Profile analysis and immunoglobulin E reactivity of wheat protein hydrolysates.

BACKGROUND: Wheat protein hydrolysates have been traditionally used as food additives and are now being used in cooking worldwide. There have been a few studies on the relationship between the molecular mass distribution and the immunoglobulin E (IgE) reactivity of the wheat protein hydrolysates. METHOD: We analyzed the peptide profile of commercial wheat protein hydrolysate samples from enzymatic or acid hydrolysis of wheat protein using size exclusion chromatography. We further investigated the IgE reactivity of the wheat protein hydrolysates using the inhibition ELISA method and sera of 5 patients sensitive to wheat. RESULTS: The wheat protein enzymatic hydrolysate samples showed high concentrations of peptides with molecular masses greater than 1,050 Da, whereas in contrast, the wheat protein acid hydrolysates showed extremely low concentrations of peptides with molecular masses greater than 1,050 Da. Tested wheat protein acid hydrolysates hardly inhibited the patient IgE binding ability to wheat proteins in the five patient sera. On the contrary, some tested wheat protein enzymatic hydrolysate samples inhibited the IgE binding ability to wheat proteins. CONCLUSION: These results suggested that the uptake of wheat protein enzymatic hydrolysates might still have the possibility of causing food allergic reactions in patients allergic to wheat and the processed foods containing them.

Binding Sites, Antibody↗

A detection method of CryIAc protein for identifying genetically modified rice using the lateral flow strip assay.

We examined the lateral flow strip assay for identifying unauthorized genetically modified (GM) rice. The GM rice expresses the Bacillus thuringiensis (Bt) toxin, CryIAc protein, which confers tolerance to insects. The recombinant CryIAc protein was prepared from the inclusion bodies of an E. coli. strain into which the CryIAc gene had been inserted, using gel filtration chromatography. The lateral flow strip assay for the identification of GM cotton which also expresses CryIAc protein, was applied to unpolished rice and polished rice spiked with recombinant CryIAc protein. The spiked recombinant CryIAc protein was clearly detected at the level of 0.012 microg/g in both the unpolished and polished rice. After loading of the extract on the strip, a 60 -minute stand time is necessary to clearly detect CryIAc protein. The detection limit was approximately 12 ng CryIAc protein per gram of rice. These results suggest that the lateral flow strip assay for GM cotton can be used to detect CryIAc protein expressed in GM rice.

Bacillus thuringiensis Toxins↗

[Laboratory-performance study of quantitative PCR methods to analyze an approved genetically modified maize (Mon810 Line)].

A laboratory-performance study was carried out to investigate factors affecting the reliability of the quantitative PCR method to analyze an approved genetically modified (GM) maize (Mon810 line). Test maize powdered samples were prepared as blind samples containing a high (assigned value; 5.45%) or low (assigned value; 0.35%) concentration of the Mon810 line. After confirmation of their homogeneity, they were provided to 27 laboratories participating in the collaborative study. The data were collected from all laboratories and statistically analyzed. Two laboratories, which used a Roche LightCycler (LC), reported significantly high test values. A further examination showed that the LC method is greatly affected by the equipment itself or PCR reagents, resulting in poor repeatability. On the other hand, some laboratories, which used ABI quantitative PCR equipment, reported erroneous test values. In these laboratories, the errors appeared to have been due to inadequate quality and/or yield of DNA. To identify factors affecting the test values, analysis of the measured values for the taxon-specific gene will be useful. Furthermore, the modified silica-gel membrane DNA extraction method made it possible to extract the required amounts of DNA more easily and in a shorter time than before.

DNA, Plant↗

Quantitative detection system for maize sample containing combined-trait genetically modified maize.

Various countries have established regulations that stipulate the labeling of agricultural commodities, feed, and food products that contain or are made from genetically modified (GM) material or that contain adventitious GM material in amounts that exceed certain threshold levels. While regulations in some countries refer to GM material on a weight per weight (w/w) percentage, the currently applied detection methods do not directly measure the w/w percentage of the GM material. Depending on the particular method and the sample matrix it is applied to, the conversion of analytical results to a w/w percentage is challenging or not possible. The first rapid PCR system for GM maize detection on a single kernel basis has been developed. The equipment for the grinding of individual kernels and a silica membrane-based 96-well DNA extraction kit were both significantly revised and optimized for this particular purpose, respectively. We developed a multiplex real-time PCR method for the rapid quantification of GM DNA sequences in the obtained DNA solutions. In addition, a multiplex qualitative PCR detection method allows for the simultaneous detection of different GM maize traits in each kernel and thereby for identification of individual kernels that contain a combination of two or more GM traits. Especially for grain samples that potentially contain combined-trait GM maize kernels, the proposed methods can deliver informative results in a rapid, precise, and reliable manner.

DNA, Plant↗

Gene transfection into HeLa cells by vesicles containing cationic peptide lipid.

Lipid vesicles are potentially useful as microcapsules for drug and/or gene delivery. We developed cationic lipid vesicles consisting mainly of sorbitan monooleate (Span 80) and cationic peptide lipid (CPL), and evaluated the CPL vesicles as gene transfection vectors. The optimum CPL concentration for gene transfection into HeLa cells was found to be 20 wt % of total lipid, and such CPL vesicles did not exhibit significant cytotoxicity. Co-culture of Poly-L-lysine and plasmids prior to making CPL vesicle-plasmid complexes was effective. Lipofection using LipofectAMINE was suppressed in 10% serum-supplemented medium. The transfection efficiency of 20 wt % CPL vesicles, however, was not affected by serum in the medium when plasmids were treated with poly-L-lysine.

Blood↗

[Laboratory performance study of the quantitative detection method for genetically modified soybeans (roundup ready soybeans 40-3-2)].

To investigate important factors affecting the analytical results, a laboratory-performance study was attempted for the Japanese official methods to detect genetically modified (GM) soybeans (40-3-2). Test samples containing 0, 1 and 5% GM soya powder in non-GM soya powder was prepared. A set of 3 test samples was sent to the participating laboratories along with the protocol. The data were collected from all laboratories and statistically analyzed. In the real-time PCR detection method, the average values of the GM 1% and 5% samples were both much lower than the spiked value because the laboratories using a silica-membrane DNA extraction method underestimated the GM value. On the other hand, the laboratories using other extraction methods, such as the CTAB method obtained values close to the spiked value. These results suggest that use of the silica-membrane DNA extraction method may result in underestimation of the GM content in the real-time PCR method. In the ELISA method, the average value of 5% spiked samples appears to be slightly higher than the fortified value. But, overall, it was considered that reported values were close to the spiked level.

DNA, Plant↗

[Inter-laboratory evaluation studies for development of notified ELISA methods for allergic substances (milk)].

Extracts of sausage, sauce, cookie, cereal and pasta sauce spiked with milk standard protein at a level of 5-20 ng/mL as sample solutions were analyzed in replicate in 10 laboratories. Coefficients of variation (CVs) of the three ELISA methods using a Milk Protein Casein ELISA Kit (Casein kit), a Milk Protein Beta-Lactoglobulin ELISA Kit (Beta-Lactoglobulin kit) and a FASTKIT Milk ELISA Kit (Milk ELISA kit) were mostly below 10%. Mean recoveries of the milk standard protein from the food extracts were over 40% in the three ELISA methods with a few excertions. The recoveries of milk standard protein from the sauce extract in Casein kit were improved by adjusting the extract to neutrality before the Casein kit assay. The recoveries of milk standard protein from cookie, cereal and pasta sauce were improved by the increasing the amount of antibody coated in the Milk ELISA kit. The detection limits of all the ELISA methods were 1 ng/mL in sample solutions. These results suggested that the notified ELISA methods are reliable and reproducible for the inspection of milk protein levels in extracts of sausage, sauce, cookie, cereal and pasta sauce.

Allergens↗

[Inter-laboratory evaluation studies for development of notified ELISA methods for allergic substances (wheat)].

Extracts of sausage, sauce, pasta sauce, fish paste and cereal spiked with wheat standard protein at a level of 5-20 ng/mL as sample solutions were analyzed in replicate in 10 laboratories. Coefficients of variation (CVs) of both ELISA methods using a Wheat Protein ELISA Kit (Gliadin kit) and a FASTKIT Wheat ELISA Kit (Wheat ELISA kit) were mostly below 10%. Mean recoveries of the wheat standard protein from the food extracts were over 40% in the two ELISA methods except those from cereal extract determined using the Wheat ELISA kit. Repeatability relative standard deviations of wheat standard protein in the five food extracts were in the ranges of 16-26.9% and 3.7-36.2% for the Gliadin kit and the Wheat ELISA kit, respectively. Reproducibility relative standard deviations of wheat standard protein in the five food extracts were 21.6-38.5%, 29.7-53.8% for the Gliadin kit and the Wheat ELISA kit, respectively. The recoveries of wheat standard protein from the cereal extract were improved by the increasing the amount of antibody coated on the plate in the Wheat ELISA kit. The detection limits of both ELISA methods were 1 ng/mL in sample solutions. These results suggested that the notified ELISA methods are reliable and reproducible for the inspection of wheat protein levels in extracts of sausage, sauce, pasta sauce, fish paste and cereal.

Allergens↗

[Inter-laboratory evaluation studies for establishment of notified ELISA methods for allergic substances (buckwheat)].

Inter-laboratory evaluation studies were conducted for the ELISA methods for allergic substances (buckwheat). Extracts of snack, bun and udon spiked with buckwheat standard protein at a level of 5-20 ng/mL as sample solutions were analyzed in replicate at 10 laboratories. Coefficients of variation (CVs) of the ELISA methods using a Buckwheat Protein ELISA Kit (Buckwheat kit) and a FASTKIT Buckwheat ELISA kit (Buckwheat ELISA kit) were mostly below 10%. Mean recoveries of the buckwheat standard protein from the food extracts were over 40% in the two ELISA methods. Repeatability relative standard deviations of buckwheat standard protein in three food extracts were in the ranges of 6.8-78.5% and 5.0-33.9% for the Buckwheat kit and the Buckwheat ELISA kit, respectively. Reproducibility relative standard deviations of buckwheat standard protein in three food extracts were 11.9-69.5% and 16.5-34.1% for the Buckwheat kit and the Buckwheat ELISA kit, respectively. The detection limits of both ELISA methods were 1 ng/mL in sample solutions. These results suggest that the notified ELISA methods are reliable and reproducible for the inspection of buckwheat protein levels in extracts of snack, bun and udon.

Allergens↗

[Inter-laboratory evaluation studies for establishment of notified ELISA methods for allergic substances (peanuts)].

Inter-laboratory evaluation studies were conducted for ELISA methods for allergic substances (peanuts). Extracts of biscuit, sauce, chocolate and butter spiked with peanut standard protein at a level of 5-20 ng/mL as sample solutions were analyzed in replicate in 10 laboratories. Coefficients of variation (CVs) of the ELISA methods using a Peanut Protein ELISA Kit (Peanut kit) and a FASTKIT Peanut ELISA kit (Peanut ELISA kit) were mostly below 10%. Mean recoveries of the peanut standard protein from the food extracts were over 40% in the two ELISA methods. Repeatability relative standard deviations of peanut standard protein in four food extracts were in the ranges of 15.2-49.7% and 3.0-28.3% for the Peanut kit and the Peanut ELISA kit, respectively. Reproducibility relative standard deviations of peanut standard protein in four food extracts were 23.5-44.4%, 9.6-28.4% for the Peanut kit and the Peanut ELISA kit, respectively. The detection limits of both ELISA methods were 2-2.5 ng/mL in sample solutions. These results suggested that the notified ELISA methods are reliable and reproducible for the inspection of peanut protein levels in extracts of biscuit, sauce, chocolate and butter.

Allergens↗