Klaas P Pruessmann

Publications and source records attributed to Klaas P Pruessmann.

At least 19 recordsLinked to original sources

k-t BLAST reconstruction from non-Cartesian k-t space sampling.

Current implementations of k-t Broad-use Linear Acqusition Speed-up Technique (BLAST) require the sampling in k-t space to conform to a lattice. To permit the use of k-t BLAST with non-Cartesian sampling, an iterative reconstruction approach is proposed in this work. This method, which is based on the conjugate gradient (CG) method and gridding reconstruction principles, can efficiently handle data that are sampled along non-Cartesian trajectories in k-t space. The approach is demonstrated on prospectively gated radial and retrospectively gated Cartesian imaging. Compared to a sliding window (SW) reconstruction, the resulting image series exhibit lower artifact levels and improved temporal fidelity. The proposed approach thus allows investigators to combine the specific advantages of non-Cartesian imaging or retrospective gating with the acceleration provided by k-t BLAST.

Artifacts↗

Lattice permutation for reducing motion artifacts in radial and spiral dynamic imaging.

Radial and spiral trajectories exhibit favorable characteristics for dynamic imaging. Nevertheless, changes in image contents during acquisition lead to inconsistencies in the k-space data, which are manifested as streaks or spiral artifacts, respectively. This work proposes the concept of lattice permutation to reorder the data segments for artifact suppression. This acts to reshuffle the alias pattern along the temporal frequency axis. The proposed approach is well suited to sliding window reconstruction, although more sophisticated methods are also possible. For typical image series where the signal energies are concentrated in the low temporal frequencies, the permutation displaces most of the aliased signals from the low temporal frequencies to the high temporal frequencies, where they are attenuated by sliding window reconstruction, while the signals in the low temporal frequencies are mostly contaminated by aliasing from the much weaker signals in the higher temporal frequencies. This results in considerably reduced artifacts without any increase in scan time. In practice, lattice permutation achieves similar artifact suppression as the bit-reversed order, but with a less stringent restriction on the number of segments. At the same time, it provides a more powerful approach to controlling the alias pattern exactly. Results from real-time cardiac imaging are demonstrated.

Artifacts↗

Encoding and reconstruction in parallel MRI.

The advent of parallel MRI over recent years has prompted a variety of concepts and techniques for performing parallel imaging. A main distinguishing feature among these is the specific way of posing and solving the problem of image reconstruction from undersampled multiple-coil data. The clearest distinction in this respect is that between k-space and image-domain methods. The present paper reviews the basic reconstruction approaches, aiming to emphasize common principles along with actual differences. To this end the treatment starts with an elaboration of the encoding mechanisms and sampling strategies that define the reconstruction task. Based on these considerations a formal framework is developed that permits the various methods to be viewed as different solutions of one common problem. Besides the distinction between k-space and image-domain approaches, special attention is given to the implications of general vs lattice sampling patterns. The paper closes with remarks concerning noise propagation and control in parallel imaging and an outlook upon key issues to be addressed in the future.

Algorithms↗

Potential and feasibility of parallel MRI at high field.

This survey focuses on the fusion of two major lines of recent progress in MRI methodology: parallel imaging with receiver coil arrays and the transition to high and ultra-high field strength for human applications. As discussed in this paper, combining the two developments has vast potential due to multiple specific synergies. First, parallel acquisition and high field are highly complementary in terms of their individual advantages and downsides. As a consequence, the joint approach generally offers enhanced flexibility in the design of scanning strategies. Second, increasing resonance frequency changes the electrodynamics of the MR signal in such a way that parallel imaging becomes more effective in large objects. The underlying conceptual and theoretical considerations are reviewed in detail. In further sections, technical challenges and practical aspects are discussed. The feasibility of parallel MRI at ultra-high field is illustrated by current results of parallel human MRI at 7 T.

Algorithms↗

Transmit and receive transmission line arrays for 7 Tesla parallel imaging.

Transceive array coils, capable of RF transmission and independent signal reception, were developed for parallel, 1H imaging applications in the human head at 7 T (300 MHz). The coils combine the advantages of high-frequency properties of transmission lines with classic MR coil design. Because of the short wavelength at the 1H frequency at 300 MHz, these coils were straightforward to build and decouple. The sensitivity profiles of individual coils were highly asymmetric, as expected at this high frequency; however, the summed images from all coils were relatively uniform over the whole brain. Data were obtained with four- and eight-channel transceive arrays built using a loop configuration and compared to arrays built from straight stripline transmission lines. With both the four- and the eight-channel arrays, parallel imaging with sensitivity encoding with high reduction numbers was feasible at 7 T in the human head. A one-dimensional reduction factor of 4 was robustly achieved with an average g value of 1.25 with the eight-channel transmit/receive coils.

Brain↗

Sensitivity encoding as a means of enhancing the SNR efficiency in steady-state MRI.

Sensitivity encoding (SENSE) with a receiver coil array is typically used as a means of reducing the scan time in MRI. The speed benefit usually comes at some expense in terms of the signal-to-noise ratio (SNR) efficiency, which has been notorious as the main downside of SENSE and parallel MRI in general. In this work it is shown that in steady-state gradient-echo imaging the parallel approach may as well be used to increase the SNR efficiency. The basic idea is to balance reduced phase encoding by increasing the repetition time. In this fashion both the acquisition duty cycle and the steady-state magnetization can be enhanced, resulting in considerable net gains in SNR yield. It is argued that the reduction factor in parallel imaging is essentially an additional degree of freedom in optimizing the SNR. The optimal SENSE factor depends on scan, tissue, and hardware parameters, assuming values up to 3.0 and higher. The achievable SNR benefit also depends on the spoiling regime and is most pronounced for RF-spoiled techniques. The proposed mechanism is demonstrated by simulations and phantom experiments, as well as by contrast-enhanced angiography in vivo, achieving an approximate doubling of the SNR efficiency.

Computer Simulation↗

Optimizing spatiotemporal sampling for k-t BLAST and k-t SENSE: application to high-resolution real-time cardiac steady-state free precession.

In k-t BLAST and k-t SENSE, data acquisition is accelerated by sparsely sampling k-space over time. This undersampling in k-t space causes the object signals to be convolved with a point spread function in x-f space (x = spatial position, f = temporal frequency). The resulting aliasing is resolved by exploiting spatiotemporal correlations within the data. In general, reconstruction accuracy can be improved by controlling the k-t sampling pattern to minimize signal overlap in x-f space. In this work, we describe an approach to obtain generally favorable patterns for typical image series without specific knowledge of the image series itself. These optimized sampling patterns were applied to free-breathing, untriggered (i.e., real-time) cardiac imaging with steady-state free precession (SSFP). Eddy-current artifacts, which are otherwise increased drastically in SSFP by the undersampling, were minimized using alternating k-space sweeps. With the synergistic combination of the k-t approach with optimized sampling and SSFP with alternating k-space sweeps, it was possible to achieve a high signal-to-noise ratio, high contrast, and high spatiotemporal resolutions, while achieving substantial immunity against eddy currents. Cardiac images are shown, demonstrating excellent image quality and an in-plane resolution of approximately 2.0 mm at >25 frames/s, using one or more receiver coils.

Artifacts↗

Accelerating cine phase-contrast flow measurements using k-t BLAST and k-t SENSE.

Conventional phase-contrast velocity mapping in the ascending aorta was combined with k-t BLAST and k-t SENSE. Up to 5.3-fold net acceleration was achieved, enabling single breath-hold acquisitions. A standard phase-contrast (PC) sequence with interleaved acquisition of the velocity-encoded segments was modified to collect data in 2 stages, a high-resolution under sampled and a low-resolution fully sampled training stage. In addition, a modification of the k-t reconstruction strategy was tested. This strategy, denoted as "plug-in," incorporates data acquired in the training stage into the final reconstruction for improved data consistency, similar to conventional keyhole. "k-t SENSE plug-in" was found to provide best image quality and most accurate flow quantification. For this strategy, at least 10 training profiles are required to yield accurate stroke volumes (relative deviation <5%) and good image quality. In vivo 2D cine velocity mapping was performed in 6 healthy volunteers with 30-32 cardiac phases (spatial resolution 1.3 x 1.3 x 8-10 mm(3), temporal resolution of 18-38 ms), yielding relative stroke volumes of 106 +/- 18% (mean +/- 2*SD) and 112 +/- 15% for 3.8 x and 5.3 x net accelerations, respectively. In summary, k-t BLAST and k-t SENSE are promising approaches that permit significant scan-time reduction in PC velocity mapping, thus making high-resolution breath-held flow quantification possible.

Algorithms↗

Accelerated dynamic Fourier velocity encoding by exploiting velocity-spatio-temporal correlations.

OBJECTIVE: To describe how the information content in a Fourier velocity encoding (FVE) scan can be transformed into a very sparse representation and to develop a method that exploits the compactness of the data to significantly accelerate the acquisition. MATERIALS AND METHODS: For validation, fully sampled FVE datasets were acquired in phantom and in vivo experiments. Fivefold and eightfold acceleration was simulated by using only one fifth or one eighth of the data for reconstruction in the proposed method based on the k-t BLAST framework. Reconstructed images were compared quantitatively to those from the fully sampled data. RESULTS: Velocity spectra in the accelerated datasets were comparable to the spectra from fully sampled datasets. The detected peak velocities remained accurate even at eightfold acceleration, and the overall shape of the spectra was well preserved. Slight temporal smoothing was seen in the accelerated datasets. CONCLUSION: A novel technique for accelerating time-resolved FVE scan is presented. It is possible to accelerate FVE to acquisition speeds comparable to a standard time-resolved phase-contrast scan.

Algorithms↗

Sensitivity-encoded coronary MRA at 3T.

Long scan times are still a main limitation in free-breathing navigator-gated 3D coronary MR angiography (MRA). Unlike other MRI applications, high-resolution coronary MRA has not been amenable to acceleration by parallel imaging techniques due to signal-to-noise ratio (SNR) concerns. In the present work, mitigating SNR limitations by the transition to higher static magnetic field strength is proposed, thus enabling scan time reduction by the parallel sensitivity encoding (SENSE) technique. The study reports the implementation and evaluation of free-breathing navigator-gated 3D coronary MRA with SENSE at 3T. Results from 11 healthy subjects indicate that the approach permits significant scan time reduction in MRA of the left and right coronary systems. Quantitative image analysis and visual grading suggest that two-fold scan acceleration can be accomplished at nearly preserved image quality. The additional experiments appear to demonstrate that parallel MRA equally permits enhancing volume coverage and spatial resolution while maintaining scan time.

Adult↗

Electrodynamics and ultimate SNR in parallel MR imaging.

The purpose of this article is to elucidate inherent limitations to the performance of parallel MRI. The study focuses on the ultimate signal-to-noise ratio (SNR), which refers to the maximum SNR permitted by the electrodynamics of the signal detection process. Using a spherical model object, it is shown that the behavior of the ultimate SNR imposes distinct limits on the acceleration rate in parallel imaging. For low and moderate acceleration, the ultimate SNR performance is nearly optimal, with geometry factors close to 1. However, for high reduction factors beyond a critical value, the ultimate performance deteriorates rapidly, corresponding to exponential growth of the geometry factor. The transition from optimal to deteriorating performance depends on the electrodynamic characteristics of the detected RF fields. In the near-field regime, i.e., for low B0 and small object size, the critical reduction factor is constant and approximately equal to four for 1D acceleration in the sphere. In the far-field wave regime the critical reduction factor is larger and increases both with B0 and object size. Therefore, it is concluded that parallel techniques hold particular promise for human MR imaging at very high field.

Electromagnetic Fields↗

Calibration of echo-planar 2D-selective RF excitation pulses.

Echo-planar radiofrequency (RF) pulses (EPP) are increasingly being used for 2D-selective excitation in MRI. Pulse schemes of this kind are susceptible to eddy-current effects, timing imperfections, and anisotropy of the gradient system. As a consequence, practical EPP implementations have been restricted to robust fly-back strategies that use only every other leg of the echo-planar trajectory for RF transmission. The present work is dedicated to enabling forward-backward EPP with RF transmission during each k-space segment, hence doubling the pulses' time efficiency. This is accomplished by comprehensive pulse calibration based on preparatory measurements of the system imperfections, including potential gradient anisotropy. The effectiveness of the method is demonstrated in vitro and in vivo. By doubling the speed of k-space coverage, the proposed method enhances the potential of EPP for numerous applications. For example, motion-sensitive techniques benefit from shorter feasible echo times (TEs) and improved excitation profiles resulting from reduced in-pulse motion. In sequences with fast repetition, shorter EPP help reduce the overall scan duration. Alternatively, the higher time efficiency of forward-backward EPP can enhance their spatial selectivity.

Anisotropy↗

On the influence of training data quality in k-t BLAST reconstruction.

This work investigated how the quality of prior information (i.e., data acquired during the training stage) influences k-t BLAST reconstruction. The impact of several factors, such as the amount of training data, the presence of spatial misregistration in the training data, and the effects of filtering, was investigated with simulations and in vivo data. It is shown that k-t BLAST outperforms sliding window reconstruction, even with very limited training data. By increasing the amount of training data, reconstruction error continues to decrease, albeit by a diminishing amount. However, an increased amount of training data also increases susceptibility to misregistration of the training data. Filtering of the training data with the goal of reducing truncation artifacts had only minor impact on reconstruction errors. Considering the balance among obtaining the most benefit from the training data, minimizing susceptibility to misregistration, and keeping data acquisition to a minimum, it is concluded that in cardiac imaging the training datasets should be limited to 10-20 profiles in k-space for a typical field of view. The training data may be acquired in a separate breathhold without much penalty, if care is taken to minimize misregistration, such as with a navigator.

Adult↗

Parallel imaging performance as a function of field strength--an experimental investigation using electrodynamic scaling.

In this work, the dependence of parallel MRI performance on main magnetic field strength is experimentally investigated. Using the general framework of electrodynamic scaling, the B0-dependent behavior of the relevant radiofrequency fields at a single physical field strength of 7 T is studied. In the chosen implementation this is accomplished by adjusting the permittivity and conductivity of a homogeneous spherical phantom. With different mixing ratios of decane, ethanol, purified water, N-methylformamide, and sodium chloride, field strengths in the range of 1.5 to 11.5 T are mimicked. Based on sensitivity maps of an eight-coil receiver array, the field-dependent performance of parallel imaging is assessed in terms of the geometry factor g, which reflects noise enhancement in parallel imaging reconstruction. At low field strengths the SNR penalty was nearly independent of B0 and favorably low for 1D reduction factors up to between 3 and 4. At higher field strengths the transition between favorable and prohibitive parallel imaging conditions was found to shift toward higher feasible reduction factors. These findings are in good agreement with previous theoretical predictions. From this agreement it is concluded that parallel MRI at high B0 benefits specifically from onsetting far-field behavior of the involved radiofrequency fields.

Electromagnetic Fields↗

Equi-ripple design of quadratic-phase RF pulses.

An improved strategy for the design of quadratic-phase RF pulses with high selectivity and broad bandwidths using the Shinnar-Le Roux (SLR) transformation is proposed. Unlike previous implementations, the required quadratic-phase finite impulse response (FIR) filters are generated using the complex Remez exchange algorithm, which ensures an equi-ripple deviation from the ideal response function. It is argued analytically that quadratic-phase pulses are near-optimal in terms of minimising the B1-amplitude for a given bandwidth and flip angle. Furthermore, several parameter relations are derived, providing practical design guidelines. The effectiveness of the proposed design method is demonstrated by examples of excitation and saturation pulses applied in vitro and in vivo.

Algorithms↗

Parallel imaging at high field strength: synergies and joint potential.

MRI faces fundamental limitations in terms of sensitivity and speed. These limitations can be effectively tackled by the transition to higher field strengths and parallel imaging technology. Owing to largely independent physics, the two approaches can be readily combined. Considering the specific advantages and disadvantages of high field strength and parallel imaging, it is found that the combination is particularly synergistic. In the joint approach, the two concepts play different roles. Higher field strength acts as a source of higher baseline signal-to-noise ratio (SNR), while parallelization acts as a means of converting added SNR into a variety of alternative benefits. This interplay holds promise for a broad range of clinical applications, as recently illustrated by several imaging studies at 3 T. As a consequence, clinical MRI at 3 T and higher is expected to rely more on parallel acquisition than at lower field strength. The specific synergy with parallel imaging may even make 3 T the field strength of choice for a range of exams that conventionally work best at 1.5 T or less.

Diffusion Magnetic Resonance Imaging↗

Parallel spectroscopic imaging with spin-echo trains.

A reduction in scan time in spectroscopic imaging (SI) can be achieved by both fast and reduced k-space sampling. This work presents an ultrafast SI technique that combines the two approaches. The synergy of multiple spin-echo (MSE) acquisition and sensitivity encoding (SENSE) enables high-resolution SI to be performed within a clinically acceptable scan time. MSE-SENSE-SI with echo train lengths ranging from one to four echoes is evaluated with respect to SNR and spatial response function by means of in vitro experiments. It is shown that acquiring two spin-echoes (SEs) per acquisition yields a good practical trade-off among scan time, SNR, and spatial response. The clinical feasibility of the technique is demonstrated in a patient with an astrocytoma, and SI data are obtained with an image matrix of 24 x 24 in just over 2 min.

Astrocytoma↗

k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations.

Dynamic images of natural objects exhibit significant correlations in k-space and time. Thus, it is feasible to acquire only a reduced amount of data and recover the missing portion afterwards. This leads to an improved temporal resolution, or an improved spatial resolution for a given amount of acquisition. Based on this approach, two methods were developed to significantly improve the performance of dynamic imaging, named k-t BLAST (Broad-use Linear Acquisition Speed-up Technique) and k-t SENSE (SENSitivity Encoding) for use with a single or multiple receiver coils, respectively. Signal correlations were learned from a small set of training data and the missing data were recovered using all available information in a consistent and integral manner. The general theory of k-t BLAST and k-t SENSE is applicable to arbitrary k-space trajectories, time-varying coil sensitivities, and under- and overdetermined reconstruction problems. Examples from ungated cardiac imaging demonstrate a 4-fold acceleration (voxel size 2.42 x 2.52 mm(2), 38.4 fps) with either one or six receiver coils. k-t BLAST and k-t SENSE are applicable to many areas, especially those exhibiting quasiperiodic motion, such as imaging of the heart, the lungs, the abdomen, and the brain under periodic stimulation.

Heart↗