PubMed Health⌕ Search

Biomedical subjects

Kohei Maruyama

Publications and source records attributed to Kohei Maruyama.

7 recordsLinked to original sources

Determination of microsatellite repeats in the human thyroid peroxidase (TPOX) gene using an automated gene analysis system with nanoscale engineered biomagnetite.

The number of repeat in the microsatellite region (AATG)(5-14) of the human thyroid peroxidase gene (TOPX) was determined using an automated DNA analysis system with nano-scale engineered biomagnetite. Thermal melting curve analysis of DNA duplexes on biomagnetite indicated that shorter repeat sequences (less than 9 repeats) were easily discriminated. However, it was difficult to determine the number of repeats at more than nine. In order to improve the selectivity of this method for the longer repeats, a "double probe hybridization assay" was performed in which an intermediate probe was used to replace a target repeat sequence having more than 9 repeats with a shorter sequence possessing less than 9 repeats. Thermal probe melting curve analyses and Tm determination confirmed that the target with 10 repeats was converted to 5 repeats, 11 repeats converted to 4 and 12 to 3, respectively. Furthermore, rapid determination of repeat numbers was possible by measuring fluorescence intensities obtained by probe dissociation at 56 and 66 degrees C, and 40, 60 and 80 degrees C for signal normalization.

Ferrosoferric Oxide↗

Detection of epidermal growth factor receptor (EGFR) mutations in non-small cell lung cancer (NSCLC) using a fully automated system with a nano-scale engineered biomagnetite.

A fully automated system using nano-scale engineered biomagnetite was developed to detect mutations in the epidermal growth factor receptor (EGFR) gene in non-small cell lung cancer (NSCLC). Bacterial magnetic particles (BacMPs) were isolated from the magnetic bacterium Magnetospirillum magneticum AMB-1 and conjugated to streptavidin. Biotin-labeled target PCR products were then captured with the BacMPs, hybridized with the detection probe and detected by fluorescence signaling. The process was performed using a newly designed automated processor equipped with an XYZ mobile arm containing a 96-way automated pipetter, reagent dispenser and fluorescence detector. Two types of somatic mutations (in-frame deletions and point substitutions) in the EGFR gene were successfully identified within 3.5h using this system, suggesting that this system could be used in clinical tests of EGFR gene mutations in lung cancer, and potentially other cancer, patients. Additionally, a very low mutation rate could be detected in these samples.

Carcinoma, Non-Small-Cell Lung↗

Capture and release of DNA using aminosilane-modified bacterial magnetic particles for automated detection system of single nucleotide polymorphisms.

Bacterial magnetic particles (BMPs) were modified with 3-[2-(2-aminoethylamino)-ethylamino]-propyltrimethoxysilane (AEEA) to produce a dense amine surface. Modification of BMPs in a toluene solution resulted in an increased amine yield, and approximately 11.3 x 10(4) surface amines were detected on a single particle. The modified BMPs were capable of efficient electrostatic capture of DNA. The maximum amount of DNA captured on 10 microg of aminosilane-modified BMPs was 600 ng. A 10 mM phosphate buffer effectively released the captured DNA. This efficiency was dramatically enhanced by incubation at 80 degrees C and DNA recovery from aminosilane-modified BMPs approached 95%. DNA extraction from whole blood using these modified BMPs, followed by PCR, was successfully performed. Furthermore, automated single nucleotide polymorphism (SNP) detection of the aldehyde dehydrogenase 2 (ALDH2) was demonstrated.

Bacterial Proteins↗

Single nucleotide polymorphism detection in aldehyde dehydrogenase 2 (ALDH2) gene using bacterial magnetic particles based on dissociation curve analysis.

Single nucleotide polymorphism (SNP) detection for aldehyde dehydrogenase 2 (ALDH2) gene based on DNA thermal dissociation curve analysis was successfully demonstrated using an automated system with bacterial magnetic particles (BMPs) by developing a new method for avoiding light scattering caused by nanometer-size particles when using commercially available fluorescent dyes such as FITC, Cy3, and Cy5 as labeling chromophores. Biotin-labeled PCR products in ALDH2, two allele-specific probes (Cy3-labeled detection probe for ALDH2*1 and Cy5-labeled detection probe for ALDH2*2), streptavidin-immobilized BMPs (SA-BMPs) were simultaneously mixed. The mixture was denatured at 70 degrees C for 3 min, cooled slowly to 25 degrees C, and incubated for 10 min, allowing the DNA duplex to form between Cy3- or Cy5-labeled detection probes and biotin-labeled PCR products on SA-BMPs. Then duplex DNA-BMP complex was heated to 58 degrees C, a temperature determined by dissociation curve analysis and a dissociated single-base mismatched detection probe was removed at the same temperature under precise control. Furthermore, fluorescence signal from the detection probe was liberated into the supernatant from completely matched duplex DNA-BMP complex by heating to 80 degrees C and measured. In the homozygote target DNA (ALDH2*1/*1 and ALDH2*2/*2), the fluorescence signals from single-base mismatched were decreased to background level, indicating that mismatched hybridization was efficiently removed by the washing process. In the heterozygote target DNA (ALDH2*1/*2), each fluorescence signals was at a similar level. Therefore, three genotypes of SNP in ALDH2 gene were detected using the automated detection system with BMPs.

Aldehyde Dehydrogenase↗

Development and evaluation of an automated workstation for single nucleotide polymorphism discrimination using bacterial magnetic particles.

We designed an automated workstation for magnetic particle-based single nucleotide polymorphism (SNP) discrimination of ALDH genotypes. Bacterial magnetic particles (BMPs) extracted from Magnetospirillum magneticum AMB-1 were used as DNA carriers. The principle for SNP discrimination in this study was based on fluorescence resonance energy transfer (FRET) between FITC (donor) and POPO-3 (acceptor) bound to double-stranded DNA. The workstation is equipped with a 96-way automated pipetter which collects and dispenses fluids as it moves in x- and z-directions. The platform contains a disposable tip rack station, a reagent vessel serving as a stock for POPO-3 and FITC-labeled probes and a reaction station for a 96-well microtiter plate. BMPs were collected by attaching a neodymium iron boron sintered (Nd-Fe-B) magnet on the bottom of the microtiter plate. This system permits the simultaneous heating and magnetic separation of 96 samples per assay. The genotypes ALDH2*1 and ALDH2*2 were discriminated by calculating the relative fluorescence intensities on BMPs.

Aldehyde Dehydrogenase↗

Single-nucleotide polymorphism analysis using fluorescence resonance energy transfer between DNA-labeling fluorophore, fluorescein isothiocyanate, and DNA intercalator, POPO-3, on bacterial magnetic particles.

To develop an analytical system for single-nucleotide polymorphisms (SNPs), the fluorescence resonance energy transfer (FRET) technique was employed on a bacterial magnetic particle (BMP) surface. A combination of fluorescein isothiocyanate (FITC; excitation 490 nm/emission 520 nm) labeled at the 5' end of DNA and an intercalating compound (POPO-3, excitation 534 nm/emission 570 nm) was used to avoid the interference from light scattering caused by nanoparticles. After hybridization between target DNA immobilized onto BMPs and FITC-labeled probes, fluorescence from POPO-3, which was excited by the energy from the FITC, was detected. The major homozygous (ALDH2*1), heterozygous (ALDH2*1/*2), and minor homozygous (ALDH2*2) genotypes in the blood samples were discriminated by this method. The assay described herein allows for a simple and rapid SNP analysis using a fully automated system.

Bacterial Proteins↗

Fully automated DNA extraction from blood using magnetic particles modified with a hyperbranched polyamidoamine dendrimer.

Bacterial and artificial magnetic particles were modified using a polyamidoamine (PAMAM) dendrimer and outer shell amines determined. Bacterial magnetic particles were the most consistently modified. Transmission electron microscopic (TEM) analysis showed that the artificial magnetic particles were structurally damaged by the modification process including sonication. Furthermore, laser particle analysis of the magnetite also revealed damage. Small quantities of dendrimer-modified bacterial magnetic particles were used to extract DNA from blood. The efficiency of DNA recovery was consistently about 30 ng of DNA using 2-10 microg of dendrimer-modified bacterial magnetite. This technique was fully automated using newly developed liquid handling robots and bacterial magnetic particles.

Journal Article↗