Radiogenic risks from hysterosalpingography.

The aim of this study was to determine ovarian dose, effective dose and associated radiogenic risks from hysterosalpingography (HSG), and to provide data for the estimation of radiogenic risks related to HSG studies performed in any laboratory. The fluoroscopy time, number of radiographs taken and entrance surface dose were measured in a series of 78 consecutive patients undergoing HSG as part of their infertility work-up. Organ-dose values per radiograph and per minute of fluoroscopy were separately determined using an anthropomorphic phantom and thermoluminescence dosimetry. The radiogenic risk for deleterious effects on a possible future embryo and the radiogenic risk for cancer induction on the patient undergoing HSG were estimated. The average HSG procedure in our laboratory involves a mean fluoroscopic time of 0.3 min and a mean number of radiographs of 3.2. The dose to female gonads from an average HSG procedure was 2.7 mGy and the patient effective dose was 1.2 mSv. The risk for radiogenic anomalies in a future embryo of the woman undergoing an average HSG procedure and the risk for radiogenic fatal cancer induction in the exposed woman were estimated to be less than 10(-3) of the correspondent nominal risks. Radiation risks from a typical HSG are low, but they may be elevated if fluoroscopic and/or radiographic exposures are prolonged for any reason. Present data allow the estimation of radiogenic risks associated with HSG procedures performed in other laboratories with use of different equipment, screening time and number of radiographs taken.

Abnormalities, Radiation-Induced↗

Ultrasound velocity through the cortex of phalanges, radius, and tibia in normal and osteoporotic postmenopausal women using a new multisite quantitative ultrasound device.

RATIONALE AND OBJECTIVES: To assess a new multisite quantitative ultrasound (QUS) device (Sunlight Omnisense 7000 S) suitable for the measurement of speed of sound (SOS) in the phalanges, radius, and tibia. METHODS: The study group consisted of 270 healthy Caucasian postmenopausal patients (mean age: 60.0 +/- 7.6 years) and 53 Caucasian postmenopausal patients (mean age: 67.2 +/- 7.4 years) with osteoporotic fractures. Measurements of SOS and bone mineral density (BMD) were carried out in all subjects. RESULTS: Intraobserver in vivo short-term precision was on average 0.76% for the radius, 0.47% for the tibia, and 1.54% for the phalanges. The interobserver precision ranged from 0.77% to 2.39%. Measurements of SOS at the 3 skeletal sites were significantly correlated (r = 0.28-0.44; P < 0.001). Significant correlations were found between SOS at all sites and BMD (r = 0.21-0.41; P < 0.001). The odds ratio for fracture prediction for SOS was 1.47 for tibia, 1.69 for radius, and 2.69 for phalanx. The corresponding odds ratios for BMD at the lumbar spine, femoral neck, and total hip ranged from 2.08 to 3.26. The area under the receiver operating characteristic curve ranged from 0.611 to 0.741 for SOS measurements and from 0.745 to 0.797 for BMD measurements. CONCLUSIONS: The Omnisense multisite QUS device exhibits reproducible performance. Among the QUS variables, the phalangeal SOS provides the best discrimination of fracture patients.

Aged↗

Occupational exposure from common fluoroscopic projections used in orthopaedic surgery.

BACKGROUND: Personnel assisting in or performing fluoroscopically guided procedures may be exposed to high doses of radiation. Accurate occupational dosimetric data for the orthopaedic theater staff are of paramount importance for practicing radiation safety. METHODS: Fluoroscopic screening was performed on an anthropomorphic phantom with use of four projections common in image-guided orthopaedic surgery. The simulated projections were categorized, according to the imaged anatomic area and the beam orientation, as (1) hip joint posterior-anterior, (2) hip joint lateral cross-table 45 degrees, (3) lumbar spine anterior-posterior, and (4) lumbar spine lateral 90 degrees. The scattered air kerma rate was measured on a grid surrounding the operating table. For each grid point, the effective dose, eye lens dose, and face skin dose values, normalized over the tube dose area product, were derived. For the effective dose calculations, three radiation protection conditions were considered: (1) with the exposed personnel using no protection measures, (2) with the exposed personnel wearing a 0.5-mm lead-equivalent protective apron, and (3) with the exposed personnel wearing both an apron and a thyroid collar. Maximum permissible workloads for typical hip, spine, and kyphoplasty procedures were derived on the basis of compliance with effective dose, eye lens dose, and skin dose limits. RESULTS: We found that the effective dose, eye lens dose, and face skin dose to an orthopaedic surgeon wearing a 0.5-mm lead-equivalent apron will not exceed the corresponding limits if the dose area product of the fluoroscopically guided procedure is <0.38 Gy m (2). When protective eye goggles are also worn, the maximum permissible dose area product increases to 0.70 Gy m (2), while the additional use of a thyroid shield allows a workload of 1.20 Gy m (2). The effective dose to the orthopaedic surgeon working tableside during a typical hip, spine, kyphoplasty procedure was 5.1, 21, and 250 micro Sv, respectively, when a 0.5-mm lead-equivalent apron alone was used. The additional use of a thyroid shield reduced the effective dose to 2.4, 8.4, and 96 micro Sv per typical hip, spine, and kyphoplasty procedure, respectively. CONCLUSIONS: The levels of occupational exposure vary considerably with the type of fluoroscopically assisted procedure, staff positioning, and the radiation protection measures used. The data presented in the current study will allow for accurate estimation of the occupational dose to orthopaedic theater personnel.

Fluoroscopy↗

The predictive role of serum and bronchoalveolar lavage cytokines and adhesion molecules for acute respiratory distress syndrome development and outcome.

BACKGROUND: The predictive role of many cytokines and adhesion molecules has not been studied systematically in acute respiratory distress syndrome (ARDS). METHODS: We measured prospectively tumour necrosis factor alpha (TNF-alpha), interleukin (IL)-1, soluble vascular adhesion molecule-1 (VCAM-1) and soluble intercellular adhesion molecule-1 (ICAM-1) in serum and bronchoalveolar lavage fluid (BALF) within 2 hours following admission, in 65 patients. The patients were divided into: those fulfilling the criteria for ARDS (n = 23, group A), those who were pre-ARDS and who developed ARDS within 24 hours (n = 14, group B), and those on pre-ARDS but who never developed ARDS (n = 28, group C). RESULTS: All the measured molecules were only found at higher levels in the serum of patients that died either with or without ARDS (P < 0.05 - P < 0.0001). Patients at risk exhibited a good negative predictive value (NPV) of the measured molecules for ARDS development both in their serum (89 to 95%) and BALF (86 to 92%) levels. In contrast to BALF, serum levels of IL-1 and adhesion molecules exhibited a good NPV (68 to 96%), sensitivity (60 to 88%) and survival specificity (74 to 96%) in all groups. All molecules in serum and BALF IL-1 were correlated with the APACHE II (P < 0.05 - P < 0.0001). Serum and BALF IL-1 as well as BALF TNF-alpha were negatively correlated to PaO2/FiO2 (all P < 0.05). CONCLUSIONS: The studied molecules have good NPV for ARDS development both in serum and BALF. Serum rather than BALF levels seem to be related to outcome.

Acute Disease↗

Conceptus radiation dose and risk from chest screen-film radiography.

The objectives of the present study were to (a) estimate the conceptus radiation dose and risks for pregnant women undergoing posteroanterior and anteroposterior (AP) chest radiographs, (b) study the conceptus dose as a function of chest thickness of the patient undergoing chest radiograph, and (c) investigate the possibility of a conceptus to receive a dose of more than 10 mGy, the level above which specific measurements of conceptus doses may be necessary. Thermoluminescent dosimeters were used for dose measurements in anthropomorphic phantoms simulating pregnancy at the three trimesters of gestation. The effect of chest thickness on conceptus dose and risk was studied by adding slabs of lucite on the anterior and posterior surface of the phantom chest. The conceptus risk for radiation-induced childhood fatal cancer and hereditary effects was calculated based on appropriate risk factors. The average AP chest dimension (d(a)) was estimated for 51 women of childbearing age from chest CT examinations. The value of d(a) was estimated to be 22.3 cm (17.4-27.2 cm). The calculated maximum conceptus dose was 107 x 10(-3) mGy for AP chest radiographs performed during the third trimester of pregnancy with maternal chest thickness of 27.2 cm. This calculation was based on dose data obtained from measurements in the phantoms and d(a) estimated from the patient group. The corresponding average excess of childhood cancer was 10.7 per million patients. The risk for hereditary effects was 1.1 per million births. Radiation dose for a conceptus increases exponentially as chest thickness increases. The conceptus dose at the third trimester is higher than that of the second and first trimesters. The results of the current study suggest that chest radiographs carried out in women at any time during gestation will result in a negligible increase in risk of radiation-induced harmful effects to the unborn child. After a properly performed maternal chest X-ray, there is no need for individual conceptus dose estimations.

Abnormalities, Radiation-Induced↗

Broadband ultrasound attenuation imaging: algorithm development and clinical assessment of a region growing technique.

This paper presents a computerized method for the selection of an irregular region of interest (ROI) in broadband ultrasound attenuation (BUA) images. A region growing algorithm searches an initial region in the posterior part of the calcaneus until the pixel with the lowest attenuation value is found; this is the starting seed. Then, the algorithm evaluates the values of the eight pixels neighbouring the starting seed. Pixels that have the closest value to the starting seed are accepted. This procedure is the first processing level. The procedure is repeated for the group of pixels neighbouring those accepted from the previous processing level. The algorithm ceases when the number of accepted pixels reaches a user-specified number. The clinical part of this study compares measurements of BUA at an automatic ROI implemented on a quantitative ultrasound imaging device, defined as the circular region of lowest attenuation in the posterior part of the calcaneus, and at irregular ROIs of various sizes generated by the algorithm developed in this study. The algorithm was applied to BUA images obtained from 24 post-menopausal women with hip fractures and 26 age-matched healthy female subjects. The use of the irregular ROI with a size of 2400 pixels is proposed because that region yielded better clinical results compared to irregular ROIs with different size and the circular automatic ROI.

Algorithms↗

Patient effective radiation dose and associated risk from transmission scans using 153Gd line sources in cardiac spect studies.

The aim of the present study was to determine the contribution of transmission measurements acquisition to total patient effective dose from cardiac SPECT studies. A dual-head L-shaped gamma camera equipped with a transmission scan acquisition system based on two 153Gd line sources was used to simulate transmission measurements acquisition exposure on an anthropomorphic phantom. Thermoluminescence dosimeters were used to directly monitor the dose to 550 measuring points in the phantom. The effective dose and associated risk from transmission scans acquisition were estimated and compared to those associated to the radiopharmaceutical injected. The maximum effective dose from a typical transmission measurements acquisition was 1.3 microSv and 1.9 microSv for male and female patients, respectively. The contribution of the typical transmission scans acquisition to total patient radiation risk from a cardiac SPECT study is less than 10(-3). Thus, radiation exposure may not be considered as a limiting factor for the clinical application of attenuation correction methods based on transmission measurements in cardiac SPECT.

Gadolinium↗

Assessment of patient effective radiation dose and associated radiogenic risk from extracorporeal shock-wave lithotripsy.

The aim of the present study was to calculate patient effective dose and associated radiogenic risk from fluoroscopy guided extracorporeal shock-wave lithotripsy procedures. Fluoroscopy required during extracorporeal shock-wave lithotripsy was classified in two types identified by beam orientation: antero-posterior and 30 degrees anterior-oblique projected exposures. Duration of each exposure was monitored in 124 patients undergoing extracorporeal shock-wave lithotripsy treatment for ureteral stones. The dose from a kidney-ureter-bladder radiograph and the dose per min of fluoroscopy along antero-posterior and anterior-oblique projections were measured at 13 organs/tissues using an anthropomorphic phantom and thermoluminescence dosimetry. A radio-opaque object was placed in the phantom to simulate an ureteral stone at the proximal and distal ureter. The total effective dose in male and female patients with proximal ureteral stones was 1.71 mSv and 1.82 mSv, respectively. The corresponding values for male and female patients with distal ureteral stones was 0.76 mSv and 1.62 mSv, respectively. In the United States, the theoretical sex-averaged radiogenic excess of fatal cancers was estimated to be 140 per million and 85 per million of patients treated for proximal and distal ureteral stone, respectively. The average radiogenic risk for genetic defect associated to treatments of proximal and distal ureteral stones was found to be 2.5 and 24.4 per million of births, respectively. The radiation risk from a typical fluoroscopy guided extracorporeal shock-wave lithotripsy treatment of ureteral stones is low. Presented data may be used to determine patient effective dose from extracorporeal shock-wave lithotripsy procedures performed in any laboratory.

Dose-Response Relationship, Radiation↗

Comparison of four methods for assessing patient effective dose from radiological examinations.

Three methods of indirect effective dose estimation were reviewed and compared to a direct effective dose determination method. An anthropomorphic phantom and thermoluminescence dosimetry were used to obtain dosimetric data associated with anterior-posterior (AP) abdominal radiography, posterior-anterior (PA) chest radiography, PA head radiography, and AP heart fluoroscopy. Effective dose was determined using: (i) organ specific dose values directly determined by thermoluminescence dosimeters, (ii) data published by National Radiological Protection Board (NRPB) and entrance surface dose (ESD), (iii) NRPB data and dose area product (DAP), (iv) energy imparted derived from DAP. The effective dose values estimated from the Rando phantom measurements were 161, 32.3, and 8.4 microSv/projection for the abdomen, chest, and head radiographs, respectively. Cardiac fluoroscopy yielded an effective dose value of 111 microSv/min. The effective dose values obtained indirectly using NRPB data and DAP were in good agreement with directly assessed values in all simulated exposures (difference <8%). The effective doses using NRPB data and ESD values differed from directly assessed values by less than 15% for the radiographic exposures and 60% for heart fluoroscopy. The energy imparted method yielded 136, 31, and 6.6 microSv/projection for the abdomen, chest, and head radiographs, respectively, and 111 microSv/min for heart fluoroscopy. Indirect patient effective dose determination using the NRPB dosimetric data and the measured value of incident radiation allows for reliable patient effective dose estimates. The use of DAP rather than ESD is recommended because it yields accurate results even for complex radiologic exposures involving fluoroscopy. The value of energy imparted may be used for the accurate determination of patient effective dose, especially when specific organ dose values are not of interest. The calculation of energy imparted with the use of EAP provides a reliable starting point for estimation of effective dose from radiologic examinations for which dosimetric data are not provided by NRPB.

Abdomen↗

Normalized conceptus doses for abdominal radiographic examinations calculated using a Monte Carlo technique.

The aim of the present study was to develop a reliable method for estimating conceptus radiation doses resulting from abdominal radiographic examinations for all trimesters of pregnancy. The method is based on normalized conceptus doses estimated using Monte Carlo modeling. The Monte Carlo N-Particle (MCNP) radiation transport code was employed in the current study. The validity of the MCNP computational approach was verified by comparison with dose data obtained in anthropomorphic phantoms simulating pregnancy at the three trimesters of gestation using thermoluminescence dosimetry (TLD). The results consist of radiation doses normalized to air kerma so that conceptus dose from any technique and x-ray unit used for abdominal radiography can be easily calculated. Normalized conceptus doses are presented for the first, second, and third trimesters of gestation for various kVp and total beam filtration values. Data apply to radiographic systems equipped with high frequency or 3 phase 12 pulse generators. A very good agreement was observed between the normalized conceptus doses estimated by TLD measurements and the MCNP simulation for all periods of gestation (maximum difference 8.1%). The results of MCNP procedures were compared to published data obtained by TLD measurements. Normalized conceptus dose values agree well, with most differences being lower than 10%. The normalized doses obtained in the current study are dependent on field size. However, for small changes in the size of the x-ray field, the change in normalized doses is not considerable. Accurate estimation of conceptus doses due to abdominal conventional x-ray examinations can be made using the dose data provided in the current study.

Adult↗