated by a Kaplan-Meier life-table analysis. RESULTS: Postoperative IOP was lower and the probability of success by life-table analysis was higher in group B than in group A. Postoperative management, including laser suture lysis and subconjunctival injection of 5-fluorouracil, was started significantly earlier in group B than in group A patients. Although more postoperative complications occurred in group B, none were severe and all were adequately managed. CONCLUSIONS: Starting postoperative management earlier, particularly laser suture lysis, may be necessary to achieve lower and longer IOP control in MMC trabeculectomy.

Antibiotics, Antineoplastic↗