PubMed Health⌕ Search

Biomedical subjects

L A Currie

Publications and source records attributed to L A Currie.

5 recordsLinked to original sources

Some case studies of skewed (and other ab-normal) data distributions arising in low-level environmental research.

Three general classes of skewed data distributions have been encountered in research on background radiation, chemical and radiochemical blanks, and low levels of 85Kr and 14C in the atmosphere and the cryosphere. The first class of skewed data can be considered to be theoretically, or fundamentally skewed. It is typified by the exponential distribution of inter-arrival times for nuclear counting events for a Poisson process. As part of a study of the nature of low-level (anti-coincidence) Geiger-Muller counter background radiation, tests were performed on the Poisson distribution of counts, the uniform distribution of arrival times, and the exponential distribution of inter-arrival times. The real laboratory system, of course, failed the (inter-arrival time) test--for very interesting reasons, linked to the physics of the measurement process. The second, computationally skewed, class relates to skewness induced by non-linear transformations. It is illustrated by non-linear concentration estimates from inverse calibration, and bivariate blank corrections for low-level 14C-12C aerosol data that led to highly asymmetric uncertainty intervals for the biomass carbon contribution to urban "soot". The third, environmentally, skewed, data class relates to a universal problem for the detection of excursions above blank or baseline levels: namely, the widespread occurrence of ab-normal distributions of environmental and laboratory blanks. This is illustrated by the search for fundamental factors that lurk behind skewed frequency distributions of sulfur laboratory blanks and 85Kr environmental baselines, and the application of robust statistical procedures for reliable detection decisions in the face of skewed isotopic carbon procedural blanks with few degrees of freedom.

Journal Article↗

Interlaboratory comparison of autoradiographic DNA profiling measurements. 4. Protocol effects.

The observed total interlaboratory uncertainty in restriction fragment length polymorphism (RFLP) measurements is sufficiently small to be of little significance given current forensic needs. However, as the number of RFLP data increase, further reduction in the total uncertainty could help minimize the resources required to evaluate potential profile matches. The large number of data available enable quantitative estimation of the within-laboratory imprecision and among-laboratory bias contributions to the total uncertainty. Some small but consistent among-laboratory measurement biases can be attributed to specific procedural or materials differences. The bias direction is often fragment-specific and thus unpredictable for unknown samples. Actions that would minimize currently recognized sources of interlaboratory bias include the following: (1) all laboratories should use the same algorithm for data interpolation, (2) all laboratories should use the same sizing ladders, (3) each laboratory should prepare control DNA and sample DNA in the same manner and with the identical reagents, (4) all laboratories should adopt a uniform policy on ethidium bromide use, and (5) all laboratories should adopt the same control DNA sizing acceptability criteria.

Autoradiography↗

Interlaboratory comparison of autoradiographic DNA profiling measurements. 2. Measurement uncertainty and its propagation.

Identifying the intrinsic sources of measurement uncertainty greatly facilitates control and further optimization of a measurement system. We have developed a model which quantitatively describes the observed interlaboratory variability of autoradiographic DNA band sizing. The model focuses on optical imaging measurements of band position and the calibration techniques used to convert measured band position to reported band size. The imaging component of measurement variability is described as a 0.05-0.2% standard deviation in determining the relative location of sample and calibration bands on a given film image. While developed solely with optical imaging information, the model is consistent with interlaboratory band sizing measurement variability observed with pristine samples. This interlaboratory variability can be modeled as a 0.2-0.4% standard deviation in the relative positions of sample and calibration bands across different electrophoretic gels. Further band sizing protocol standardization among laboratories would thus be expected to achieve at best a 2-fold reduction in interlaboratory band sizing variability.

Autoradiography↗

Alcoholic liver disease in black men with G6PD deficiency.

Glucose-6-phosphate dehydrogenase (G6PD) deficiency of the type commonly encountered in Afro-American blacks has been associated with an increased severity of viral hepatitis. Decreased activity of the enzyme has been demonstrated in liver tissue of affected individuals. We studied 21 patients with alcoholic liver disease and G6PD deficiency who were identified through the VA Cooperative Study of Sickle Trait and G6PD Deficiency and compared them with 21 black patients with alcoholic liver disease and normal G6PD levels. A trend suggested the severity of liver disease might be less in G6PD-deficient patients. We conclude that G6PD deficiency is not associated with increased severity of alcoholic liver disease.

Adult↗

Detection and quantification limits: basic concepts, international harmonization, and outstanding ("low-level") issues.

A brief review is given of concepts, basic definitions, and terminology for metrological detection and quantification capabilities, representing harmonized recommendations and norms of the International Union of Pure and Applied Chemistry (IUPAC) and the International Organization for Standardization (ISO), respectively. Treatment of the (low-level) blank and variance function are discussed in some detail, together with special problems arising with detection decisions and the reporting of low-level data. Key references to the international documents follow, as well as specialized references addressing very low-level counting data, skewed environmental blank distributions, and multiple and multivariate detection decisions.

Journal Article↗