Hydrodynamic evaluation of kangaroo aortic valve matrices for tissue valve engineering.

We evaluated the hydrodynamic performance of kangaroo aortic valve matrices (KMs) (19, 21, and 23 mm), as potential scaffolds in tissue valve engineering using a pulsatile left heart model at low and high cardiac outputs (COs) and heart rates (HRs) of 60 and 90 beats/min. Data were measured in two samples of each type, pooled in two CO levels (2.1 +/- 0.7 and 4.2 +/- 0.6 L/min; mean +/- standard errors on the mean), and analyzed using analysis of variance with CO level, HR, and valve type as fixed factors and compared to similar porcine matrices (PMs). Transvalvular pressure gradient (DeltaP) was a function of HR (P < 0.001) and CO (P < 0.001) but not of valve type (P = 0.39). DeltaP was consistently lower in KMs but not significantly different from PMs. The effective orifice area and performance index of kangaroo matrices was statistically larger for all sizes at both COs and HRs.

Animals↗

Predicting ATS Open Pivot heart valve performance with computational fluid dynamics.

BACKGROUND AND AIM OF THE STUDY: In-vitro studies on the ATS heart valve have indicated that valve opening is less in an expanding conduit than in a straight conduit. METHODS: Bileaflet valve behavior was studied using a new computational fluid-structure interaction model. A three-dimensional model of the ATS valve was studied in two geometries, simulating the valve in a geometry with sudden expansion downstream of the valve, and in a straight conduit. Mitral and aortic flow patterns were simulated. RESULTS: The ATS valve in the expanding geometry showed opening to a maximum angle of 77.5 degrees; this was confirmed in previous clinical and in-vitro studies. The mean and maximum transvalvular Doppler pressure gradients were 1.1 and 4.3 mmHg, respectively. The maximum shear stress calculated on the leaflet was 25 Pa. Maximum opening of the valve was achieved in the straight conduit; with mean and maximum pressure gradients of 2.1 and 4.6 mmHg, respectively. The maximum shear stress calculated on the leaflet was 35 Pa. CONCLUSION: The results of this numerical study confirmed that valve hemodynamics and leaflet motion were dependent on the geometrical conditions of the valve: the presence of a diverging flow influenced the maximum opening angle of the valve leaflets. This model could be used to predict pressure gradients, effective orifice area, performance index and shear stress loading of mechanical heart valves, and in future will serve as a major research tool to characterize the hemodynamics of existing and new mechanical heart valves.

Aortic Valve↗

Design of a new pulsatile bioreactor for tissue engineered aortic heart valve formation.

Evidence has been gathered that biomechanical factors have a significant impact on cell differentiation and behavior in in vitro cell cultures. The aim of this bioreactor is to create a physiological environment in which tissue engineered (TE) aortic valves seeded with human cells can be cultivated during a period of several days. The bioreactor consists of 2 major parts: the left ventricle (LV) and the afterload consisting of a compliance, representing the elastic function of the large arteries, and in series a resistance, mimicking the arterioles and capillaries. The TE aortic valve is placed between the LV and the compliance. With controllable resistance, compliance, stroke volume and frequency, and hydrodynamic conditions can be changed over a wide physiological range. This study resulted in a prototype of a compact pulsatile flow system for the creation of TE aortic valves. In addition a biocompatibility study of the used materials is performed.

Aortic Valve↗

Mock loop testing of On-x prosthetic mitral valve with Doppler echocardiography.

Previous in vitro testing (mainly in aortic position) and clinical experience (often based on Doppler echocardiographic observations) demonstrated an excellent hemodynamic behavior of the On-X valve. However, integrative studies including simultaneous hemodynamic pressure and flow measurements and Doppler echocardiography are lacking. Using our computer-controlled mock loop system, two samples of the Mitral 27/29 and one sample of the Conform-X Mitral 25/33 are tested in mitral position. Data include transvalvular pressure gradient and flow as well as transthoracic Doppler echocardiography. The valves are tested under three pressure conditions (ventricular systolic pressure of 100, 130, and 160 mm Hg) at three different heart rates (60, 100, and 140 beats/min). In addition, ventricular pressure conditions simulating fibrillation are imposed. Both valve types show similar hydrodynamic characteristics and have an effective orifice area of 2.1 cm2 and a performance index of 0.56 for a cardiac output of 3.5 L/min. Regurgitant volumes remain below 6 ml.