PubMed HealthSearch

Biomedical subjects

L A Beauregard

Publications and source records attributed to L A Beauregard.

10 recordsLinked to original sources

Effects of exercise on signal-averaged electrocardiogram.

Signal averaging can be used to assess changes in myocardial activation under a variety of physiological conditions including stress. This study prospectively evaluated patients who underwent rest and exercise recording of signal-averaged electrocardiograms. The 163 patients were divided into three groups based on thallium results: normal (group I), reperfusion (group II), and fixed defect (group III). Patients in group I showed shortening of the high frequency duration (P = 0.02) and the duration of the low amplitude signal (P = 0.024) after exercise. In these patients the terminal root mean square amplitude (RMSA) also increased significantly (P = 0.005). However, patients who were in either group II or group III showed little change in signal averaging measurements after exercise. The amplitude of the QRS in V5 and the RMSA of the total QRS also increased in all groups following exercise, with a lesser increase in the patients with reperfusion by thallium imaging (group II). There was no change among groups in the incidence of ventricular late potentials with exercise. This suggests that patients with ischemia or infarction may not have the same response to an increase in sympathetic tone with exercise as patients without abnormalities of cardiac perfusion. The clinical implications of these findings may include demonstration that an area of slow conduction exists in these latter two groups of patients.

Adult

Signal-averaged ECG prior to and serially after thrombolytic therapy for acute myocardial infarction.

Signal averaging has been performed to evaluate late potentials following infarction and the administration of thrombolytic therapy. Most studies have recorded signal-averaged electrocardiograms (SAECGs) at least 12 hours after the onset of the infarction. In this study, SAECGs were recorded before thrombolytic therapy and serially over 7-10 days following infarction in 21 patients. The high frequency QRS duration was significantly shortened at 1 and 24 hours compared to presentation (96.8 +/- 11.3 ms and 93.4 +/- 8.0 ms vs 103.3 +/- 14.3 ms, respectively, P < 0.05) and there was an increase in the terminal voltage over time, significant at 1 hour and 3 days (57.3 +/- 29.1 microV and 58.6 +/- 44.7 microV vs 44.4 +/- 35.5 microV, respectively, P < 0.01). Five patients met criteria for ventricular late potentials on at least one SAECG. The prevalence of late potentials was higher in patients with Q wave infarctions, or with occluded infarct related arteries. These changes in myocardial activation may be related to ischemia and reperfusion, and may not correlate with the development of a fixed substrate for reentry.

Electrocardiography

Perceived and actual risks of driving in patients with arrhythmia control devices.

BACKGROUND: We surveyed patient attitudes about driving and about driving restrictions for patients with automatic defibrillators and pacemakers, and we assessed risk of arrhythmias occurring during driving. METHODS: One hundred two patients responded to a questionnaire (57 patients with defibrillators and 45 patients with pacemakers) about driving habits and opinions on restriction of patients who have devices and want to drive. In addition, the literature was reviewed for approximate incidences of sudden death and syncopal or nonsyncopal device therapy to estimate risk while driving of having a defibrillator discharge. RESULTS: Thirty-two patients with defibrillators (56%) and 28 patients with pacemakers (62%) currently drove an average of 196 and 161 km/wk, respectively. Most patients felt that driving was a right and 75% felt that restriction imposed a hardship on them. Respondents felt that common sense, limited distances, or physician input should set driving limitations. A minority felt that no restrictions should be placed on these drivers or that they should not drive at all. The risks of sudden death and syncopal and nonsyncopal defibrillator discharge were estimated at 0.0009%, 0.0011%, and 0.0015% per kilometer driven, respectively, based on weekly kilometers and published occurrences of these phenomena. CONCLUSIONS: Patients perceive that driving is their right and that there is a low risk of an arrhythmic event behind the wheel. The estimated risk and published accounts of sudden death support this. However, concurrent medical problems and stresses imposed by driving may increase risk. The physician must make reasonable recommendations to ensure patient and public safety, keeping in mind both state and federal driving regulations and reporting requirements.

Aged

Combined ambulatory electroencephalographic and electrocardiographic recordings for evaluation of syncope.

Evaluation of patients with syncope often includes a battery of noninvasive tests. In this study, 45 patients (26 with suspected neurologic and 19 with suspected cardiac syncope) were evaluated with simultaneous 24-hour electroencephalographic (EEG) and 2-channel electrocardiographic (ECG) recordings. Isolated cardiac rhythm abnormalities were noted in 21 patients, but none of these was symptomatic and no definitive arrhythmias occurred. Isolated EEG abnormalities were noted in 11 patients, 5 of whom had EEG abnormalities consistent with seizure disorders. Simultaneous EEG and ECG abnormalities were seen in 4 patients. In 2 cases, a previously unsuspected etiology for syncope was found: seizures in 1 patient with heart disease, and sinus pauses in another thought to have a seizure disorder. Thus, combined ambulatory EEG/ECG monitoring may prove useful in the evaluation of some patients with syncope.

Adolescent

Spontaneous changes in ventricular tachycardia cycle length.

Understanding spontaneous fluctuations in ventricular tachycardia cycle length is required to develop algorithms for ventricular tachycardia detection and termination. Variations in cycle length, time to stable cycle length and the range of RR intervals during ventricular tachycardia were analyzed in 74 episodes of sustained monomorphic ventricular tachycardia induced in patients not taking antiarrhythmic medication. Linear regression demonstrated cycle length variability to decrease over time (41 +/- 24 to 17 +/- 19 ms, p less than 0.001). Slower ventricular tachycardia had more cycle length variability than faster ventricular tachycardia (p less than 0.001). Ventricular tachycardia that was initially more variable tended to remain more variable (p less than 0.001). Fifty-four percent of episodes stabilized within the first 15 beats, 75% by 30 beats and 93% by 50 beats. The number of beats to stable cycle length was independent of ventricular tachycardia rate. The average range in cycle length per episode was 127 +/- 72 ms; 12% of ventricular tachycardia episodes varied by less than 50 ms and 45% by less than 150 ms. The maximal range in RR intervals from a single episode of ventricular tachycardia was 290 ms. Therefore, ventricular tachycardia demonstrates a wide range of cycle lengths and has time-dependent changes in variability and stability. These cycle length changes should be considered in the algorithms for ventricular tachycardia detection and termination by automatic antitachycardia devices.

Algorithms

Differentiation of arrhythmias by measurement of intracardiac pressures in man.

Antitachycardia devices currently use sustained high rate, abrupt changes in cycle length, and probability density function to determine the onset of ventricular tachycardia. Hemodynamic changes occur with the onset of tachycardia and may provide a method of discriminating supraventricular from ventricular tachycardia. In this study, patients had atrial and ventricular pressures measured during rapid atrial and ventricular pacing. Right atrial pressure increased significantly with ventricular pacing but not with atrial pacing. Right ventricular pressures did not significantly differ with atrial or ventricular pacing. The change in atrial pressure compared to baseline was greater, with ventricular pacing compared to atrial pacing. Right ventricular pressure increased compared to baseline with atrial or ventricular pacing, but there was no significant difference between pacing modalities. Measurement of right atrial pressure might prove useful in discriminating supraventricular from ventricular tachycardia.

Atrial Function, Right