PubMed Health⌕ Search

Biomedical subjects

Kyle W Hollman

Publications and source records attributed to Kyle W Hollman.

5 recordsLinked to original sources

Mapping age-related elasticity changes in porcine lenses using bubble-based acoustic radiation force.

Bubble-based acoustic radiation force aims to measure highly localized tissue viscoelastic properties. In the current investigation, acoustic radiation force was applied to laser-induced bubbles to measure age-related changes in the spatial distribution of elastic properties within in vitro porcine lenses. A potential in vivo technique to map lens elasticity is crucial to understanding the onset of presbyopia and develop new treatment options. Bubble-based acoustic radiation force was investigated as a technique to measure the spatial elasticity distribution of the lens in its natural state without disrupting the lens capsule. Laser-induced optical breakdown (LIOB) generated microbubbles in a straight line across the equatorial plane of explanted porcine lenses with 1mm lateral spacing. Optical breakdown occurs when sufficiently high threshold fluence is attained at the focus of femtosecond pulsed lasers, inducing plasma formation and bubble generation. A two-element confocal ultrasonic transducer applied 6.5 ms acoustic radiation force-chirp bursts with the 1.5 MHz outer element while monitoring bubble position within the lens using pulse-echoes with the 7.44 MHz inner element. A cross-correlation method was used to measure bubble displacements and determine exponential time constants of the temporal responses. Maximum bubble displacements are inversely proportional to the local Young's modulus, while time constants are indicative of viscoelastic properties. The apparent spatial elasticity distributions in 41 porcine lenses, ranging from 4 months to 5 years in age, were measured using bubble-based acoustic radiation force. Bubble displacements decrease closer to the porcine lens center, suggesting that the nucleus is stiffer than the cortex. Bubble displacements decrease with increasing lens age, suggesting that porcine lenses become stiffer with age. Bubble-based acoustic radiation force may be well-suited as a potential in vivo technique to spatially map elastic properties of the lens and guide therapeutic procedures aimed at restoring accommodation.

Aging↗

Bubble-based acoustic radiation force elasticity imaging.

Acoustic radiation force is applied to bubbles generated by laser-induced optical breakdown (LIOB) to study viscoelastic properties of the surrounding medium. In this investigation, femtosecond laser pulses are focused in the volume of gelatin phantoms of different concentrations to form bubbles. A two-element confocal ultrasonic transducer generates acoustic radiation force on individual bubbles while monitoring their displacement within a viscoelastic medium. Tone burst pushes of varying duration have been applied by the outer element at 1.5 MHz. The inner element receives pulse-echo recordings at 7.44 MHz before, during, and after the excitation bursts, and crosscorrelation processing is performed offline to monitor bubble position. Maximum bubble displacements are inversely related to the Young's moduli for different gel phantoms, with a maximum bubble displacement of over 200 microm in a gel phantom with a Young's modulus of 1.7 kPa. Bubble displacements scale with the applied acoustic radiation force and displacements can be normalized to correct for differences in bubble size. Exponential time constants for bubble displacement curves are independent of bubble radius and follow a decreasing trend with the Young's modulus of the surrounding medium. These results demonstrate the potential for bubble-based acoustic radiation force methods to measure tissue viscoelastic properties.

Computer Simulation↗

Acoustic detection of controlled laser-induced microbubble creation in gelatin.

A high-frequency (85 MHz) acoustic technique is used to identify system parameters for controlled laser-induced microbubble creation inside tissue-mimicking, gelatin phantoms. Microbubbles are generated at the focus of an ultrafast 793-nm laser source and simultaneously monitored through ultrasonic pulse-echo recordings. Displayed in wavefield form, these recordings illustrate microbubble creation, and integrated backscatter plots provide specifics about microbubble characteristics and dissolution behavior. By varying laser parameters, including pulse fluence (or pulse energy flux, J/cm2), total number of pulses delivered, and the period between pulses, the size, lifetime, and dissolution dynamics of laser-induced microbubbles may be independently controlled. Pulse fluence is the main size-controlling parameter, whereas both increases in pulse fluence and pulse number can lengthen microbubble lifetime from tens to hundreds of milliseconds. In short, a microbubble of particular lifetime does not necessarily have to be of a particular size. Microbubble behavior, furthermore, is independent of pulse periods below a fluence-dependent threshold value, but it exhibits stochastic behavior if pulse repetition is too slow. These results demonstrate that laser pulse fluence, number, and period may be varied to deposit energy in a specific temporal manner, creating and stabilizing microbubbles with particular characteristics and, therefore, potential uses in sensitive acoustic detection and manipulation schemes.

Acoustics↗

Trapping cavitation bubbles with a self-focused laser beam.

We observed that laser-induced cavitation bubbles in water can be trapped in a self-focused laser beam. Both optical imaging and acoustic detection have been utilized to confirm bubble trapping. Transverse and longitudinal trapping forces were measured to be as large as 87 and 11 pN, respectively. This result is contrary to conventional wisdom, since the mechanism of trapping in conventional optical tweezers implies that a low-index particle (a bubble being the limiting case) should be antitrapped.

Equipment Design↗

Strain imaging of corneal tissue with an ultrasound elasticity microscope.

PURPOSE: We hypothesize that high-resolution elasticity measurements can guide corrective refractive surgery of the cornea. Elasticity measurements would improve surgical outcomes by adding biomechanical information not used in existing clinical nomograms. As an initial investigation, we determined the usefulness and evaluated the ability of our ultrasound elasticity microscope by measuring strain ex vivo in an intact porcine eye globe. METHODS: Strain was predicted with a finite element model guided by direct mechanical measurements of corneal elasticity. Next, a porcine cornea was deformed with a slitted plate while being imaged with ultrasound. For high spatial resolution, the ultrasound elasticity microscope uses a 50 MHz transducer with a 1.4 f/number. It produces high-quality conventional ultrasonic B-scans over large thicknesses by confocal processing. Strain was calculated from tracking speckle in these images after deformation. This technique is compatible with in vivo measurements. RESULTS: Compressional and expansional deformations were the same order of magnitude from -3.5% to as great as +3.5%. Strain imaging indicated the stroma expanded into the slit of the deformation plate while Bowman's layer compressed. This bipolar variation within a specimen is unusual. Within the stroma, a variation of strain with depth was measured suggesting a distribution of elasticity. Results compared favorably with the finite element model. CONCLUSION: An ultrasound elasticity microscope can produce high-resolution strain images throughout the corneal depth. Various layers with different elastic properties appeared as different strains in the images.

Animals↗