Radiation exposure during cardiac CT: effective doses at multi-detector row CT and electron-beam CT.

PURPOSE: To measure the effective radiation doses delivered at electron-beam computed tomography (CT) and multi-detector row spiral CT of coronary arteries and to compare these doses with those delivered at catheter coronary angiography. MATERIALS AND METHODS: An anthropomorphic phantom equipped with 66 thermoluminescent dosimeters was imaged at cardiac CT. Four protocols for unenhanced coronary artery calcium scoring were simulated: one with electron-beam CT and three with multi-detector row CT. Four similar protocols for coronary CT angiography were simulated. All multi-detector row spiral CT protocols were performed with retrospective electrocardiographic triggering. Biplane catheter coronary angiography also was simulated. Radiation doses to organs were measured, and effective doses were calculated according to guidelines published in International Commission on Radiological Protection Publication 60. RESULTS: Coronary artery calcium scoring with electron-beam CT yielded effective radiation doses of 1.0 and 1.3 mSv for male and female patients, respectively. The radiation doses at calcium scoring with multi-detector row CT were 1.5-5.2 mSv for male patients and 1.8-6.2 mSv for female patients. Electron-beam CT coronary angiography yielded effective doses of 1.5 and 2.0 mSv for male and female patients, respectively. The highest effective doses were delivered at multi-detector row CT angiography: 6.7-10.9 mSv for male patients and 8.1-13.0 mSv for female patients. Catheter coronary angiography yielded effective doses of 2.1 and 2.5 mSv for male and female patients, respectively. CONCLUSION: Higher radiation doses are delivered at multi-detector row cardiac CT compared with the doses delivered at electron-beam CT and catheter coronary angiography.

Coronary Angiography↗

Effective doses in standard protocols for multi-slice CT scanning.

The purpose of this study was to assess the radiation exposure of patients in several standard protocols in multi-slice CT (MSCT). Scanning protocols for neck, chest, abdomen, and spine were examined on a Somatom Plus 4 Volume Zoom MSCT (Siemens, Erlangen, Germany) with changing slice collimation (4x1, 4x2.5, and 4x5 mm), and pitch factors (1, 1.5, and 2). Effective doses were calculated from LiF-TLD measurements at several organ sites using an Alderson-Rando phantom and compared with calculations using the weighted CTDI. Effective dose for MSCT of the neck was 2.8 mSv. For different protocols for MSCT of the chest, 7.5-12.9 mSv were found. In abdominal MSCT protocols, effective dose varied between 12.4 and 16.1 mSv. The MSCT of the spine may lead to 12 mSv. An excellent correlation between the effective dose as determined by LiF-TLD and the calculated effective dose using the weighted CTDI could be demonstrated; however, a difference of up to 30% (mean 14.3%) was noted. Standard protocols for MSCT as measured in this study showed effective doses of up to16 mSv. Phantom measurement data show a good correlation to estimations using the weighted CTDI.

Abdomen↗