PubMed Health⌕ Search

Biomedical subjects

Kyriaki Theodorou

Publications and source records attributed to Kyriaki Theodorou.

6 recordsLinked to original sources

Clinical validation of the LKB model and parameter sets for predicting radiation-induced pneumonitis from breast cancer radiotherapy.

The choice of the appropriate model and parameter set in determining the relation between the incidence of radiation pneumonitis and dose distribution in the lung is of great importance, especially in the case of breast radiotherapy where the observed incidence is fairly low. From our previous study based on 150 breast cancer patients, where the fits of dose-volume models to clinical data were estimated (Tsougos et al 2005 Evaluation of dose-response models and parameters predicting radiation induced pneumonitis using clinical data from breast cancer radiotherapy Phys. Med. Biol. 50 3535-54), one could get the impression that the relative seriality is significantly better than the LKB NTCP model. However, the estimation of the different NTCP models was based on their goodness-of-fit on clinical data, using various sets of published parameters from other groups, and this fact may provisionally justify the results. Hence, we sought to investigate further the LKB model, by applying different published parameter sets for the very same group of patients, in order to be able to compare the results. It was shown that, depending on the parameter set applied, the LKB model is able to predict the incidence of radiation pneumonitis with acceptable accuracy, especially when implemented on a sub-group of patients (120) receiving [see text]|EUD higher than 8 Gy. In conclusion, the goodness-of-fit of a certain radiobiological model on a given clinical case is closely related to the selection of the proper scoring criteria and parameter set as well as to the compatibility of the clinical case from which the data were derived.

Abnormalities, Radiation-Induced↗

Correlation between radiation-induced telomerase activity and human telomerase reverse transcriptase mRNA expression in HeLa cells.

PURPOSE: To quantify and correlate human telomerase reverse transcriptase (hTERT) mRNA expression with telomerase activity (TA) after ionizing irradiation of HeLa cells. MATERIALS AND METHODS: TA and hTERT mRNA expression were evaluated, at 24-h intervals, in HeLa cells cultured for up to 144 h, before and after treatment with increasing doses of 6 MV photon ionizing radiation (5 - 20 Gy), using the telomeric repeat amplification protocol (TRAP) assay and real-time reverse transcriptase polymerase chain reaction (RT-PCR), respectively. Cell viability was determined using the 3-(4,5-dimethylthiazole-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) assay. A prototype phantom was constructed for accurate irradiation of HeLa cells. RESULTS: Treated cells showed a decrease in viability with increasing radiation dose, and a correlation was observed with post-treatment period. TA and hTERT mRNA expression of HeLa cells increased for the first 24 h after irradiation. The maximal increases were approximately two times the un-irradiated cell levels at 24 h post-irradiation, followed by a decrease and a return to the control levels 72 h post-irradiation. The time-course of telomerase activation after 24 h, differed among radiation doses. A dose-dependent G2/M arrest was observed 24 h post-irradiation, along with an increase in polyploidy 48 h post-irradiation and afterwards. CONCLUSION: A correlation between TA and hTERT mRNA expression and a radiation induced cell cycle dependent modification of hTERT mRNA expression was established for the first 24 h post-irradiation.

Cell Survival↗

Evaluation of dose-response models and parameters predicting radiation induced pneumonitis using clinical data from breast cancer radiotherapy.

The purpose of this work is to evaluate the predictive strength of the relative seriality, parallel and LKB normal tissue complication probability (NTCP) models regarding the incidence of radiation pneumonitis, in a large group of patients following breast cancer radiotherapy, and furthermore, to illustrate statistical methods for examining whether certain published radiobiological parameters are compatible with a clinical treatment methodology and patient group characteristics. The study is based on 150 consecutive patients who received radiation therapy for breast cancer. For each patient, the 3D dose distribution delivered to lung and the clinical treatment outcome were available. Clinical symptoms and radiological findings, along with a patient questionnaire, were used to assess the manifestation of radiation-induced complications. Using this material, different methods of estimating the likelihood of radiation effects were evaluated. This was attempted by analysing patient data based on their full dose distributions and associating the calculated complication rates with the clinical follow-up records. Additionally, the need for an update of the criteria that are being used in the current clinical practice was also examined. The patient material was selected without any conscious bias regarding the radiotherapy treatment technique used. The treatment data of each patient were applied to the relative seriality, LKB and parallel NTCP models, using published parameter sets. Of the 150 patients, 15 experienced radiation-induced pneumonitis (grade 2) according to the radiation pneumonitis scoring criteria used. Of the NTCP models examined, the relative seriality model was able to predict the incidence of radiation pneumonitis with acceptable accuracy, although radiation pneumonitis was developed by only a few patients. In the case of modern breast radiotherapy, radiobiological modelling appears to be very sensitive to model and parameter selection giving clinically acceptable results in certain cases selectively (relative seriality model with Seppenwoolde et al and Gagliardi et al parameter sets). The use of published parameters should be considered as safe only after their examination using local clinical data. The variation of inter-patient radiosensitivity seems to play a significant role in the prediction of such low incidence rate complications. Scoring grades were combined to give stronger evidence of radiation pneumonitis since their differences could not be strictly associated with dose. This obviously reveals a weakness of the scoring related to this endpoint, and implies that the probability of radiation pneumonitis induction may be too low to be statistically analysed with high accuracy, at least with the latest advances of dose delivery in breast radiotherapy.

Adult↗

Dose-response relations for anal sphincter regarding fecal leakage and blood or phlegm in stools after radiotherapy for prostate cancer. Radiobiological study of 65 consecutive patients.

BACKGROUND: The estimation of the parameters that describe the dose-response relations of anal sphincter regarding the clinical endpoints of fecal leakage and blood or phlegm in stools is important in the optimization of prostate cancer radiotherapy. Also, the validity of the relative seriality model for this clinical case needs to be examined by associating the clinical follow-up results with the predicted complication rates. PATIENTS AND METHODS: In this study, 65 patients who received radiation therapy for clinically localized prostate adenocarcinoma are analyzed. The clinical treatment outcome and the three-dimensional dose distribution delivered to anal sphincter were available for each patient. A questionnaire was used for assessing the clinical bowel and urinary symptoms. A maximum likelihood fitting was performed to calculate the best estimates of the parameters used by the relative seriality model. The clinical utilization of the calculated parameters in predicting anal sphincter complication probabilities was illustrated by applying the best estimate of the parameters to a subset of the patient population. RESULTS: The estimated values of the parameters for the two clinical endpoints are D (50) = 70.2 Gy, gamma = 1.22, s = 0.35 for fecal leakage and D (50) = 74.0 Gy, gamma = 0.75, s approximately 0 for blood or phlegm in stools. The standard deviations of the parameters were also calculated together with the confidence intervals of the dose-response curves. The analysis proved that the treatment outcome pattern of the patient material can suitably be reproduced by the relative seriality model (probability of finding a worse fit = 60.2%, the area under the receiver operating characteristic curve = 0.72 and 0.69 and chi(2)-test = 0.97 and 0.86, respectively). CONCLUSION: Fecal leakage is characterized by a medium relative seriality whereas blood or phlegm in stools was found to have strong volume dependence (low relative seriality). Diminishing the biologically effective uniform dose to anal sphincter < 40-45 Gy may significantly reduce the risk of fecal leakage or blood or phlegm in stools for patients irradiated for prostate cancer.

Aged↗

Statistical methods for clinical verification of dose-response parameters related to esophageal stricture and AVM obliteration from radiotherapy.

The purpose of this work is to provide some statistical methods for evaluating the predictive strength of radiobiological models and the validity of dose-response parameters for tumour control and normal tissue complications. This is accomplished by associating the expected complication rates, which are calculated using different models, with the clinical follow-up records. These methods are applied to 77 patients who received radiation treatment for head and neck cancer and 85 patients who were treated for arteriovenous malformation (AVM). The three-dimensional dose distribution delivered to esophagus and AVM nidus and the clinical follow-up results were available for each patient. Dose-response parameters derived by a maximum likelihood fitting were used as a reference to evaluate their compatibility with the examined treatment methodologies. The impact of the parameter uncertainties on the dose-response curves is demonstrated. The clinical utilization of the radiobiological parameters is illustrated. The radiobiological models (relative seriality and linear Poisson) and the reference parameters are validated to prove their suitability in reproducing the treatment outcome pattern of the patient material studied (through the probability of finding a worse fit, area under the ROC curve and chi2 test). The analysis was carried out for the upper 5 cm of the esophagus (proximal esophagus) where all the strictures are formed, and the total volume of AVM. The estimated confidence intervals of the dose-response curves appear to have a significant supporting role on their clinical implementation and use.

Angiography↗

Prediction of AVM obliteration after stereotactic radiotherapy using radiobiological modelling.

This study was carried out in order to derive the radiobiological parameters of the dose-response relation for the obliteration of arteriovenous malformation (AVM) following single fraction stereotactic radiotherapy. Furthermore, the accuracy by which the linear Poisson model predicts the probability of obliteration and how the haemorrhage history, location and volume of the AVM influence its radiosensitivity are investigated. The study patient material consists of 85 patients who received radiation for AVM therapy. Radiation-induced AVM obliterations were assessed on the basis of post-irradiation angiographies and other radiological findings. For each patient the dose delivered to the clinical target volume and the clinical treatment outcome were available. These data were used in a maximum likelihood analysis to calculate the best estimates of the parameters of the linear Poisson model. The uncertainties of these parameters were also calculated and their individual influence on the dose-response curve was studied. AVM radiosensitivity was assumed to be the same for all the patients. The radiobiological model used was proved suitable for predicting the treatment outcome pattern of the studied patient material. The radiobiological parameters of the model were calculated for different AVM locations, bleeding histories and AVM sizes. The range of parameter variability had considerable effect on the dose-response curve of AVM. The correlation between the dosimetric data and their corresponding clinical effect could be accurately modelled using the linear Poisson model. The derived response parameters can be introduced into the clinical routine with the calculated accuracy assuming the same methodology in target definition and delineation. The known volume dependence of AVM radiosensitivity was confirmed. Moreover, a trend relating AVM location with its radiosensitivity was observed.

Adolescent↗