PubMed Health⌕ Search

Biomedical subjects

Klara Valko

Publications and source records attributed to Klara Valko.

2 recordsLinked to original sources

Fast gradient HPLC method to determine compounds binding to human serum albumin. Relationships with octanol/water and immobilized artificial membrane lipophilicity.

A fast gradient HPLC method (cycle time 15 min) has been developed to determine Human Serum Albumin (HSA) binding of discovery compounds using chemically bonded protein stationary phases. The HSA binding values were derived from the gradient retention times that were converted to the logarithm of the equilibrium constants (logK HSA) using data from a calibration set of molecules. The method has been validated using literature plasma protein binding data of 68 known drug molecules. The method is fully automated, and has been used for lead optimization in more than 20 company projects. The HSA binding data obtained for more than 4000 compounds were suitable to set up global and project specific quantitative structure binding relationships that helped compound design in early drug discovery. The obtained HSA binding of known drug molecules were compared to the Immobilized Artificial Membrane binding data (CHI IAM) obtained by our previously described HPLC-based method. The solvation equation approach has been used to characterize the normal binding ability of HSA, and this relationship shows that compound lipophilicity is a significant factor. It was found that the selectivity of the "baseline" lipophilicity governing HSA binding, membrane interaction, and octanol/water partition are very similar. However, the effect of the presence of positive or negative charges have very different effects. It was found that negatively charged compounds bind more strongly to HSA than it would be expected from the lipophilicity of the ionized species at pH 7.4. Several compounds showed stronger HSA binding than can be expected from their lipophilicity alone, and comparison between predicted and experimental binding affinity allows the identification of compounds that have good complementarities with any of the known binding sites.

Blood Proteins↗

Lipophilicity and pKa estimates from gradient high-performance liquid chromatography.

The linear-solvent strength (LSS) model of gradient elution has been applied to estimate parameters of lipophilicity and acidity of a series of drugs and model chemicals. Apparent pKa values and log kw values for individual analytes were determined in 2-3 gradient runs. The first experiment (or first two experiments) uses a wide-range organic modifier gradient with pH chosen for suppressed ionization of the analyte. The result of this experiment allows an estimate of contents of organic modifier of the mobile phase (%B) providing the required retention coefficient, k, for the non-ionized analyte. The following experiment is carried out with the latter %B and a pH-gradient of the aqueous component of the eluent that is sufficient to overlap the possible pKa-value of the analyte. The initial pH of the buffer used to make the mobile phase is selected to insure that the analyte is in non-ionized form. The resulting retention time allows an estimate of PKa in a solvent of the selected %B. At the same time, estimates of log kw can also be obtained. The log kw parameter obtained from gradient HPLC by the approach proposed correlated well with the corresponding value obtained by standard procedure of extrapolation of retention data determined in a series of isocratic measurements. Correlation between log kw and the reference parameter of lipophilicity, log P, was very good for a series of test analytes and satisfactory for a structurally diverse series of drugs. The approach supported with specific detection procedures can be recommended for fast screening of lipophilicity of individual components of complex mixtures like those produced by combinatorial chemistry. The values of pKa obtained in a study were found to correlate with the literature pKa data determined in water for a set of aniline derivatives studied. In case of a series of drugs the correlation was less than moderate if the general procedure of pKa determination was applied.

Chromatography, High Pressure Liquid↗