Radiophotoluminescence dosimetry using a small spherical glass: a preliminary phantom study.

A radiophotoluminescence dosimetry has been proposed using a spherical silver-activated phosphate glass with a diameter of 1.5 mm. A 6 MV photon dose of 2 Sv (2 Gy) was delivered to 14 spherical glass samples placed between two solid water phantoms at a depth of 10 cm. The samples were positioned within a 20 x 20 mm(2) centred at beam axis to ensure uniform dose absorption. A normalised output from a read-out system was obtained by simultaneously measuring luminescence from a non-irradiated reference and that from an irradiated reference to eliminate background contamination and time-varying fluctuation of the readout system, leading to a normalised standard deviation of 1.8%. A dose up to 3.5 Sv (3.5 Gy) was delivered to three spherical glass samples positioned between two solid water phantoms at a depth of 10 cm. The normalised output increased linearly with the applied dose.

Luminescent Measurements↗

Patient positioning method based on binary image correlation between two edge images for proton-beam radiation therapy.

A new technique based on normalized binary image correlation between two edge images has been proposed for positioning proton-beam radiotherapy patients. A Canny edge detector was used to extract two edge images from a reference x-ray image and a test x-ray image of a patient before positioning. While translating and rotating the edged test image, the absolute value of the normalized binary image correlation between the two edge images is iteratively maximized. Each time before rotation, dilation is applied to the edged test image to avoid a steep reduction of the image correlation. To evaluate robustness of the proposed method, a simulation has been carried out using 240 simulated edged head front-view images extracted from a reference image by varying parameters of the Canny algorithm with a given range of rotation angles and translation amounts in x and y directions. It was shown that resulting registration errors have an accuracy of one pixel in x and y directions and zero degrees in rotation, even when the number of edge pixels significantly differs between the edged reference image and the edged simulation image. Subsequently, positioning experiments using several sets of head, lung, and hip data have been performed. We have observed that the differences of translation and rotation between manual positioning and the proposed method were within one pixel in translation and one degree in rotation. From the results of the validation study, it can be concluded that a significant reduction in workload for the physicians and technicians can be achieved with this method.

Algorithms↗

Single nucleotide polymorphism detection in aldehyde dehydrogenase 2 (ALDH2) gene using bacterial magnetic particles based on dissociation curve analysis.

Single nucleotide polymorphism (SNP) detection for aldehyde dehydrogenase 2 (ALDH2) gene based on DNA thermal dissociation curve analysis was successfully demonstrated using an automated system with bacterial magnetic particles (BMPs) by developing a new method for avoiding light scattering caused by nanometer-size particles when using commercially available fluorescent dyes such as FITC, Cy3, and Cy5 as labeling chromophores. Biotin-labeled PCR products in ALDH2, two allele-specific probes (Cy3-labeled detection probe for ALDH2*1 and Cy5-labeled detection probe for ALDH2*2), streptavidin-immobilized BMPs (SA-BMPs) were simultaneously mixed. The mixture was denatured at 70 degrees C for 3 min, cooled slowly to 25 degrees C, and incubated for 10 min, allowing the DNA duplex to form between Cy3- or Cy5-labeled detection probes and biotin-labeled PCR products on SA-BMPs. Then duplex DNA-BMP complex was heated to 58 degrees C, a temperature determined by dissociation curve analysis and a dissociated single-base mismatched detection probe was removed at the same temperature under precise control. Furthermore, fluorescence signal from the detection probe was liberated into the supernatant from completely matched duplex DNA-BMP complex by heating to 80 degrees C and measured. In the homozygote target DNA (ALDH2*1/*1 and ALDH2*2/*2), the fluorescence signals from single-base mismatched were decreased to background level, indicating that mismatched hybridization was efficiently removed by the washing process. In the heterozygote target DNA (ALDH2*1/*2), each fluorescence signals was at a similar level. Therefore, three genotypes of SNP in ALDH2 gene were detected using the automated detection system with BMPs.

Aldehyde Dehydrogenase↗

A technique for noninvasive respiratory gated radiation treatment system based on a real time 3D ultrasound image correlation: a phantom study.

This paper proposes a new respiratory gated radiation treatment system that allows real-time tumor localization while avoiding invasive operation to a patient. The proposed system employs a three-dimensional (3D) ultrasound device, a 3D digital localizer, and a real-time image processing system. At the planning time, CT and 3D ultrasound reference data are simultaneously acquired under a breath-hold condition. At the treatment time, ultrasound data on three orthogonal planes are acquired and transferred to the image processing system on a real-time basis. Subsequently, normalized image correlation indices using the reference and the real-time ultrasound data are calculated for the three orthogonal planes after performing real-time coordinate transform using the 3D digital localizer attached to an ultrasound probe. Prior to the system execution, the coordinate transform matrices are partially calculated using an ultrasound calibration phantom and the 3D digital localizer. A trigger pulse to a linac can be generated when the normalized image correlation index exceeds a predetermined threshold level. Experiments have been carried out using a moving-target phantom that simulates a patient respiratory motion. We have observed that the variation of the calculated real-time correlation index synchronizes with the periodical motion of the moving-target, suggesting that real-time localization for a moving tumor is feasible with the proposed system.

Algorithms↗

A multiportal compensator system for IMRT delivery.

We have developed a multiportal compensator system for IMRT delivery, comprising a rotational compensator mount for a linac head, cylindrical compensator enclosures positioned in the mount, a vacuum-formed thermoplastic sheet with heavy alloy granules inside the enclosure, and a vacuum thermoforming device. The mount rotates like a revolver by a stepping motor, thus allowing automatic multiportal IMRT without exchanging compensators by human operators during treatment. The thermoforming device has servo-motor-driven 10 x 10 metal rod elements to actualize an arbitrary intensity profile. The thermoplastic sheet is preheated by a built-in biplanar heater and then it is placed over the rod elements. Subsequently, vacuum forming is performed through corner cutouts of the rod elements. After forced cooling down, the heavy alloy granules are fed into the formed sheet. Preliminary experiment using solid water phantoms and an x-ray film has shown that the intensity profile on the film agrees reasonably well with the desired profile.