Atrial linear lesions: feasibility using cryoablation.

BACKGROUND: Long linear lesions are created in the left atrium to modify the atrial substrate, thereby curing atrial fibrillation. The creation of long linear left atrial lesions using radiofrequency (RF) ablation is time consuming and difficult. Furthermore, it might result in significant complications. Cryoablation might overcome some of the disadvantages of RF ablation. Therefore, the aim of our study was to assess whether the creation of a long linear lesion is possible using cryotherapy. METHODS: A right atrial septal linear lesion was created in six pigs (median weight: 50 kg; range: 40-60 kg). The ablation procedure was performed with a 7-F Freezor cryocatheter. The nonfluoroscopic mapping system LocaLisa was used as a navigation tool. At each point, freezing was maintained at the lowest attainable temperature (-75 degrees C) for 4 minutes. The CARTO system was used for the evaluation of the linear lesions. Furthermore, all animals were sacrificed immediately after the ablation procedure and a postmortem examination of the lesions was performed. Additionally, an analysis of the amplitudes of the intracardiac electrograms registered via the ablation catheter was performed before and after the ablation procedure. RESULTS: A right atrial septal linear lesion could be created successfully in all six pigs. For the performance of this ablation line, a median number of 16 cryoapplications (range, 11-26) was necessary. The amplitudes of the intracardiac electrograms registered via the ablation catheter decreased significantly after ablation. The CARTO bipolar voltage map revealed very low potentials along the ablation line and showed a sharply demarcated ablation area at the septum in all pigs. Further analysis of the CARTO map revealed an incomplete conduction block in all cases. Most of the pigs had a small gap close to the fossa ovalis. The postmortem examination of 2,3,5-triphenyl-tetrazolium chloride-stained specimens showed sharply demarcated lesions without any ulcerations. There were no major complications during the procedure. CONCLUSIONS: The creation of long linear lesions using cryoablation is feasible and safe. Lesion characteristics are different and more favorable than those created by RF. However, the aim of creating a transmural lesion and a complete conduction block remains an unsolved problem even with current cryoablation techniques. Nevertheless, growing experience and technical improvements might overcome some of the current limitations of this new technique.

Animals↗

Diagnostic accuracy of noninvasive coronary imaging using 16-detector slice spiral computed tomography with 188 ms temporal resolution.

OBJECTIVES: The aim of our study was to evaluate the diagnostic accuracy of 16-multi-detector spiral computed tomography (MDCT) with 188 ms temporal resolution. BACKGROUND: Because of rapid technical innovations, MDCT coronary imaging has significantly improved in the last five years. Recent results indicate a high diagnostic accuracy, especially in patients with clinical suspicion of coronary artery disease (CAD). METHODS: A total of 72 consecutive patients (30 women, 42 men, age 64 +/- 10 years) scheduled for invasive coronary angiography (ICA) because of suspected CAD were additionally studied by MDCT (Sensation 16 Speed 4D, Siemens, Forchheim, Germany). Thirty-seven of 72 patients (51%) received an additional beta-blockade before MDCT because of heart rates >65 beats/min. The MDCT scans were analyzed regarding the presence of coronary artery lesions. Results were compared with ICA. RESULTS: All 72 scans showed diagnostic image quality (heart rate: 64.1 +/- 9.2 beats/min, calcium mass: 86 +/- 156 mg). Thirteen coronary segments were evaluated in each patient. Sixty-two of 936 (6.6%) segments showed a nondiagnostic image quality. All segments were included in the analysis. A total of 117 relevant lesions (diameter stenosis >50%) were detected using ICA, and 96 of 117 (82%) were detected by MDCT. Sensitivity, specificity, and positive and negative predictive values for the whole study group were as follows: 82%, 98%, 87%, and 97%, respectively. The correct clinical diagnosis of presence or absence of significant CAD was obtained in 65 of 72 (90%) patients. All stenoses were detected by MDCT in 52 of 72 (72%) patients. CONCLUSIONS: Our results indicate a high diagnostic accuracy of 16-slice MDCT with improved temporal resolution.

Adult↗

Addition of a defibrillation electrode in the low right atrium to a right ventricular lead does not reduce ventricular defibrillation thresholds.

Transvenous unipolar active can defibrillation systems have proven to be effective in treating ventricular tachyarrhythmias. However, a further reduction of ventricular defibrillation thresholds (V-DFT) would increase the longevity, reduce the size of pulse generators, and help to avoid additional leads in patients with inacceptable high V-DFTs. In a finite difference computer model, the extension of the right ventricular (RV) defibrillation coil into the low right atrium led to a 40% reduction of unipolar V-DFT. To evaluate this finding, we conducted a prospective, randomized study in 11 patients receiving an ICD. Extension of the RV electrode was simulated by adding a second coil placed in the low right atrium with the same polarity. Using a binary search protocol, V-DFT was determined with and without the additional electrode in each patient. Total shock impedance was significantly lower in the two coil (low RA) configuration, compared to the single coil (RV) configuration. Corresponding values were 49.9 +/- 6.7 Ohm and 61.1 +/- 9.3 Ohm, respectively (P < 0.01, paired t-test). However, there was no reduction, but even a nonsignificant increase in V-DFTs. Mean V-DFT in the RV configuration was 12.0 +/- 5.6 J and 16.3 +/- 7.8 J in the low RA configuration (P = 0.09, paired t-test). Despite a reduction in total impedance, the addition of a defibrillation coil in the low right atrium does not reduce ventricular defibrillation thresholds.

Aged↗

Long-term experience with subcutaneous ICD leads: a comparison among three different types of subcutaneous leads.

ICDs provide protection against sudden cardiac death in patients with life-threatening arrhythmias. Nevertheless, efficacy of defibrillation remains an important issue to guarantee the future safety of patients who receive an ICD. There is a significant number of patients who need an additional subcutaneous lead to obtain a defibrillation safety margin of at least 10 J between the maximum output of the ICD and the energy needed for ventricular defibrillation. However, few data exists about the long-term performance of different types of subcutaneous leads. Therefore, the aim of this study was to analyze the long-term experience with three different types of subcutaneous leads. The study included 132 patients (109 men, 23 women; mean age 59.8 years [SD +/- 10.7 years]). All of them received a subcutaneous lead in addition to a single chamber or dual chamber ICD between October 1990 and April 2002. Two patients received a second subcutaneous lead after the first lead had been removed so that a total of 134 subcutaneous leads were evaluated. Inclusion criteria for the implantation of an additional subcutaneous lead were (1) unsuccessful ventricular defibrillation at implant without a subcutaneous lead, (2) insufficient safety margin (< 10 J) between the maximum output of the ICD and the energy needed for ventricular defibrillation, or (3) clinical evaluation of a new subcutaneous lead (Medtronic 13014). There were no significant differences between the three study groups with regard to age, sex, underlying cardiac disease, left ventricular ejection fraction, NYHA class assessment and clinical arrhythmia. The results of the DFT testing during follow-up (prehospital discharge test and 1 and 3 years) were compared to the baseline value obtained during the implantation procedure. All lead related complications were analyzed. Eighty-two single element subcutaneous array electrodes (SQ-A1), 31 subcutaneous three-finger electrodes (SQ-A3), and 21 subcutaneous patch electrodes (SQ-P) were implanted during the study period. The median follow-up was 1,499 days (25th percentile: 798 days, 75th percentile: 1,976 days) in the SQ-A1 group, 2,209 days (25th percentile: 1,242 days, 75th percentile: 2,710 days) in the SQ-A3 group, and 1,419 days (25th percentile: 787 days, 75th percentile: 2,838 days) in the SQ-P group. None of the three groups had a significant change of the DFT during follow-up compared to baseline. Major complications occurred in six (7.3%) patients in group SQ-A1 and in two (9.5%) patients in group SQ-P. There were no major complications in group SQ-A3. Kaplan-Meier curves analyzing freedom from subcutaneous lead related complications did not show a significant difference between the three study groups (P = 0.16). SQ-A1, SQ-A3, and SQ-P leads provide stable DFTs during long-term follow-up. Major complications are rare. However, a careful follow-up including chest radiographs at regular intervals is needed to detect potentially fatal complications like lead fractures.

Defibrillators, Implantable↗

Efficacy of metoprolol and sotalol in the prevention of recurrences of sustained ventricular tachyarrhythmias in patients with an implantable cardioverter defibrillator.

ICDs provide protection against sudden cardiac death in patients with life-threatening ventricular arrhythmias. Nevertheless, most ICD recipients receive adjunctive antiarrhythmic drug therapy to reduce the number of recurrent episodes and ICD discharges. The aim of the study was to compare the efficacy of metoprolol and d,l-sotalol in preventing VT/VF recurrences in patients with an ICD in a prospective, randomized trial. One hundred patients (83 men, 17 women; mean age 59 years, SD +/- 11 years) were randomized to receive metoprolol or sotalol after implantation of an ICD. There were no significant differences between the two groups with regard to age, sex, underlying cardiac disease, left ventricular ejection fraction, NYHA class assessment and clinical arrhythmia. The median follow-up was 728 days (25th percentile: 530 days, 75th percentile: 943 days) in the metoprolol group and 727 days (25th percentile: 472 days, 75th percentile: 1,223 days) in the sotalol group (P = 0.52). Thirty-three patients treated with metoprolol and 30 patients receiving sotalol had at least one episode during the follow-up. Event-free survival curves were generated for the two treatment arms using the Kaplan-Meier method and showed no significant difference (P = 0.68). Eight patients treated with metoprolol and six patients treated with sotalol died during follow-up. Total mortality was not significantly different between the two study groups (P = 0.43). Metoprolol is as efficacious as sotalol in preventing VT/VF recurrences in patients with an ICD.

Defibrillators, Implantable↗

Is it safe to program a long tachycardia detection interval?

Implantable cardioverter defibrillator (ICD) therapy is used frequently in patients with "slow" ventricular tachycardia (VT). Hence, the tachycardia detection interval is programmed within the range of the physiologic heart rate, but this may cause serious problems. If a fast VT is converted to sinus tachycardia with a cycle length shorter than the tachycardia detection interval, the episode is not terminated and the success counter is not reset. If this happens repeatedly, therapies will be exhausted without termination of the episode. If VT recurs within such an episode, it will not be treated. This report describes a patient who died suddenly in a scenario similar to the one described. Although all documented VT/ventricular fibrillation episodes were terminated by the device, the episode was not terminated because of the ongoing supraventricular tachycardia. Therefore, no further therapies were available and the patient probably died of fast untreated VT. Programming of a long tachycardia detection interval is dangerous in currently available ICDs.

Aged↗