PubMed Health⌕ Search

Biomedical subjects

Kyung Won Ro

Publications and source records attributed to Kyung Won Ro.

8 recordsLinked to original sources

Plastic microchip liquid chromatography-matrix-assisted laser desorption/ionization mass spectrometry using monolithic columns.

A prototype array of monolithic liquid chromatography (LC) columns was prepared in a plastic microfluidic device for the off-line interface with matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The microfluidic channels were fabricated on a cyclic olefin copolymer (COC) plate by hot embossing. An array of methacrylate monolithic columns was prepared in the microfluidic channels by UV-initiated polymerization. The deposition system employed a pulsed electric field to transfer the effluents from multiple columns directly onto MALDI targets with a non-contact deposition method reported by Ericson et al. [C. Ericson, Q.T. Phung, D.M. Horn, E.C. Peters, J.R. Fitchett, S.B. Ficarro, A.R. Salmon, L.M. Brill, A. Brock, Anal. Chem. 75 (2003) 2309]. To characterize the off-line interface of the multiple-channel microchip LC and the MALDI-MS for the analysis of peptide mixtures, the separation efficiency and reproducibility tests in each column were carried out by separating a peptide mixture from tryptic digested proteins and depositing the multiple effluents simultaneously on the MALDI target plate. Using a MALDI-TOF mass spectrometer with a mass accuracy of +/-1 Da for peptide assignments of digested bovine serum albumin (BSA), amino acid sequence coverage of around 59% was obtained for the microchip LC-MALDI-MS compared to 23% obtained by the MALDI-MS method without LC separation. In sensitivity tests for the detection of low abundance proteins in the presence of high concentration protein mixtures, as low as 10 fmol/mul (S/N = 10) of a spiked peptide in 1 microg of digested BSA could be detected. In the analysis of a mixture of three digested proteins (BSA, myoglobin, and cytochrome c), more than twice the amino acid sequence coverage was obtained for the microchip LC-MALDI-MS compared to MALDI-MS alone.

Cytochromes c↗

Monolithic media in microfluidic devices for proteomics.

Considerable effort has been invested in the development of integrated microfluidic devices for fast and highly efficient proteomic studies. Among various fabrication techniques for the preparation of analytical components (separation columns, reactors, extractors, valves, etc.) in integrated microchips, in situ fabrication of monolithic media is receiving increasing attention. This is mainly due to the ease and simplicity of preparation of monolithic media and the availability of various precursors and chemistries. In addition, UV-initiated photopolymerization technique enables the incorporation of multiple analytical components into specified parts of a single microchip using photomasks. This review summarizes preparation methods for monolithic media and their application as microfluidic analytical components in microchips.

Microfluidic Analytical Techniques↗

Integrated light collimating system for extended optical-path-length absorbance detection in microchip-based capillary electrophoresis.

We have developed an integrated light collimating system with a microlens and a pair of slits for extended optical path length absorbance detection in a capillary electrophoresis (CE) microchip. The collimating system is made of the same material as the chip, poly(dimethylsiloxane) (PDMS), and it is integrated into the chip during the molding of the CE microchannels. In this microchip, the centers of an extended 500-microm detection cell and two optical fibers are self-aligned, and a planoconvex microlens (r = 50 microm) for light collimation is placed in front of a light-delivering fiber. To block stray light, two rectangular apertures, realized by a specially designed three-dimensional microchannel, are made on each end of the detection cell. In comparison to conventional extended detection cell having no collimator, the percentage of stray radiation readout fraction in the collimator integrated detection cell is significantly reduced from 31.6 to 3.8%. The effective optical path length is increased from 324 to 460 microm in the collimator integrated detection cell. The detection sensitivity is increased by 10 times in the newly developed absorbance detection cell as compared to an unextended, 50-microm-long detection cell. The concentration detection limit (S/N = 3) for fluorescein in the collimator integrated detection cell is 1.2 microM at the absorbance detection limit of 0.001 AU.

Journal Article↗

Precolumn diastereomerization and micellar electrokinetic chromatography on a plastic microchip: rapid chiral analysis of amino acids.

Precolumn derivatization and chiral separation of DL-amino acids based on diastereomerization have been performed on an integrated poly(dimethylsiloxane) microchip. Diastereomeric derivatives were formed in a microfabricated precolumn reactor by the reaction of amino acid enantiomers with o-phthaldialdehyde/2,3,4,6-tetra-O-acetyl-1-thio-beta-D-glucopyranose (OPA/TATG), and separated by MEKC in an achiral environment without chiral selectors in the running buffer. Optimized precolumn reactions and chiral separations of amino acids were achieved within 2.5 min. Resolutions of diastereomers of OPA/TATG-amino acids were in the range of 2.5-6.1 at optimized separation conditions. Simultaneous separation of a mixture of five chiral amino acids was successfully performed in a single run in less than 100 s.

Amino Acids↗

Capillary high-performance liquid chromatography-electrospray ionization mass spectrometry using monolithic columns and carbon fiber electrospray ionization emitters.

Monolithic columns having long hydrocarbon chains were prepared by in-situ polymerization in capillary fused silica tubing. The capillary columns were coupled with a newly developed carbon fiber electrospray ionization (ESI) emitter for proteomic analysis using sheathless capillary HPLC-ESI mass spectrometry (MS). The sample loading capacity and chromatographic performance of the styrene-based monolithic column, which was prepared by photo-polymerization of octylstyrene (OS) and divinylbenzene (DVB) were compared with that of the methacrylate-based monolithic column composed of lauryl methacrylate (LMA) and ethylene dimethacrylate (EDMA). The sample loading ability of tryptic digested protein in poly-OS (POS)-DVB column was higher than that of poly-LMA (PLMA)-EDMA column, possibly due to the irregular and rugluous surface offering a greater surface area of POS-DVB stationary phase. The POS-DVB column also provided better separation efficiency in the separation of high concentration (10 microg) of tryptic digested albumin bovine serum (BSA). Due to the successful interface of a highly efficient monolithic column and a stable, durable carbon fiber emitter, low femtomole levels of peptides were successfully separated and identified in the presence of large amounts of tryptic digested protein.

Amino Acid Sequence↗

Electrospray ionization with a pointed carbon fiber emitter.

A new type of electrospray ionization emitter employing a pointed carbon fiber has been developed for interfacing nanoliquid sampling techniques to mass spectrometry. The pointed carbon fiber protruding from an orifice with a surrounding hydrophobic surface confines a small Taylor cone at the tip, which generates a stable electrospray at the tip point. The small Taylor cone improves the electrospray efficiency thereby enhancing the detection limit. This emitter is rugged and able to generate stable electrospray over a wide range of flow rate, ESI voltage, and surface tension variation. Using a solution of angiotensin I, the carbon fiber emitter in 75-microm-i.d. fused-silica tubing was shown to give ion current comparable to that from a commercial 8 microm orifice nanospray emitter. Use of the emitter for ESI-MS/MS analysis of peptides was examined by infusing a mixture of cytochrome c and myoglobin tryptic digest peptides. Protein identification was demonstrated at the level of less than 1 fmol of the peptide consumed. The use of the carbon fiber emitter for interfacing monolithic capillary HPLC to MS was also demonstrated.

Animals↗

Capillary electrochromatography and preconcentration of neutral compounds on poly(dimethylsiloxane) microchips.

Capillary electrochromatography (CEC) and preconcentration of neutral compounds have been realized on poly(dimethylsiloxane) (PDMS) microchips. The channels are coated with polyelectrolyte multilayers to avoid absorption of hydrophobic analytes into PDMS. The structures of a microchip include an injector and a bead chamber with integrated frits, where the particles of the stationary phase are completely retained. Dimensions of the frit structures are 25 micro mx20 micro m, and the space between the structures is 3 micro m. A neutral compound, BODIPY, that is strongly absorbed into native PDMS, is successfully and selectively retained on octadecylsilane-coated silica beads in the bead chamber with a concentration enhancement of up to 100 times and eluted with elution buffer solution containing 70% acetonitrile. Preconcentrations and CEC separations of coumarins have been conducted with the same device and achieved complete separations in less than 50 s.

Acetonitriles↗

Poly(dimethylsiloxane) microchip for precolumn reaction and micellar electrokinetic chromatography of biogenic amines.

We have demonstrated that precolumn derivatization and capillary electrophoresis separation on a poly(dimethylsiloxane) (PDMS) microchip can be realized as efficient as those on glass microchips. In an optimized condition of micellar electrokinetic chromatography (MEKC), using 25 mM sodium borate buffer (pH 10.0) with 25 mM sodium dodecyl sulfate (SDS) and 5% v/v methanol, the electroosmotic flow in an oxidized PDMS microchip is stabilized within 3% for days. By employing a fluorometric derivatization with o-phthaldialdehyde (OPA) in an optimally designed reaction chamber, four most important biogenic amines occurring in foods, histamine, tyramine, putrescine, and tryptamine, are quantitatively determined in less than 1 min at the levels applicable to real samples. The migration behaviors of anionic OPA-derivatized biogenic amines under the MEKC conditions are analyzed, and it has been found that under our separation conditions, the electrophoretic mobility of the SDS micelles is significantly greater than those of the anions in the aqueous phase. The channel manifold in a PDMS substrate is fabricated using replica molding against a thick photoresist, SU-8, pattern generated by photolithography. The plate with the microchannel pattern is strongly, irreversibly bonded to another PDMS plate by using a new bonding technique, which employs surface oxidation by corona discharge generated from a cheap, handy source, Tesla coil.

Biogenic Amines↗