Numerical estimation of heat distribution from the implantable battery system of an undulation pump LVAD.

We have been developing an implantable battery system using three series-connected lithium ion batteries having an energy capacity of 1,800 mAh to drive an undulation pump left ventricular assist device. However, the lithium ion battery undergoes an exothermic reaction during the discharge phase, and the temperature rise of the lithium ion battery is a critical issue for implantation usage. Heat generation in the lithium ion battery depends on the intensity of the discharge current, and we obtained a relationship between the heat flow from the lithium ion battery q(c)(I) and the intensity of the discharge current I as q(c)(I) = 0.63 x I (W) in in vitro experiments. The temperature distribution of the implantable battery system was estimated by means of three-dimentional finite-element method (FEM) heat transfer analysis using the heat flow function q(c)(I), and we also measured the temperature rise of the implantable battery system in in vitro experiments to conduct verification of the estimation. The maximum temperatures of the lithium ion battery and the implantable battery case were measured as 52.2 degrees C and 41.1 degrees C, respectively. The estimated result of temperature distribution of the implantable battery system agreed well with the measured results using thermography. In conclusion, FEM heat transfer analysis is promising as a tool to estimate the temperature of the implantable lithium ion battery system under any pump current without the need for animal experiments, and it is a convenient tool for optimization of heat transfer characteristics of the implantable battery system.

Electric Power Supplies↗

Estimation of early-stage malfunction using implantable artificial heart sound in animal experiments.

We have developed an automatic diagnosis system of an artificial heart in order to ensure the safety of the patient implanted with the artificial heart. The automatic diagnosis system is composed of an electro-stethoscope system, adaptive noise canceller (ANC), and artificial neural network (ANN). The ANC effectively eliminates ambient noise from the sound signal of the artificial heart detected by the electro-stethoscope, and a filtered sound signal is separated into each frequency components by fast Fourier transformation. Each frequency component of an artificial heart's acoustic signal is fed into the ANN in order to make a diagnosis of pump condition. The automatic diagnosis system was evaluated in mock circulatory tests and a long-term animal experiment using a goat implanted with an undulation pump ventricular assist device (UPVAD). In mock circulatory tests, the ANN was able to detect pump failing conditions, which were occlusion of inflow and outflow cannula and deterioration of the ball bearing. In a long-term animal experiment, after training the ANN using UPVAD's sound signal in normal condition, the diagnosis system continuously monitored UPVAD's sound signal detected by the electro-stethoscope placed on the surface of the left thoracic cavity of the goat. The UPVAD was stopped by rupture of a diaphragm in the pump on the ninth day of operation. We were able to identify initial signs of malfunction of the pump on the eighth day, while the UPVAD was able to operate normally. In conclusion, the automatic diagnosis system for malfunction of the artificial heart has enough performance to detect early stages of malfunction of the artificial heart, and it contributes to ensure the patient's safety.

Animals↗

Development of integrated electronics unit for drive and control of undulation pump-left ventricular assist device.

In this study, we have developed an implantable electronics unit (IEU) for driving an undulation pump-left ventricular assist device (UP-LVAD). The IEU consists of a pump driver, three series-connected lithium ion batteries (1800 mAh), a charger, and a transcutaneous information transmission system. These electronic subunits were encapsulated in a case (110 x approximately 80 x approximately 30 mm) made of epoxy resin. The IEU was evaluated in two animal experiments using goats implanted with the UP-LVAD. The lithium ion batteries in the IEU provided 30-min energy supply daily to the UP-LVAD. The transcutaneous information transmission system transmitted data bidirectionally between the IEU and the personal computer at the data transmission ratio of 56 kbps without any transmission error. We could obtain survival days of 27 and 28 days supporting cardiac function with the UP-LVAD system. The temperature inside the IEU case was maintained under 45 degrees C, and there was evidence of a burn on the surrounding tissue in autopsies in each experiment. Based on the results, the IEU is promising to be suitable for drive and control of an implantable UP-LVAD.

Animals↗

Influence of flow design on microcirculation in conditions of undulation pump-left ventricle assist device testing.

To study the microvessels in bulbar conjunctiva, we conducted an experiment in goat with a pneumatically driven left heart bypass pump, which was replaced with an undulation pump-left ventricle assist device for 9 days. Three flow patterns were tested: complete pulsatile, continuous, and percentage of pulsatile. We studied the morphology of arterioles and venules of the bulbar conjunctiva using photograph records. The setting up of continuous flow caused global vasoconstriction (significant in venules-P < 0.05). During the pumping in the pulsatile and percentage of pulsatile modes, no significant changes of microvessel morphology were observed. The findings described could point to some disturbances in the microcirculatory bed in conditions of continuous flow.

Animals↗

Low-frequency electrical stimulation increases muscle strength and improves blood supply in patients with chronic heart failure.

BACKGROUND: This study was designed to evaluate the effects of low-frequency electrical stimulation (LFES) on muscle strength and blood flow in patients with advanced chronic heart failure (CHF). METHODS AND RESULTS: Patients with CHF (n=15; age 56.5 +/- 5.2 years; New York Heart Association III - IV; ejection fraction 18.7 +/- 3.3%) were examined before and after 6 weeks of LFES (10 Hz) of the quadriceps and calf muscles of both legs (1 h/day, 7 days/week). Dynamometry was performed weekly to determine maximal muscle strength (F(max); N) and isokinetic peak torque (PT(max); Nm); blood flow velocity (BFV) was measured at baseline and after 6 weeks of LFES using pulsed-wave Doppler velocimetry of the right femoral artery. Six weeks of LFES significantly increased F(max) (from 224.5 +/- 96.8 N to 340.0 +/- 99.4 N; p<0.001), and also PT(max) (from 94.5 +/- 41.5 Nm to 135.3 +/- 28.8 Nm; p<0.01). BFV in the femoral artery increased after 6 weeks from 35.7 +/- 15.4 cm/s to 48.2 +/- 18.1 cm/s (p<0.05); BFV values at rest before and after 6 weeks of LFES did not differ significantly. CONCLUSIONS: LFES may improve muscle strength and blood supply, and could be recommended for the treatment of patients with severe CHF.

Biomarkers↗

Electrical stimulation of skeletal muscles. An alternative to aerobic exercise training in patients with chronic heart failure?

The aim of this study was to investigate whether electrical stimulation of skeletal muscles could represent a rehabilitation alternative for patients with chronic heart failure (CHF). Thirty patients with CHF and NYHA class II-III were randomly assigned to a rehabilitation program using either electrical stimulation of skeletal muscles or bicycle training. Patients in the first group (n = 15) had 8 weeks of home-based low-frequency electrical stimulation (LFES) applied simultaneously to the quadriceps and calf muscles of both legs (1 h/day for 7 days/week); patients in the second group (n = 15) underwent 8 weeks of 40 minute aerobic exercise (3 times a week). After the 8-week period significant increases in several functional parameters were observed in both groups: maximal VO2 uptake (LFES group: from 17.5 +/- 4.4 mL/kg/min to 18.3 +/- 4.2 mL/kg/min, P < 0.05; bicycle group: from 18.1 +/- 3.9 mL/kg/min to 19.3 +/- 4.1 mL/kg/min, P < 0.01), maximal workload (LFES group: from 84.3 +/- 15.2 W to 95.9 +/- 9.8 W, P < 0.05; bicycle group: from 91.2 +/- 13.4 W to 112.9 +/- 10.8 W, P < 0.01), distance walked in 6 minutes (LFES group: from 398 +/- 105 m to 435 +/- 112 m, P < 0.05; bicycle group: from 425 +/- 118 m to 483 +/- 120 m, P < 0.03), and exercise duration (LFES group: from 488 +/- 45 seconds to 568 +/- 120 seconds, P < 0.05; bicycle group: from 510 +/- 90 seconds to 611 +/- 112 seconds, P < 0.03). These results demonstrate that an improvement of exercise capacities can be achieved either by classical exercise training or by home-based electrical stimulation. LFES should be considered as a valuable alternative to classical exercise training in patients with CHF.

Bicycling↗

Open-loop analysis of transfer characteristics from blood pressure to heart rate using an effectively total artificial heart.

It is desirable for the dynamic behavior of the drive rate of the artificial heart to be as similar as possible to that of the recipient's heart rate (HR) before implantation. This requires a model which can simulate the behavior of HR on the basis of only the information measured with the limited number of approvable implanted sensors. This article provides a linear time series model for explaining the behavior of HR only with aortic pressure and right atrial pressure. This could be obtained from open-loop analysis using a total artificial heart, which was introduced for measuring HR in vivo and for eliminating its effect on blood pressure. The model was identified in a goat equipped with a special biventricular assist device called the effectively total artificial heart (ETAH). The ETAH was introduced to make an open loop and awake situation in the animal with almost intact autonomic nerves, which could enhance the accuracy and reliability of the identification of the model. The adequacy of the proposed model was ascertained in several data sets measured in two goats, which were different from the data set used for identification. Most of the mean estimation errors were less than 3 beats/min and auto-correlation analysis showed approvable statistical appropriateness. However, it was clarified through comparison with the 1/R control method that the proposed model has a few problems still to be solved before its future implementation as an automatic controller of the TAH.

Animals↗

Development of an implantable undulation type ventricular assist device for control of organ circulation.

It is well known that a rotary blood pump (RP) is effective as a small ventricular assist device (VAD). It might be still more effective if pulsation was available. The undulation pump (UP), which is a type of small RP, can also produce pulsation. In Japan, a development project for an implantable type UP ventricular assist device (UPVAD) is now advanced. Six universities and some companies together have been in charge of the development project for 5 years. In this study, the influence which the UP under development has on circulation in internal organs was investigated. Goats with the same weight as an average Asian person were used for the experiment. The left chest cavity was opened after resection of the fourth rib and the heart was approached. A cannula was inserted in the left ventricle from the apex. An outflow cannula was inserted into the left descending aorta. Heart muscle was excised using a newly developed puncher. The UPVAD was implanted using a left-heart bypass system. The myocardial blood flow, carotid arterial blood flow, and the kidney blood flow were recorded together with an electrocardiogram, blood pressure, and the flow rate. In these animal experiments, the blood circulation dynamic state was stabilized and sufficient support of the left heart was observed. Myocardial blood flow, carotid arterial flow, and a kidney blood flow increase resulting from UPVAD support was observed. Often the problem of multiple organ failure is important at the time of clinical application of a ventricular assist device. Assisting circulation to internal organs is important for prevention of multiple organ failure. It was concluded that the UPVAD might be useful for prevention of multiple organ failure.

Animals↗

Component engineering for an implantable system.

Component engineering is important for the development of implantable-type rotary blood pumps (RP). The authors are conducting elementary development of an implantable artificial heart. A sensor system detects information in the living body. An automatic control system performs the drive control. Energy is provided by a transcutaneous energy transmission system (TETS). Various artificial hearts are being created. Miniaturization resulting from an increase in operating frequency is planned. A vibrating flow pump (VFP) has a reduced size of pumping chamber because of the high-speed reciprocating movement. Undulation pump ventricular assist devices (UPVAD) are small, lightweight rotary pumps. VFPs are useful in the medical treatment of multiple organ failure (MOF). UPVADs are planned to be permanent-use RPs. The purposes of these two artificial hearts differ, although they have a common component. The authors are developing TETS by using amorphous fibers, making efficient power transmission possible. Control information input from a micro or nano sensor is realized. A control algorithm has been developed and baroreflex control has been successful. Artificial heart development, fully exploiting component engineering, continues.

Animals↗

Development of an electro-stethoscope system and design of an optimum filter based on tissue sound transmission for noninvasive early diagnosis of malfunction of an implanted mechanical total artificial heart.

Early diagnosis of the malfunction of a mechanical artificial heart implanted in a patient who has been discharged from hospital is very important. We have developed an electro-stethoscope system that enables the malfunction of an artificial heart to be detected from the analysis of sound signals from the artificial heart. The sound data can be transmitted to a hospital via a mobile telephone or the Internet, so that doctors can examine the condition of the artificial heart. The optimum frequency characteristics of a low-pass filter for the elimination of ambient sound through the electro-stethoscope casing were obtained by simulating sound transmission through tissue. We evaluated the usefulness of the electro-stethoscope system using a goat in which an undulation pump total artificial heart had been implanted. A frequency analysis of the sound signal provided information on the degree of degradation of each mechanical component of the artificial heart. The results of this study showed that the electro-stethoscope system is useful for the early detection of the malfunction of an artificial heart at home, and that the use of the system contributes to improvement in the quality of life of patients.

Animals↗

Preliminary study of a new type of energy transmission system for artificial hearts.

A transcutaneous energy transmission (TET) system is the most common way to power artificial hearts and ventricular assist devices. However, an external battery used with a TET system poses several problems, such as its heavy mass, small charge capacity, and long recharging time. The battery is indispensable when patients want to be ambulatory. This article proposes a new type of TET system that does not require an external battery because electrical energy is supplied remotely by using electromagnetic waves. For this system to operate, multiple transmitting antennas have to be mounted in a room or facility that has been shielded from electromagnetic waves, and a receiving antenna is attached to the patient. Electromagnetic waves transmit electrical power from the transmitting antennas to the receiving antenna. The received electrical power is sent to an implanted device through the TET system. The total power efficiency was plotted against the transmitter-receiver distance by measuring the power that was input to the transmitting antennas, and the final direct current (DC) power that was received by the receiving antenna. A 430-MHz frequency was applied in the experiments. The obtained efficiency was around 10% within a transmitter-receiver distance of 1 m when Yagi-Uda antennas were used for the transmitting antennas and two other types of antenna were used for the receiving antennas: a folded dipole with a reflector and a single loop with a reflector. The results suggested that the proposed system is worth considering. The proposed system would go a long way toward enhancing the patient's quality of life compared with the currently used conventional TET system.

Computer Simulation↗

Evaluation of pulsatile and nonpulsatile flow in microvessels of the bulbar conjunctiva in the goat with an undulation pump artificial heart.

This study has three purposes, as follows. The first is to develop a microscopic system to observe the microcirculation of animals implanted with an artificial heart. The second is to investigate the influence of flow pattern change from pulsatile to nonpulsatile on the microcirculation. The third is to study the effects of pulsatility in blood flow on endothelium-derived nitric oxide release in the microvasculature. When the flow pattern was changed from pulsatile to nonpulsatile, the velocity of erythrocytes in many capillaries dropped and remained at a low level, and the number of perfused capillaries decreased. After the flow pattern was returned to pulsatile, the velocity of erythrocytes recovered to the initial level. In many cases, the flow of nonperfused capillaries recovered to the initial level as well. Also, the pulsatile flow enhances the basal and flow-stimulated endothelium-derived nitric oxide release in microvessels.

Animals↗

Basic study to develop an electromagnetic drive method for the rotary undulation pump.

The rotary undulation pump, which is composed of a disk with a convex shape on both sides and a pump housing with one narrow side and one wide side, is a unique continuous flow pump with a new principle. The concept of the levitation drive method for this pump was proposed. The electromagnetic driver model and drive circuit were developed to examine the possibility and the difference among the delta wired, Y wired, and repulsion methods. In the repulsion method, the disk was driven by magnetic repulsion. The model could be driven with either method, and the repulsion method was demonstrated to also be possible. With either method, owing to the wide gap between the permanent magnets and coils, the output was not enough when the load was high. The efficiency was almost the same in the delta wired and Y wired methods. In the repulsion method, however, it was less than 50% of that in the other two methods. From the results, the delta wired and Y wired methods with an active control of the gap distance were considered to be better than the repulsion method, which required no active gap control.

Centrifugation↗

Progress in the control system of the undulation pump total artificial heart.

The undulation pump total artificial heart (UPTAH) is a small implantable total artificial heart. As the UPTAH generates outflow and inflow at the same time, control of the UPTAH is very difficult. Therefore suitable control methods specifically for the UPTAH should be established. Various motor control, left-right flow balance control, and physiological control methods were examined and tried for the UPTAH control in this study. The control system is divided into seven categories. It has a hierarchical structure and all control modes work at the same time. The UPTAH with the newly developed control method has been implanted into the chest cavities of 48 goats. Until now, six goats survived for more than one month, including 63 days in the longest case. The good condition of the UPTAH implanted animal could be maintained with the newly developed control scheme, consisting of the 1/R control and several other additional controls.

Animals↗

Development of a polymer bileaflet valve to realize a low-cost pulsatile blood pump.

The final goal of this study is to realize a low-cost pulsatile blood pump especially for patients with acute heart failure or postoperative low cardiac output syndrome. In support of the pump, two types of polymer bileaflet valves with different configuration of the valve seats were developed. Influence of the leaflet thickness on the hydrodynamics of the prototype was preliminarily investigated among 70 microm, 100 microm, and 150 microm. As to the valves with the thinner leaflets, buckling of the leaflets was observed, which induced a large amount of regurgitation at valve closure. However, by thickening the leaflet to 150 microm, the mean flow of the prototype and the second model could be successfully comparable to the Medtronic-Hall valve. Moreover, accelerated fatigue tests showed that reinforcement of the valve seat with the additional spokes in the second model extended the durability by four times as compared with the prototype, equivalent to an in vivo duration of over one month.

Cardiac Output, Low↗

A study on an energy supply method for a transcutaneous energy transmission system.

This study proposes a new type of a transcutaneous energy transmission system (TETS) that can supply electrical power for an implanted device without an external battery. In this system, the power is supplied from the floor to the shoes of the patients through coils that are set beneath the floor and the bottom of the shoes. If the patients wear the special shoes, they will be able to move freely on the specially designed floor without an external battery. Direct current (DC)-DC power efficiency was measured in the experiments, and the results showed that it varies with relative positions between the shoe and the floor coils. The results suggested that three-layered floor coils would enable the system to meet the demand for providing the required power anywhere on the floor without intermission. DC-DC power efficiency could be kept over 60% under the practical condition. It can then be concluded that the proposed system has a potential to provide better quality of life for the patients using a TETS.

Electromagnetic Fields↗

[Biomaterials essential to regenerative medicine].

Biomaterial is one of the most important factors to be developed in regenerative medicine. In this paper, the biomaterials essential to regenerative medicine were described. Biomaterials in regenerative medicine are classified into 5 categories; 1) Biomaterials for cell culture, 2) Biomaterials for cell inducement, 3) Biomaterials for scaffold, 4) Biomaterials for immuno-isolation, 5) Biomaterials assist to regenerative medicine. As for 1), temperature responsible gel that can take out the cultured cell sheet without use protein breakdown enzyme, is mainly introduced. Micro-photolithography to make a micro patterning for cell inducement, kinds of materials for scaffold, isolated membrane and micro capsules, carrier for cell growth factors are mentioned in 2) to 5).

Animals↗