PubMed Health⌕ Search

Biomedical subjects

Kristy K Brock

Publications and source records attributed to Kristy K Brock.

11 recordsLinked to original sources

A magnetic resonance imaging study of prostate deformation relative to implanted gold fiducial markers.

PURPOSE: To describe prostate deformation during radiotherapy and determine the margins required to account for prostate deformation after setup to intraprostatic fiducial markers (FM). METHODS AND MATERIALS: Twenty-five patients with T1c-T2c prostate cancer had three gold FMs implanted. The patients presented with a full bladder and empty rectum for two axial magnetic resonance imaging (MRI) scans using a gradient recalled echo (GRE) sequence capable of imaging the FMs. The MRIs were done at the time of radiotherapy (RT) planning and a randomly assigned fraction. A single observer contoured the prostate surfaces. They were entered into a finite element model and aligned using the centroid of the three FMs. RESULTS: During RT, the prostate volume decreased by 0.5%/fraction (p = 0.03) and the FMs in-migrated by 0.05 mm/fraction (p < 0.05). Prostate deformation was unrelated to differential bladder and bowel filling, but was related to a transurethral resection of the prostate (TURP) (p = 0.003). The standard deviation for systematic uncertainty of prostate surface contouring was 0.8 mm and for FM centroid localization was 0.4 mm. The standard deviation of random interfraction prostate deformation was 1.5 mm and for FM centroid variability was 1.1 mm. These uncertainties from prostate deformation can be incorporated into a margin recipe to determine the total margins required for RT. CONCLUSIONS: During RT, the prostate exhibited: volume decrease, deformation, and in-migration of FMs. Patients with TURPs were prone to prostate deformation.

Aged↗

Prospective comparison of computed tomography and magnetic resonance imaging for liver cancer delineation using deformable image registration.

PURPOSE: The aim of this study was to compare magnetic resonance imaging (MRI) with computed tomography (CT) for liver cancer tumor definition for high-precision radiotherapy planning. METHODS AND MATERIALS: Diagnostic quality MRI scans and triphasic CT scans, with the liver immobilized in exhale, were obtained at the time of radiation planning for 26 patients with unresectable liver metastases (n = 8), hepatocellular carcinoma (n = 10), and cholangiocarcinoma (n = 8). On the CT and MRI series best demonstrating the tumor, the liver and gross tumor volumes (GTVs) were contoured, and intrahepatic anatomic reference points were identified. Deformable registration was used to register the liver from the CT with that from the MRI. RESULTS: A difference in the number of tumor foci was seen on CT vs. MRI in 5 patients with hepatocellular carcinoma: MRI showed more foci in 3 patients, CT in 2. After deformable registration of the livers, the population median of the average distance between the CT tumor surface and MRI tumor surface was 3.7 mm (2.2-21.3 mm). The median percentage of tumor surface area that differed by > or = 5 mm was 26% (1-86%). Median percentage concordance volumes were 81% (77-86%) in metastases, 77% (60-88%) in hepatocellular carcinoma and 64% (25-85%) in cholangiocarcinoma. CONCLUSION: Differences between MRI-defined liver cancer GTVs and CT-defined GTVs can be substantial and are more common in primary liver cancer.

Carcinoma, Hepatocellular↗

Assessment of residual error in liver position using kV cone-beam computed tomography for liver cancer high-precision radiation therapy.

PURPOSE: To evaluate the residual error in liver position using breath-hold kilovoltage (kV) cone-beam computed tomography (CT) following on-line orthogonal megavoltage (MV) image-guided breath-hold liver cancer conformal radiotherapy. METHODS AND MATERIALS: Thirteen patients with liver cancer treated with 6-fraction breath-hold conformal radiotherapy were investigated. Before each fraction, orthogonal MV images were obtained during exhale breath-hold, with repositioning for offsets>3 mm, using the diaphragm for cranio-caudal (CC) alignment and vertebral bodies for medial-lateral (ML) and anterior posterior (AP) alignment. After repositioning, repeat orthogonal MV images, orthogonal kV fluoroscopic movies, and kV cone-beam CTs were obtained in exhale breath-hold. The cone-beam CT livers were registered to the planning CT liver to obtain the residual setup error in liver position. RESULTS: After repositioning, 78 orthogonal MV image pairs, 61 orthogonal kV image pairs, and 72 kV cone-beam CT scans were obtained. Population random setup errors (sigma) in liver position were 2.7 mm (CC), 2.3 mm (ML), and 3.0 mm (AP), and systematic errors (Sigma) were 1.1 mm, 1.9 mm, and 1.3 mm in the superior, medial, and posterior directions. Liver offsets>5 mm were observed in 33% of cases; offsets>10 mm and liver deformation>5 mm were observed in a minority of patients. CONCLUSIONS: Liver position after radiation therapy guided with MV orthogonal imaging was within 5 mm of planned position in the majority of patients. kV cone-beam CT image guidance should improve accuracy with reduced dose compared with orthogonal MV image guidance for liver cancer radiation therapy.

Carcinoma, Hepatocellular↗

Reproducibility of liver position using active breathing coordinator for liver cancer radiotherapy.

PURPOSE: To measure the intrabreath-hold liver motion and the intrafraction and interfraction reproducibility of liver position relative to vertebral bodies using an active breathing coordinator (ABC) in patients with unresectable liver cancer treated with hypofractionated stereotactic body radiation therapy (SBRT). METHODS: Tolerability of ABC and organ motion during ABC was assessed using kV fluoroscopy in 34 patients. For patients treated with ABC, repeat breath-hold CT scans in the ABC breath-hold position were acquired at simulation to estimate the volumetric intrafraction reproducibility of the liver relative to the vertebral bodies. In addition, preceding each radiation therapy fraction, with the liver immobilized using ABC, repeat anteroposterior (AP) megavoltage verification images were obtained. Off-line alignments were completed to determine intrafraction reproducibility (from repeat images obtained before one treatment) and interfraction reproducibility (from comparisons of the final image for each fraction with the AP) of diaphragm position relative to vertebral bodies. For each image set, the vertebral bodies were aligned, and the resultant craniocaudal (CC) offset in diaphragm position was measured. Liver position during ABC was also evaluated from kV fluoroscopy acquired at the time of simulation, kV fluoroscopy at the time of treatment, and from MV beam's-eye view movie loops acquired during treatment. RESULTS: Twenty-one of 34 patients were screened to be suitable for ABC. The average free breathing range of these patients was 13 mm (range, 5-1 mm). Fluoroscopy revealed that the average maximal diaphragm motion during ABC breath-hold was 1.4 mm (range, 0-3.4 mm). The MV treatment movie loops confirmed diaphragm stability during treatment. For a measure of intrafraction reproducibility, an analysis of 36 repeat ABC computed tomography (CT) scans in 14 patients was conducted. The average mean difference in the liver surface position was -0.9 mm, -0.5 mm, and 0.2 mm in the CC, AP, and medial-lateral (ML) directions, with a standard deviation of 1.5 mm, 1.5 mm, and 1.5 mm, respectively. Ninety-five percent of the liver surface had an absolute differences in position between repeat ABC CT scans of less than 4.1 mm, 3.3 mm, and 3.3 mm in the CC, AP, and ML directions, respectively. Analysis of 257 MV AP images from patients treated using ABC revealed an average intrafraction CC reproducibility (sigma) of diaphragm relative to vertebral bodies of 1.5 mm (range, 0.6-3.9 mm). The average interfraction CC reproducibility (sigma) was 3.4 mm (range, 1.5-7.9 mm), indicating less day-to-day reproducibility of diaphragm position relative to vertebral bodies. The average absolute intra and interfraction CC offset in diaphragm position relative to vertebral bodies was 1.7 and 3.7 mm, respectively, with 86% of intrafraction and 54% of interfraction absolute offsets 3.0 mm or less. CONCLUSIONS: Intrafraction reproducibility of liver position using ABC is good in the majority of screened patients. However, interfraction reproducibility is worse, suggesting a need for image guidance.

Adult↗

Feasibility of a novel deformable image registration technique to facilitate classification, targeting, and monitoring of tumor and normal tissue.

PURPOSE: To investigate the feasibility of a biomechanical-based deformable image registration technique for the integration of multimodality imaging, image guided treatment, and response monitoring. METHODS AND MATERIALS: A multiorgan deformable image registration technique based on finite element modeling (FEM) and surface projection alignment of selected regions of interest with biomechanical material and interface models has been developed. FEM also provides an inherent method for direct tracking specified regions through treatment and follow-up. RESULTS: The technique was demonstrated on 5 liver cancer patients. Differences of up to 1 cm of motion were seen between the diaphragm and the tumor center of mass after deformable image registration of exhale and inhale CT scans. Spatial differences of 5 mm or more were observed for up to 86% of the surface of the defined tumor after deformable image registration of the computed tomography (CT) and magnetic resonance images. Up to 6.8 mm of motion was observed for the tumor after deformable image registration of the CT and cone-beam CT scan after rigid registration of the liver. Deformable registration of the CT to the follow-up CT allowed a more accurate assessment of tumor response. CONCLUSIONS: This biomechanical-based deformable image registration technique incorporates classification, targeting, and monitoring of tumor and normal tissue using one methodology.

Biomechanical Phenomena↗

Evaluating the influence of setup uncertainties on treatment planning for focal liver tumors.

PURPOSE: A mechanism has been developed to evaluate the influence of random setup variations on dose during treatment planning. The information available for studying these factors shifts from population-based models toward patient-specific data as treatment progresses and setup measurements for an individual patient become available. This study evaluates the influence of population as well as patient-specific setup distributions on treatment plans for focal liver tumors. METHODS AND MATERIALS: Eight patients with focal liver tumors were treated on a protocol that involved online setup measurement and adjustment, as well as ventilatory immobilization. Summary statistics from these three-dimensional conformal treatments yielded individual and population distributions of position at initial setup for each fraction. A convolution model for evaluation of the influence of random setup variation on calculated dose distributions has been previously described and investigated for application to focal liver radiotherapy by our department. Individual patient doses based on initial setup positions were calculated by convolving the calculated dose distribution with an anisotropic probability distribution function representing the individual patient's random variations. A separate convolution using population-averaged random variations was performed. Individual beam apertures were then adjusted to provide plans that ensured proper dose to the clinical target volume following convolution with population distributions, as well as individual patient position uncertainty models. RESULTS: Individual patient setup distributions for the course of treatment had random setup variations (sigma) that ranged from 2.5 to 5.7 mm (left-right), 2.1 to 8.3 mm (anterior-posterior), and 4.1 to 10.8 mm (cranial-caudal). The population random components were 4.2 mm (left-right), 4.1 mm (anterior-posterior), and 7.0 mm (cranial-caudal) at initial setup. The initial static planned dose distribution overestimated the volume of liver irradiated to high doses, because inclusion of setup uncertainties generally blurred the resulting doses, shifting the higher-dose region of normal liver dose-volume histograms to lower doses. Furthermore, the population-based dose convolution tended to predict a higher risk of radiation damage to the liver (based on an in-house parameterization of the Lyman normal tissue complication probability model) than the individual patient calculations. For an individual plan, application of different individual random variations yielded change in effective volume differences with a 3% range. Plan adjustment to account for random setup variations generally resulted in a lower change in effective volume than initial planning using a planning target volume followed by calculation of delivered dose based on random offsets. CONCLUSION: This study hints at the factors that most strongly influence planning of liver treatments taking into account geometric variations. Given a setup verification methodology that rapidly reduces systematic offsets, the importance of realistic incorporation of geometric variations as an initial step in treatment planning, as well as possible plan refinement, is demonstrated.

Feasibility Studies↗

Accuracy of daily image guidance for hypofractionated liver radiotherapy with active breathing control.

PURPOSE: A six-fraction, high-precision radiotherapy protocol for unresectable liver cancer has been developed in which active breathing control (ABC) is used to immobilize the liver and daily megavoltage (MV) imaging and repositioning is used to decrease geometric uncertainties. We report the accuracy of setup in the first 20 patients consecutively treated using this approach. METHODS AND MATERIALS: After setup using conventional skin marks and lasers, orthogonal MV images were acquired with the liver immobilized using ABC. The images were aligned to reference digitally reconstructed radiographs using the diaphragm for craniocaudal (CC) alignment and the vertebral bodies for anterior-posterior (AP) and mediolateral (ML) alignment. Adjustments were made for positioning errors >3 mm. Verification imaging was repeated after repositioning to assess for residual positioning error. Offline image matching was conducted to determine the setup accuracy using this approach compared with the initial setup error before repositioning. Real-time beam's-eye-view MV movies containing an air-diaphragm interface were also evaluated. RESULTS: A total of 405 images were evaluated from 20 patients. Repositioning occurred in 109 of 120 fractions because of offsets >3 mm. Three to eight beam angles, with up to four segments per field, were used for each isocenter. Breath holds of up to 27 s were used for imaging and treatment. The average time from the initial verification image to the last treatment beam was 21 min. Image guidance and repositioning reduced the population random setup errors (sigma) from 6.5 mm (CC), 4.2 mm (ML), and 4.7 mm (AP) to 2.5 mm (CC), 2.8 mm (ML), and 2.9 mm (AP). The average individual random setup errors (sigma) were reduced from 4.5 mm (CC), 3.2 mm (AP), and 2.5 mm (ML) to 2.2 mm (CC), 2.0 mm (AP), and 2.0 mm (ML). The standard deviation of the distribution of systematic deviations (Sigma) was also reduced from 5.1 mm (CC), 3.4 mm (ML), and 3.1 mm (AP) to 1.4 mm (CC), 2.0 mm (ML), and 1.9 mm (AP) with image guidance and repositioning. The average absolute systematic errors were reduced from 4.1 mm (CC), 2.4 mm (AP), and 3.1 (ML) to 1.1 mm (CC), 1.3 mm (AP), and 1.6 mm (ML). Analysis of 52 real-time beam's-eye-view MV movies revealed an average absolute CC offset in diaphragm position of 1.9 mm. CONCLUSION: Image guidance with orthogonal MV imaging and ABC for stereotactic body radiotherapy for liver cancer is feasible, improving setup accuracy compared with ABC without daily imaging and repositioning.

Carcinoma, Hepatocellular↗

Adaptive registration using local information measures.

Rapidly advancing registration methods increasingly employ warping transforms. High degrees of freedom (DOF) warpings can be specified by manually placing control points or instantiating a regular, dense grid of control points everywhere. The former approach is laborious and prone to operator bias, whereas the latter is computationally expensive. We propose to improve upon the latter approach by adaptively placing control points where they are needed. Local estimates of mutual information (MI) and entropy are used to identify local regions requiring additional DOF.

Abdomen↗

Daily prostate targeting using implanted radiopaque markers.

PURPOSE: A system has been implemented for daily localization of the prostate through radiographic localization of implanted markers. This report summarizes an initial trial to establish the accuracy of patient setup via this system. METHODS AND MATERIALS: Before radiotherapy, three radiopaque markers are implanted in the prostate periphery. Reference positions are established from CT data. Before treatment, orthogonal radiographs are acquired. Projected marker positions are extracted semiautomatically from the radiographs and aligned to the reference positions. Computer-controlled couch adjustment is performed, followed by acquisition of a second pair of radiographs to verify prostate position. Ten patients (6 prone, 4 supine) participated in a trial of daily positioning. RESULTS: Three hundred seventy-four fractions were treated using this system. Treatment times were on the order of 30 minutes. Initial prostate position errors (sigma) ranged from 3.1 to 5.8 mm left-right, 4.0 to 10.1 mm anterior-posterior, and 2.6 to 9.0 mm inferior-superior in prone patients. Initial position was more reproducible in supine patients, with errors of 2.8 to 5.0 mm left-right, 1.9 to 3.0 mm anterior-posterior, and 2.6 to 5.3 mm inferior-superior. After prostate localization and adjustment, the position errors were reduced to 1.3 to 3.5 mm left-right, 1.7 to 4.2 mm anterior-posterior, and 1.6 to 4.0 mm inferior-superior in prone patients, and 1.2 to 1.8 mm left-right, 0.9 to 1.8 mm anterior-posterior, and 0.8 to 1.5 mm inferior-superior in supine patients. CONCLUSIONS: Daily targeting of the prostate has been shown to be technically feasible. The implemented system provides the ability to significantly reduce treatment margins for most patients with cancer confined to the prostate. The differences in final position accuracy between prone and supine patients suggest variations in intratreatment prostate movement related to mechanisms of patient positioning.

Dose Fractionation, Radiation↗

Daily targeting of intrahepatic tumors for radiotherapy.

INTRODUCTION: A system has been developed for daily targeting of intrahepatic tumors using a combination of ventilatory immobilization, in-room diagnostic imaging, and on-line setup adjustment. By reducing geometric position uncertainty, as well as organ movement, this system permits reduction of margins and thus potentially higher treatment doses. This paper reports our initial experience treating 8 patients with focal liver tumors using this system. METHODS AND MATERIALS: The system includes diagnostic X-ray tubes mounted on the wall and ceiling of a treatment room, an active matrix flat panel imager, in-room control for image acquisition and setup adjustment, and a ventilatory immobilization system via active breathing control (ABC). Eight patients participated in the study, two using an early prototype ABC unit, and the remaining six with a commercial ABC system and improved setup measurement tools. Treatment margins were reduced, and dose consequently increased because of increased confidence in target position under this protocol. After daily setup via skin marks, orthogonal radiographs were acquired at suspended ventilation. The images were aligned to the CT model using the diaphragm for inferior-superior (IS) alignment, and the skeleton for left-right (LR) and anterior-posterior (AP) alignment. Adjustments were made for positioning errors greater than a threshold (3 or 5 mm). After treatment, retrospective analysis determined the final setup accuracy, as well as the error in initial setup measurement performed before setup adjustment. RESULTS: Two hundred sixty-two treatment fractions were delivered on eight patients, with 171 treatments requiring repositioning. Typical treatment times were 25-30 min. Patients were able to tolerate ABC throughout the course of treatment. Breath holds up to 35 s long were used for treatment. The use of on-line imaging and setup adjustment reduced setup errors (sigma) from 4.0 mm (LR), 6.7 mm (IS), and 3.8 mm (AP) to 2.1 mm (LR), 3.5 mm (IS), and 2.3 mm (AP). Prescribed doses were increased using this system by an average of 5 Gy. CONCLUSIONS: Daily targeting of intrahepatic targets has been demonstrated to be feasible. The potential for reduction in treatment margin and consequential safe dose escalation has been demonstrated, while maintaining reasonable treatment delivery times.

Dose Fractionation, Radiation↗

A comparison of computer-controlled versus manual on-line patient setup adjustment.

A study was performed to determine the relative advantage of computer-controlled couch movement versus manual repositioning to correct patient setup error measured using an electronic portal imaging device (EPID). Twenty-eight on-line setup adjustment trials of anterior-posterior (AP) pelvic projections were evaluated, with 13 setups corrected by automated couch movement determined by direct feedback from the EPID image alignment tool and 15 setups manually corrected based on the transformation displayed from the same tool. The speed of setup adjustment and accuracy of corrected setup were determined. Computer controlled setup adjustment was determined to be faster (25.4 s versus 101.9 s) and slightly more accurate (1.8 mm versus 2.5 mm error in adjusted setup) than manual correction.

Humans↗