PubMed Health⌕ Search

Biomedical subjects

Klaes Golman

Publications and source records attributed to Klaes Golman.

At least 19 recordsLinked to original sources

Metabolic imaging by hyperpolarized 13C magnetic resonance imaging for in vivo tumor diagnosis.

The "Warburg effect," an elevation in aerobic glycolysis, may be a fundamental property of cancer cells. For cancer diagnosis and treatment, it would be valuable if elevated glycolytic metabolism could be quantified in an image in animals and humans. The pyruvate molecule is at the metabolic crossroad for energy delivery inside the cell, and with a noninvasive measurement of the relative transformation of pyruvate into lactate and alanine within a biologically relevant time frame (seconds), it may be possible to quantify the glycolytic status of the cells. We have examined the metabolism after i.v. injection of hyperpolarized (13)C-pyruvate in rats with implanted P22 tumors. The strongly enhanced nuclear magnetic resonance signal generated by the hyperpolarization techniques allows mapping of pyruvate, lactate, and alanine in a 5 x 5 x 10 mm(3) imaging voxel using a 1.5 T magnetic resonance scanner. The magnetic resonance scanning (chemical shift imaging) was initiated 24 seconds after the pyruvate injection and had a duration of 14 seconds. All implanted tumors showed significantly higher lactate content than the normal tissue. The results indicate that noninvasive quantification of localized Warburg effect may be possible.

Alanine↗

Gadolinium contrast media are more nephrotoxic than iodine media. The importance of osmolality in direct renal artery injections.

A study was undertaken of the role of osmotoxicity in gadolinium (Gd) and iodine contrast media (CM) nephrotoxicity in ischemic porcine kidneys. Test solutions: mannitol iso-osmotic to 0.5 M: gadopentetate (1.96 Osm/kg H2O), 0.5 M: gadodiamide (0.78 Osm/kg H2O) and 0.5 M: iohexol (190 mg I/ml, 0.42 Osm/kg H2O). Each solution was injected [3 ml/kg body weight (BW)] into the balloon-occluded (10 min) renal artery of eight left-sided nephrectomized pigs. The plasma half-life of a glomerular filtration rate (GFR) marker was used to compare their effects on GFR 1-3 h post-injection. The median half-lives of the GFR marker after injection of gadopentetate (1,730 min) and mannitol 1.96 Osm/kg H2O (2,782 min) did not differ statistically (P = 0.28), but were significantly longer than after all other solutions (P < 0.001). There was no significant difference (P = 0.06) between gadodiamide (218 min) and mannitol 0.82 Osm/kg H2O (169 min), while there was (P = 0.03) between iohexol (181 min) and mannitol 0.43 Osm/kg H2O (148 min). The difference between gadodiamide and iohexol was significant (P = 0.01). Reduction in GFR, as a marker of nephrotoxicity, induced by gadopentetate correlated with its high osmolality, while the effect of gadodiamide and iohexol may include chemotoxicity. Iohexol molecules were less nephrotoxic than the Gd-CM molecules and contain three-times the number of attenuating atoms per molecule.

Animals↗

Real-time metabolic imaging.

The endogenous substance pyruvate is of major importance to maintain energy homeostasis in the cells and provides a window to several important metabolic processes essential to cell survival. Cell viability is therefore reflected in the metabolism of pyruvate. NMR spectroscopy has until now been the only noninvasive method to gain insight into the fate of pyruvate in the body, but the low NMR sensitivity even at high field strength has only allowed information about steady-state conditions. The medically relevant information about the distribution, localization, and metabolic rate of the substance during the first minute after the injection has not been obtainable. Use of a hyperpolarization technique has enabled 10-15% polarization of (13)C(1) in up to a 0.3 M pyruvate solution. i.v. injection of the solution into rats and pigs allows imaging of the distribution of pyruvate and mapping of its major metabolites lactate and alanine within a time frame of approximately 10 s. Real-time molecular imaging with MRI has become a reality.

Animals↗

MR coronary angiography in pigs with intraarterial injections of a hyperpolarized 13C substance.

A new diagnostic application of a water-soluble contrast medium (CM) based on the hyperpolarization of a 13C substance is introduced. The degree of polarization achieved is >30%, which is about a factor of 10(5) higher than the thermal equilibrium polarization level at 1.5 T. Imaging of hyperpolarized (HP) CM during a cardiac interventional MRI procedure was studied. Catheters were positioned in the left and right coronary arteries of pigs. A coil tuned to 13C was used for nonproton imaging. The HP-13C CM ( approximately 5 ml, 0.5 M, approximately 30% polarization) was injected during projection imaging using a fully balanced steady-state free precession (SSFP) pulse sequence with and without cardiac gating. The contrast agent-filled catheter was clearly visible during the procedure. The coronary arteries were well depicted and the signal-to-noise ratios (SNRs) were in the range of 10-40. The use of HP-13C CM may provide a new diagnostic procedure for interventional MRI.

Animals↗

13C imaging-a new diagnostic platform.

The evolution of magnetic resonance imaging (MRI) has been astounding since the early 1980s, and a broad range of applications has emerged. To date, clinical imaging of nuclei other than protons has been precluded for reasons of sensitivity. However, with the recent development of hyperpolarization techniques, the signal from a given number of nuclei can be increased as much as 100,000 times, sufficient to enable imaging of nonproton nuclei. Technically, imaging of hyperpolarized nuclei offers several unique properties, such as complete lack of background signal and possibility for local and permanent destruction of the signal by means of radio frequency (RF) pulses. These properties allow for improved as well as new techniques within several application areas. Diagnostically, the injected compounds can visualize information about flow, perfusion, excretory function, and metabolic status. In this review article, we explain the concept of hyperpolarization and the techniques to hyperpolarize 13C. An overview of results obtained within angiography, perfusion, and catheter tracking is given, together with a discussion of the particular advantages and limitations. Finally, possible future directions of hyperpolarized 13C MRI are pointed out.

Angiography↗

3He MRI-based assessment of posture-dependent regional ventilation gradients in rats.

A recently developed method for quantitative assessment of regional lung ventilation was employed for the study of posture-dependent ventilation differences in rats. The measurement employed hyperpolarized (3)He MRI to detect the build-up of the signal intensity after increasing numbers of (3)He breaths, which allowed for computation of a regional ventilation parameter. A group of six anesthetized rats was studied in both supine and prone postures. Three-dimensional maps of the ventilation parameter were obtained with high spatial resolution (voxel volume approximately 2 mm(3)). Vertical (dorsal-ventral) gradients of the ventilation index, defined as the regional ventilation normalized by the average ventilation within the whole lung, were investigated. Variations in the regional distribution of the ventilation parameter, as well as of the ventilation index, could be detected, depending on the posture of the rats. In supine posture, ventilation was elevated in the dependent parts of the lungs, with a linear gradient of the ventilation index of -0.11 +/- 0.03 cm(-1). In prone posture, the distribution of ventilation was more uniform, with a significantly (P < 0.001) smaller gradient of the ventilation index of -0.01 +/- 0.02 cm(-1). It is concluded that the (3)He MRI-based method can detect and quantify regional ventilation gradients in animals as small as the rat and that these gradients depend on prone or supine posture of the animal.

Administration, Inhalation↗

Increase in signal-to-noise ratio of > 10,000 times in liquid-state NMR.

A method for obtaining strongly polarized nuclear spins in solution has been developed. The method uses low temperature, high magnetic field, and dynamic nuclear polarization (DNP) to strongly polarize nuclear spins in the solid state. The solid sample is subsequently dissolved rapidly in a suitable solvent to create a solution of molecules with hyperpolarized nuclear spins. The polarization is performed in a DNP polarizer, consisting of a super-conducting magnet (3.35 T) and a liquid-helium cooled sample space. The sample is irradiated with microwaves at approximately 94 GHz. Subsequent to polarization, the sample is dissolved by an injection system inside the DNP magnet. The dissolution process effectively preserves the nuclear polarization. The resulting hyperpolarized liquid sample can be transferred to a high-resolution NMR spectrometer, where an enhanced NMR signal can be acquired, or it may be used as an agent for in vivo imaging or spectroscopy. In this article we describe the use of the method on aqueous solutions of [13C]urea. Polarizations of 37% for 13C and 7.8% for 15N, respectively, were obtained after the dissolution. These polarizations correspond to an enhancement of 44,400 for 13C and 23,500 for 15N, respectively, compared with thermal equilibrium at 9.4 T and room temperature. The method can be used generally for signal enhancement and reduction of measurement time in liquid-state NMR and opens up for a variety of in vitro and in vivo applications of DNP-enhanced NMR.

Magnetic Resonance Spectroscopy↗

Molecular imaging with endogenous substances.

Dynamic nuclear polarization has enabled hyperpolarization of nuclei such as 13C and 15N in endogenous substances. The resulting high nuclear polarization makes it possible to perform subsecond 13C MRI. By using the dynamic nuclear polarization hyperpolarization technique, 10% polarization was obtained in an aqueous solution of 100 mM 13C-labeled urea, ready for injection. The in vivo T1 relaxation time of 13C in the urea solution was determined to 20 +/- 2 s. Due to the long relaxation time, it is possible to use the hyperpolarized substance for medical imaging. A series of high-resolution ( approximately 1-mm) magnetic resonance images were acquired, each with a scan time of 240 ms, 0-5 s after an i.v. injection of the hyperpolarized aqueous [13C]urea solution in a rat. The results show that it is possible to perform 13C angiography with a signal-to-noise ratio of approximately 275 in approximately 0.25 s. Perfusion studies with endogenous substances may allow higher spatial and/or temporal resolution than is possible with current proton imaging techniques.

Animals↗

Characterization of diffusing capacity and perfusion of the rat lung in a lipopolysaccaride disease model using hyperpolarized 129Xe.

The ability to quantify pulmonary diffusing capacity and perfusion using dynamic hyperpolarized (129)Xe NMR spectroscopy is demonstrated. A model of alveolar gas exchange was developed, which, in conjunction with (129)Xe NMR, enables quantification of average alveolar wall thickness, pulmonary perfusion, capillary diffusion length, and mean transit time. The technique was employed to compare a group of naïve rats (n = 10) with a group of rats with acute inflammatory lung injury (n = 10), caused by instillation of lipopolysaccaride (LPS). The measured structural and perfusion-related parameters were in agreement with reported values from studies using non-NMR methods. Significant differences between the groups were found in total diffusion length (control 8.5 +/- 0.5 microm, LPS 9.9 +/- 0.6 microm, P < 0.001), in capillary diffusion length (control 2.9 +/- 0.4 microm, LPS 3.9 +/- 1.0 microm, P < 0.05), and in pulmonary hematocrit (control 0.55 +/- 0.06, LPS 0.43 +/- 0.08, P < 0.01), whereas no differences were observed in alveolar wall thickness, pulmonary perfusion, and mean transit time. These results demonstrate the ability of the method to distinguish two main aspects of lung function, namely, diffusing capacity and pulmonary perfusion.

Animals↗

Overhauser enhanced magnetic resonance imaging for tumor oximetry: coregistration of tumor anatomy and tissue oxygen concentration.

An efficient noninvasive method for in vivo imaging of tumor oxygenation by using a low-field magnetic resonance scanner and a paramagnetic contrast agent is described. The methodology is based on Overhauser enhanced magnetic resonance imaging (OMRI), a functional imaging technique. OMRI experiments were performed on tumor-bearing mice (squamous cell carcinoma) by i.v. administration of the contrast agent Oxo63 (a highly derivatized triarylmethyl radical) at nontoxic doses in the range of 2-7 mmol/kg either as a bolus or as a continuous infusion. Spatially resolved pO(2) (oxygen concentration) images from OMRI experiments of tumor-bearing mice exhibited heterogeneous oxygenation profiles and revealed regions of hypoxia in tumors (<10 mmHg; 1 mmHg = 133 Pa). Oxygenation of tumors was enhanced on carbogen (95% O(2)/5% CO(2)) inhalation. The pO(2) measurements from OMRI were found to be in agreement with those obtained by independent polarographic measurements using a pO(2) Eppendorf electrode. This work illustrates that anatomically coregistered pO(2) maps of tumors can be readily obtained by combining the good anatomical resolution of water proton-based MRI, and the superior pO(2) sensitivity of EPR. OMRI affords the opportunity to perform noninvasive and repeated pO(2) measurements of the same animal with useful spatial (approximately 1 mm) and temporal (2 min) resolution, making this method a powerful imaging modality for small animal research to understand tumor physiology and potentially for human applications.

Algorithms↗

Quantitative measurement of regional lung ventilation using 3He MRI.

A new strategy for a quantitative measurement of regional pulmonary ventilation using hyperpolarized helium-3 (3He) MRI has been developed. The method employs the build-up of the signal intensity after a variable number of (3)He breaths. A mathematical model of the signal dynamics is presented, from which the local ventilation, defined as the fraction of gas exchanged per breath within a given volume, is calculated. The model was used to create ventilation maps of coronal slices of guinea pig lungs. Ventilation values very close to 1 were found in the trachea and the major airways. In the lung parenchyma, regions adjacent to the hilum showed values of 0.6-0.8, whereas 0.2-0.4 was measured in peripheral regions. Monte Carlo simulations were used to investigate the accuracy of the method and its limitations. The simulations revealed that, at presently attainable signal-to-noise ratios, the ventilation parameter can be determined with a relative uncertainty of <5% over a wide range of values.

Animals↗

A study of the use of Overhauser enhancement to assist with needle and catheter placement during interventional MRI.

The practicability of using Overhauser enhancement of saline in interventional MRI was investigated. Saline was used as a means of marking the path taken by a fluid-filled cavity, similar to that formed by a needle, catheter, or cannula during interventional MRI procedures. A prototype device was designed and constructed for saturation and propulsion of 0.6 ml of doped liquid. The pertinent Overhauser parameters, such as the obtainable enhancement factor, were measured. Signal enhancement in excess of 10 was demonstrated in practice by acquiring images showing an enhancement of fluid in a catheter tube.

Animals↗

13C-angiography.

Explore the source record for details and available documents.

Animals↗