Accuracy of single-session extracranial radiotherapy for simple shaped lung tumor or metastasis using fast 3-D CT treatment planning.

BACKGROUND: This study is situated in the area of measuring set-up accuracy and time periods of single-session extracranial radiotherapy (SSRT) for simple-shaped targets (e.g., spherical or rotational symmetrical) definitively located in the peripheral lung. METHODS AND MATERIALS: After adaptation of the stereotactic body frame, the patient has to remain in the vacuum pillow during planning computed tomography (CT), fast three-dimensional (3-D) treatment planning, and direct irradiation after verification. Fast preplanning is performed by using virtual simulation software to accelerate the method. RESULTS: In our new procedure, SSRT is applied in approximately 1.5 h. The mean setup accuracy vector was 2.4+/-0.7 mm in the range of 1.34 to 4 mm. Mean intrafractional patient movement in the stereotactic body frame before and after radiation was 0.70 mm+/-0.5 mm and 0.76+/-0.76 mm in the range of 0 to 2.8 mm. Mean time period steps were measured at (1) planning CT with 3-D treatment planning: 76+/-12 min; (2) irradiation and verification: 33+/-7 min; and (3) complete procedure duration: 109+/-11 min (range, 89-169). CONCLUSIONS: The main difference between the positioning technique of SSRT and that of conventional extracranial radiosurgery is the tighter patient fixation, which guarantees minimal patient movement. The main advantages are procedure acceleration and omission of CT simulation. SSRT is a preliminary stage of real-time treatment.

Aged↗

Evaluation of a laser system for CT software simulation (EXOMIO) in patients with breast cancer.

PURPOSE: To develop a manually movable laser system connected to the CT table for alignment of the isocenter cross of irradiation fields on the patient's skin directly after CT software simulation. MATERIAL AND METHODS: The specially designed laser system was constructed in the authors' department, and the mean focusing accuracy of isocenter translations was analyzed using Alderson phantom measurements. The mean overall accuracy from setup to treatment of the whole procedure of CT software simulation was measured by the comparison of bone structures and mamma contour of the digitally reconstructed radiograph (DRR) with the verification film. The time taken for the different setup procedure steps was evaluated for 70 breast cancer patients who were treated using tangential fields. RESULTS: The mean focusing accuracy of the manually movable laser system after defined isocenter translation was measured as 0.8 +/- 0.5 mm, the mean patient movement on the CT table as 2.0 +/- 1 mm, and the mean positioning accuracy of the first treatment after patient positioning corresponding to the skin alignments as 3.9 +/- 1.5 mm. The time periods for the different steps of the CT software simulation were measured, and the total duration was found to be 35.8 +/- 3.3 min. CONCLUSION: In general, the main advantage of well-known CT software simulation when compared to conventional simulation is the relief of the real X-ray simulator which is feasible with fast planning software (EXOMIO) and the presented movable laser system.

Adult↗

Effects of altering infusion parameters on intimal hyperplasia following local catheter-based delivery into the rabbit iliac artery.

BACKGROUND: Efficient local gene or drug therapy requires optimized application modalities to avoid vessel damage, which might lead to increased neointimal hyperplasia. Aim of the study was to evaluate different application parameters for local delivery using the channeled balloon catheter in order to minimize vessel trauma induced by local application. METHODS AND RESULTS: Sixty cholesterol fed rabbits were randomly enrolled into twelve groups of different local application parameters: group I, application pressure 2atm/application volume 1ml physiologic saline; group II, 2atm/2ml; group III, 2atm/5ml; group IV, 4atm/1ml; group V, 4atm/2ml; group VI, 4atm/5ml. The other six groups received Ringer's solution instead of saline. Administration of the solution was randomly performed in one iliac artery using the channeled balloon catheter with simultaneous balloon angioplasty (8atm). The contralateral iliac artery served as a control and was treated with balloon angioplasty only. Four weeks after local therapy, calibrated angiography was performed; the animals were sacrificed, vessel segments were excised and quantitative morphometric measurements were obtained. In none of the animals acute complications, e.g. dissection, thrombosis or perforation of the vessel, was noted. Up to an application pressure of 4atm and an application volume of 5ml, no significant neointima formation was seen compared to arteries which underwent angioplasty only. Additionally, no significant differences between saline and Ringer's solution were detected. In a multivariate analysis, neither application pressure nor volume were found to have a statistically significant influence on the amount of neointimal hyperplasia. CONCLUSIONS: Local application of "drugs" using the channeled balloon catheter is safe and feasible without significant induction of neointimal hyperplasia compared to angioplasty, if an application volume of 5ml and a pressure of 4atm is not exceeded.

Angiography↗

In vitro MR imaging of regulated gene expression.

PURPOSE: To design and evaluate a construct that allows regulated expression of the magnetic resonance (MR) imaging reporter gene human tyrosinase under control of the tetracycline response element. MATERIALS AND METHODS: A breast cancer cell line (MCF-7) was transfected with a plasmid that codes for the tetracycline-controlled transactivator and a new construct. In this construct, the reporter gene human tyrosinase is under control of the tetracycline response element, thus allowing suppression of gene expression by adding doxycycline (tetracycline switched off). A reverse transcription polymerase chain reaction was conducted to evaluate gene expression. Additionally, immunohistochemical investigation of tyrosinase and melanin staining was undertaken to analyze the presence of these molecules. After culture in an iron- and holotransferrin-enriched medium, cells were imaged in a 1.0-T clinical MR imager by using a surface coil and T1-weighted spin-echo and gradient-echo sequences. RESULTS: Two stable transfected cell clones were established. Cells cultured with doxycycline showed no background expression of the human tyrosinase gene, whereas withdrawal of doxycycline resulted in detectable tyrosinase messenger RNA expression. Gene expression results in a detectable tyrosinase protein level and melanin content. Increased signal intensity on T1-weighted MR images in cells that expressed the reporter gene was observed in comparison to genetically identical cells with the reporter gene switched off. CONCLUSION: Our construct enables MR imaging of regulated tyrosinase gene expression in vitro.

Breast Neoplasms↗

Magnetic resonance urography in pediatric urology.

OBJECTIVE: To evaluate the efficiency of magnetic resonance urography (MRU) in pediatric urology. MATERIAL AND METHODS: We report retrospectively on 12 children who underwent MRU between January 1999 and November 2001. MRU was performed to accurately evaluate the entire urinary tract because of megaureter, ectopic ureter, vesicoureteral reflux, Y-inverted duplication and hydronephrosis because of pyeloureteral stenosis. T1- and T2-weighted images were obtained in the coronal, sagittal and axial planes. The mean age of the children (8 females, 4 males) investigated was 36 months (range 2-140 months). RESULTS: An accurate anatomical picture of the entire urinary tract could be obtained in all children. The obstructive nature of megaureter could be differentiated. The distal orifice of ectopic ureter could be identified in the vagina. Vesicoureteral reflux into the blind-ending ureteral bud of a duplicated system was accurately identified. Hydronephrosis was demonstrated to be the result of pyeloureteral stenosis. The location of stenoses was easily identified in the sagittal and coronal planes. CONCLUSIONS: MRU is an excellent imaging modality for accurately depicting the urinary tract. MRU is superior to conventional intravenous urography because it does not use ionizing radiation, the gadolinium contrast medium used is not nephrotoxic and the imaging quality is excellent, reproducible and not interfered with by gas superposition. Considering the high costs and diagnostic benefit of MRU compared to intravenous urography, MRU should be performed in patients with impaired renal function, in those with an allergy to contrast medium and if anatomic relationships are not clear prior to reconstructive surgery.

Age Factors↗

1-molar gadobutrol as a contrast agent for computed tomography: results from a comparative porcine study.

RATIONALE AND OBJECTIVES: To evaluate prospectively the efficacy of gadobutrol as contrast agent for computed tomography (CT) compared with iodinated contrast media in a porcine animal model. METHODS: In 8 domestic pigs (35 +/- 4 kg body weight [BW]), continuous spiral CTs of the chest and abdomen were performed using either 2 mmol/kg BW Gadovist 1.0 (1 mol/L gadobutrol) intravenously or Ultravist (300 mg I/mL iopromide) (slice 5 mm, table feed 7.5 mm, reconstruction increment 5 mm). One week later, the same animals were examined using the same protocol with the other contrast agent. In 2 additional animals, serial CTs were performed at the same level using gadobutrol or iopromide on day 1 and the alternate agent on day 8 inches order to determine contrast media kinetics, peak enhancement, and time enhancement-product in important vascular regions and parenchymal organs (abdominal aorta, inferior vena cava, liver, and renal parenchyma). Peak enhancement (net increase compared with nonenhanced baseline values) was measured in Hounsfield units (HU) in defined regions of interest. RESULTS: In vivo, the mean peak enhancement 5, 15, 30, and 120 seconds in the abdominal aorta after injection of 2 mL/kg BW gadobutrol and iopromide was 200 +/- 11, 224 +/- 10, 261 +/- 13, and 95 +/- 9 HU versus 232 +/- 10, 298 +/- 10, 152 +/- 11, and 123 +/- 10 HU, respectively. Differences in enhancement of vascular structures was statistically significant (P < 0.05) in carotid arteries (235 +/- 20 HU for gadobutrol and 264 +/- 19 HU for iopromide) and the aortic arch (261 +/- 14 HU for gadobutrol and 279 HU +/- 13 HU for iopromide). No statistical significance was seen in all other measured vascular structures and parenchymal organs. CONCLUSION: Contrast-enhanced CT with 1 mol/L gadobutrol in a dose of 2 mmol/kg BW resulted in an excellent vascular and parenchymal enhancement in most vascular regions and parenchymal organs similar to an equivalent volume of 300 mg/mL iodinated contrast media.

Animals↗

Superselective embolization with coils in high-flow priapism.

Priapism can be divided into "low-flow" veno-occlusive priapism and, especially in children, rare "high-flow" arterial priapism. We report a 5-year-old boy who developed arterial priapism after blunt perineal trauma that was successfully treated by superselective embolization with microcoils.

Angiography↗

X-ray digital subtraction angiography with 1 mol/L gadobutrol: results from a comparative porcine study With iodinated contrast agents.

RATIONALE AND OBJECTIVES: To evaluate prospectively diagnostic accuracy of 1 mol/L gadobutrol as a contrast agent for intraarterial x-ray digital subtraction angiography (DSA) in comparison to iodinated, nonionic contrast media and 0.5 mol/L gadolinium-DTPA. METHODS: Flush arteriograms (ascending, descending, abdominal aorta, iliac, and femoral arteries) and selective angiograms (carotid, renal, and visceral arteries) were obtained from bilateral femoral arterial access (5 F sheaths) in 10 domestic pigs (70 kg body weight). Digital subtracted angiograms were obtained during injection of undiluted 1 mol/L gadobutrol, 300 mg I/mL iopromide, or 0.5 mol/L gadopentetate. Injection parameters (volume and velocity) were similar for all three contrast agents. In paired arteries, two different contrast media were used during the same angiographic run. Diagnostic quality and accuracy of the angiograms were evaluated on a three-step scale by three independent blinded investigators. RESULTS: Sufficient nonselective angiographic images were obtained in 90% of cases using iodinated contrast material. Gadobutrol achieved sufficient nonselective angiograms in 64%. Selective angiograms were sufficient in 98% using iodinated contrast material, 90% using 1 mol/L Gadobutrol and 48% using 0.5 mol/L Gd-DTPA. Adverse reactions to any of the used contrast agents were not noted. CONCLUSION: One mol/L Gadobutrol solution allows x-ray digital subtraction angiography with a diagnostic accuracy equivalent to 300 mg/mL iodinated contrast media, if selective injections are performed. Flush aortograms are of inferior image quality to iodinated contrast material.

Angiography, Digital Subtraction↗

Comparative study of MR sialography and digital subtraction sialography for benign salivary gland disorders.

BACKGROUND AND PURPOSE: MR sialography has become an alternative imaging technique for ductal salivary gland diseases. We compared the diagnostic accuracies of MR sialography and digital subtraction sialography in patients with successful completion of both examinations and benign salivary gland disorders. METHODS: In a prospective study, we attempted to examine salivary glands in 80 patients with clinically suspected diagnoses of sialadenitis and/or sialolithiasis. Each patient underwent digital subtraction sialography and MR sialography. MR sialography was obtained with a T2-weighted single-shot turbo spin-echo sequence (TR/TE 2800/1100 msec, acquisition time 7 seconds), with use of a quadrature head coil. Final diagnoses were confirmed by clinical follow-up and results of biopsy (n = 9) or surgery (n = 19). RESULTS: Failure rate was 5% (four of 80) for MR sialography and 14% (11 of 80) for digital subtraction sialography. Eighty-one salivary glands (48 parotid, 33 submandibular) in 65 patients were successfully visualized with both modalities. MR sialography depicted the main ductal system and first- and second-order branches, whereas digital subtraction sialography was able to depict third-order branches. Sensitivity and specificity to diagnose chronic sialadenitis were 70% and 98% with MR and 96% and 100% with digital subtraction sialography. MR sialography enabled diagnosis of sialolithiasis with a sensitivity of 80% and a specificity of 98% versus 90% and 98% for each with digital subtraction sialography. CONCLUSION: MR sialography with a heavily T2-weighted sequence is highly successful in the noninvasive visualization of the ductal system of major salivary glands. It is useful for diagnosing sialolithiasis and sialadenitis. Digital subtraction sialography, an invasive technique, had a substantial procedural failure rate, particularly for the submandibular duct. However, because of its higher spatial resolution, successfully completed digital subtraction sialography achieved superior diagnostic information compared with that of MR sialography.

Adolescent↗

Local administration of NF-kappa B decoy oligonucleotides to prevent restenosis after balloon angioplasty: an experimental study in New Zealand white rabbits.

PURPOSE: To evaluate the efficacy of NF-kappa B oligonucleotides (ODN) administered by local administration with the channeled balloon catheter to prevent restenosis after balloon angioplasty in restenotic iliac arteries of New Zealand white rabbits. MATERIALS AND METHODS: In vitro, 8000 rabbit vascular smooth muscle cells (rVSMC) where transfected with a liposomal carrier (TfX50) with 100 ng of decoy and scrambled ODN. Inhibition of proliferation was measured using a MTT assay after 24 hours in comparison to control. In vivo, 22 male New Zealand White rabbits were fed a 1% cholesterol diet and received denudation of both common iliac arteries with a 3 mm balloon catheter to induce an arterial stenosis. Four weeks after stenosis induction, local application of NF-kappa B in two different concentrations (1 mug: n = 14; 10 mug: n = 8) was performed randomly on one common iliac artery. Scrambled oligonucleotides without specific binding capacities were injected into the contralateral side. The channeled balloon catheter allows simultaneous balloon dilation (8 atm) of the stenosis and local application of a drug solution (2 atm). Four weeks after local drug delivery the animals were killed and the vessels were excised and computerized morphometric measurements were performed. RESULTS: NF-kappa B decoy ODN but not scrambled ODN inhibited proliferation of rVSMC in vitro. Following local ODN application in the animals, no acute vascular complications were seen. NF-kappa B ODN resulted in a statistically non significant reduction of neointimal area compared to the control group. The neointimal area was 0.97 mm(2) using 1 mug NF-kappa B ODN compared to 0.98 mm(2) in the control group. The higher dose resulted in a neointimal area of 0.97 mm(2) compared to 1.07 mm(2) at the control side. CONCLUSIONS: Local drug delivery of NF-kappa B ODN using the "channeled balloon" catheter could not reduce neointimal hyperplasia in stenostic rabbit iliac arteries. Application modalities have to be improved to enhance the effect of the local application to prevent restenosis after balloon angioplasty.

Angioplasty, Balloon↗