PubMed Health⌕ Search

Biomedical subjects

Kwok Tam

Publications and source records attributed to Kwok Tam.

2 recordsLinked to original sources

An approximate short scan helical FDK cone beam algorithm based on nutating curved surfaces satisfying the Tuy's condition.

Traditionally, short scan helical FDK algorithms have been implemented based on horizontal transaxial slices. However, not every point on the horizontal transaxial slice satisfies Tuy's condition for the corresponding (pi+fan angle) segment of helix, which means that some points on the horizontal slices are incompletely sampled and are impossible to be exactly reconstructed. In this paper, we propose and implement an improved but still approximate short scan helical cone beam FDK algorithm based on nutating curved surfaces satisfying the Tuy's condition. This surface is defined by averaging PI surfaces emanating the initial and final source points of a (pi+fan angle) segment of helix. One of the key characteristics of the surface is that every point on it satisfies the Tuy's condition for the corresponding (pi+fan angle) segment of helix, which means that we can potentially reconstruct every point on the surface exactly. This difference makes the proposed algorithm deliver a better-reconstructed image quality while requiring a smaller detector area than that of traditional FDK methods based on horizontal transaxial slices. Another characteristic of the proposed surface is that every point within the helix belongs to one and only one such surface. Therefore, the location of the short scan segment for the reconstruction of a point in Cartesian coordinate could be precalculated and stored in a look-up table. This enables us to perform reconstruction directly on rectangular grids. We compare the performance of the improved FDK algorithm with that of a quasi-exact algorithm based on data combination technique. The simulation results show that the reconstructed image quality of these two methods is similar.

Algorithms↗

A simple derivation and analysis of a helical cone beam tomographic algorithm for long object imaging via a novel definition of region of interest.

We derive and analyse a simple algorithm first proposed by Kudo et al (2001 Proc. 2001 Meeting on Fully 3D Image Reconstruction in Radiology and Nuclear Medicine (Pacific Grove, CA) pp 7-10) for long object imaging from truncated helical cone beam data via a novel definition of region of interest (ROI). Our approach is based on the theory of short object imaging by Kudo et al (1998 Phys. Med. Biol. 43 2885-909). One of the key findings in their work is that filtering of the truncated projection can be divided into two parts: one, finite in the axial direction, results from ramp filtering the data within the Tam window. The other, infinite in the z direction, results from unbounded filtering of ray sums over PI lines only. We show that for an ROI defined by PI lines emanating from the initial and final source positions on a helical segment, the boundary data which would otherwise contaminate the reconstruction of the ROI can be completely excluded. This novel definition of the ROI leads to a simple algorithm for long object imaging. The overscan of the algorithm is analytically calculated and it is the same as that of the zero boundary method. The reconstructed ROI can be divided into two regions: one is minimally contaminated by the portion outside the ROI, while the other is reconstructed free of contamination. We validate the algorithm with a 3D Shepp-Logan phantom and a disc phantom.

Algorithms↗