A new endocardial "over-the-wire" or stylet-driven left ventricular lead: first clinical experience.

Transvenous left ventricular (LV) leads are primarily inserted "over-the-wire" (OTW). However, a stylet-driven (SD) approach may be a helpful alternative. A new polyurethane-coated, unipolar LV lead can be placed either by a stylet or a guide wire, which can be inserted into the lead body from both ends. The multicenter OVID study evaluates the clinical performance of this new steroid- and nonsteroid eluting lead. The primary endpoint is the LV lead implant success rate after identification of the coronary sinus (CS). Secondary endpoints include complication rate, short- and long-term lead characteristics, overall procedure and LV lead placement duration, total fluoroscopy time, and lead handling characteristics ratings. To date, 96 patients with heart failure (68 +/- 9 years old, 76% men) are enrolled. The CS was identified in 95 patients and, in 85 (88.5%), the LV lead was successfully implanted. The final lead positioning was lateral in 41%, posterolateral in 35%, anterolateral in 18%, and great cardiac vein in 6% of patients. In 70%, the 85 successful implantations, both stylet-driven and guide-wire techniques were used, a stylet only was used in 22%, and a guide wire only in 8%. Mean overall duration of 85 successful procedures was 112 +/- 40 minutes, total fluoroscopy time 28 +/- 15 minutes, and the duration of LV lead placement was 35 +/- 29 minutes. During a 3-month follow-up, the loss of LV capture occurred in three and phrenic nerve stimulation in six patients. The mean long-term pacing threshold is 0.8 V/0.5 ms and pacing impedance is 550 Omega. The OVID data suggest that these new leads are safe and effective. The choice of both OTW and SD techniques during lead implantation offers greater procedural flexibility.

Adult↗

Effect of left ventricular function on long-term left ventricular pacing and sensing threshold.

BACKGROUND: The effect of left ventricular (LV) systolic function on the long-term left ventricular pacing and sensing threshold is unclear. METHODS AND RESULTS: We studied the effect of LV ejection fraction (LVEF) on the LV pacing and sensing threshold in 56 patients (mean age: 70.2 +/- 10.5 years) underwent permanent LV pacing using a self-retaining coronary sinus lead (Model 1055 K, St Jude Medical, USA). In 49 patients, the LV lead was implanted for conventional pacemaker indication (sick sinus syndrome = 14, heart block = 26 or slow atrial fibrillation = 9). The remaining 7 patients were implanted for congestive heart failure. The LV pacing and sensing threshold, and lead impedance were compared between patients with LVEF <40% (Group 1, n = 28) and LVEF >40% (Group 2, n = 28) during implant and at 3-month follow up. The LV pacing lead was successfully implanted in all patients without any lead dislodgement on follow-up. At implant, Group 1 patients had a significant lower R wave amplitude, but similar LV pacing threshold and lead impedance as compared to Group 2. However, at 3-month follow-up, Group 1 patients had a significantly higher LV pacing threshold compared to Group 2 patients. There were no significant differences in the sensing threshold and lead impedance between the two groups. Furthermore, there was also a significant interval increase in LV pacing threshold in Group 1 patients (0.94 +/- 0.12 V) after 3 months, but not in Group 2 patients (0.16 +/- 0.08 V, p < 0.01). CONCLUSIONS: The results of this study suggest that the LV systolic function has a significant impact on the long-term LV pacing threshold. The long-term left ventricular pacing threshold in patients with left ventricular systolic dysfunction increased after implant and was higher than patients with normal left ventricular systolic function.

Aged↗

Pacing of the atria in sick sinus syndrome trial: preventive strategies for atrial fibrillation.

This study examines the effects of various atrial lead positions in physiological pacing on the incidence of AF in patients with sick sinus syndrome. The lead is implanted in the RA free wall, in the RA appendage, near the coronary sinus ostium (CSO) or, in dual site RA pacing, in the appendage and the CSO. Since CSO and dual site right atrial pacing aim at modifying the pathological substrate, pacing of two-thirds of all cardiac cycles is attempted by adapting the basic rate and the rate response option. The results of this study are expected to assist in the development of guidelines for the placement of atrial pacing leads in sick sinus syndrome.

Atrial Fibrillation↗

The influence of concomitant drug therapy on the efficacy of atrial overdrive stimulation for prevention of atrial tachyarrhythmias.

Data from the completed "Suppression of Atrial Fibrillation by DDD+ Overdrive Pacing with Inos2 CLS (closed-loop system) Pacemakers" multicenter trial were retrospectively evaluated to examine the influence of concomitant antiarrhythmic drugs on the clinical success of conventional single site right atrial overdrive pacing compared with DDD pacing. The DDD+ overdrive algorithm provided > 90% atrial pacing at a rate slightly above the intrinsic atrial rate. Seventy-five patients with conventional pacing indications and paroxysmal, recurrent atrial tachyarrhythmia have completed the study. They were randomized to 6 months of DDD or DDD+ pacing, followed by mode crossover and an additional 6-month follow-up in the alternate mode. The incidence of atrial tachyarrhythmia during each period was compared using data on sustained (> 60 s) mode switch episodes stored in the pacemaker memory. A stable antiarrhythmic drug regimen was allowed during the study. beta-Adrenergic blockers and Class III antiarrhythmics, prescribed to 54.7% and 40.0% of patients respectively, were linked to minimal or no benefit of overdrive pacing compared with DDD pacing. In contrast, patients untreated with beta-adrenergic blockers or Class III drugs had a significant reduction in atrial tachyarrhythmia burden of > 5 hours/patient per week (P < 0.05) during overdrive. Changes with Class I and Class IV antiarrhythmic drugs, prescribed to 18.7% and 13.3% of patients, respectively, were insignificant. Our data indicate that clinical trials that prohibit the use of beta-adrenergic blockers may record more favorable outcomes with dynamic atrial overdrive algorithms versus conventional DDDR pacing, than studies allowing concomitant beta-adrenergic blockade.

Adrenergic beta-Antagonists↗

Spontaneous conversion of permanent atrial fibrillation into stable sinus rhythm after 17 months of biventricular pacing.

A 68-year-old woman with drug refractory congestive heart failure (NYHA Class III, ejection fraction 35%, moderate to severe mitral regurgitation) and permanent atrial fibrillation uninterrupted for >3 years, underwent implantation of a biventricular pacing system. Seventeen months later, atrial fibrillation spontaneously converted into sinus rhythm, which has been maintained for more than 6 months (to date).

Aged↗