PubMed Health⌕ Search

Biomedical subjects

Klaus Scheffler

Publications and source records attributed to Klaus Scheffler.

41 records · Page 3Linked to original sources

Optimization of signal behavior in the transition to driven equilibrium in steady-state free precession sequences.

A new technique to avoid the initial signal fluctuations in steady-state free precession (SSFP)-sequences, such as trueFISP, FIESTA, and refocused FFE, is presented. The "transition into driven equilibrium" (TIDE) sequence uses modified flip angles over the initialization phase of a SSFP experiment, which not only avoids image artifacts but also improves the signal-to-noise ratio (SNR) and contrast behavior compared to conventional approaches. TIDE is demonstrated to be robust against variations of T(1) and T(2), and leads to a monotonous signal evolution for off-resonance spins. The basic principles can also be applied repetitively to optimize continuous 3D acquisitions.

Head↗

Single-breathhold 3D-trueFISP cine cardiac imaging.

Cardiac MRI function measurements are typically based on multiple breathhold 2D sequences to acquire images of the entire heart. In the present study, the feasibility of a cine 3D TrueFISP technique in which several complete volumetric measurements may be obtained during a single breathhold is demonstrated. In contrast to 3D FLASH, the TrueFISP sequence offers an excellent contrast between the myocardium and the intraventricular cavity without the use of contrast agent. An ECG-gated 3D cine TrueFISP sequence was implemented with a repetition time of 2.4-2.8 ms, which allows imaging of the complete heart within a single breathhold throughout 20-46 heartbeats with a 3D frame rate of 8-13 volumes per cardiac cycle and a spatial resolution of about 1.5 x 3.5 x 3.5 mm(3). Breathhold volumetric cine imaging with the 3D TrueFISP technique holds promise for rapid and accurate evaluation of the cardiac regional wall motion and the calculation of cardiac volume and ejection fraction.

Artifacts↗

Homogeneous preparation encoding (HoPE) in multislice imaging.

Fast magnetization preparation techniques acquire a series of echoes after a single magnetization preparation. If these echoes are acquired from different slices using a multislice technique the change in the preparation state of the echoes due to relaxation effects leads to different contrast modification for each slice. Encoding different preparation states along the phase-encoding direction of each slice instead of acquiring each slice in a different preparation state is introduced as a general concept to obtain images of identical contrast and point-spread function. This can be realized either by cycling the slice excitation order several times over the total number of repetitions or by moving the point of time at which the preparation is applied within each repetition. One possible application of this method is chemical shift selective fat saturation imaging. A homogeneous fat suppression across a multislice volume could be achieved using a FLASH sequence at a repetition time of TR = 145 ms, including a single fat saturation preparation. Conventional fat saturated spin-echo imaging at any TR can be accelerated significantly by reducing the number of applied preparations per repetition. A further application of the homogeneous preparation encoding (HoPE) method is described that encodes the spatial self-saturation of the multislice excitation order homogeneously in all slices. Only a reduced number of slices of the total volume are excited in each repetition and the slice excitation order is continuously moved along the imaging volume. This method is applied for time of flight (TOF) imaging. Using a TONE-like series of flip angles for the slice excitations of each repetition homogeneous TOF images can be obtained on the basis of a multislice acquisition.

Abdomen↗

Signal behavior in continuously ramped 2D TrueFISP for whole-body imaging.

A fast and robust imaging technique was developed based on a single-slice TrueFISP acquisition using a slice excitation frequency that is incremented, or spatially "ramped," with each repetition. The short acquisition time of single slices allows artifact-free imaging during free breathing, which demonstrates the potential use of this technique for whole-body screening. Overlapping positioning of consecutively acquired slices was used to provide gapless volume coverage in free-breathing measurements. The image contrast of ramped TrueFISP was analyzed in detail using simulations and experiments. A high ramp speed results in an increased overall signal intensity and in a modification of the known T(2)/T(1) contrast towards a proton density-weighted contrast. A further increase in imaging speed is achieved with z-interleaved phase-encoding trajectories based on weighted transitions between adjacent views.

Contrast Media↗

Amplitopicity of the human auditory cortex: an fMRI study.

Whereas specialized frequency-encoding patterns in the human auditory cortex are generally accepted, termed tonotopicity, a similar principle of intensity encoding--amplitopicity--is debated controversially. This functional magnetic resonance imaging study describes the relationship of the activation volume and the spatial distribution of activated clusters under different sound pressure levels (SPL) across the temporal plane including the transverse temporal gyrus (TTG). Nine healthy subjects with no hearing deficiencies were investigated using an echo-planar imaging technique at 1.5 T. A boxcar stimulation paradigm was applied with a 5-Hz pulsed sine tone of 1000 Hz frequency at three SPLs of 70, 82, and 90 dB. Linear cross-correlation analysis (correlation coefficient > 0.3 corresponding to P < 0.08) of the functional data set revealed bilateral BOLD response within the auditory cortex of the nine subjects with moderate increase of activation volume for higher sound pressure levels. With increasing sound pressure a two-dimensional drift of cortical activation was observed (a) from the ventral to the dorsal edge and (b) from lateral to medial parts of TTG. This latero-medial drift therefore mimics the well-accepted principle of tonotopy for frequency-encoding neurons. This study demonstrates the existence of an amplitopic pattern of intensity-encoding neuronal clusters that in part resembles the tonotopic distribution of frequency-encoding neurons. This finding has to be integrated into the understanding of the auditory organization for the interpretation of higher auditory functions such as sound perception or speech.

Acoustic Stimulation↗