A comparative study on different methods of automatic mesh generation of human femurs.

The aim of this study was to evaluate comparatively five methods for automating mesh generation (AMG) when used to mesh a human femur. The five AMG methods considered were: mapped mesh, which provides hexahedral elements through a direct mapping of the element onto the geometry; tetra mesh, which generates tetrahedral elements from a solid model of the object geometry; voxel mesh which builds cubic 8-node elements directly from CT images; and hexa mesh that automatically generated hexahedral elements from a surface definition of the femur geometry. The various methods were tested against two reference models: a simplified geometric model and a proximal femur model. The first model was useful to assess the inherent accuracy of the meshes created by the AMG methods, since an analytical solution was available for the elastic problem of the simplified geometric model. The femur model was used to test the AMG methods in a more realistic condition. The femoral geometry was derived from a reference model (the "standardized femur") and the finite element analyses predictions were compared to experimental measurements. All methods were evaluated in terms of human and computer effort needed to carry out the complete analysis, and in terms of accuracy. The comparison demonstrated that each tested method deserves attention and may be the best for specific situations. The mapped AMG method requires a significant human effort but is very accurate and it allows a tight control of the mesh structure. The tetra AMG method requires a solid model of the object to be analysed but is widely available and accurate. The hexa AMG method requires a significant computer effort but can also be used on polygonal models and is very accurate. The voxel AMG method requires a huge number of elements to reach an accuracy comparable to that of the other methods, but it does not require any pre-processing of the CT dataset to extract the geometry and in some cases may be the only viable solution.

Algorithms↗

Computerized mechanical validation of custom-made stems.

The new community laws regarding medical devices require that custom-made devices be prescribed by the surgeon, who assumes responsibility for the device along with the manufacturer. It is the purpose of this study to indicate a method that allows use to check whether custom-made prostheses in particular conform to the requirements established by European laws; these are prostheses produced in a single model and that have rather short development and realization times. The pre-clinical method of validation proposed, based on a calculation with finite elements, was first verified by in vitro measurements and then used to evaluate 15 cases selected among the most critical ones in terms of size and/or geometrical irregularity from a group of 100 stems that had already been implanted. The method proposed was confirmed to be accurate and reliable; in 3 out of 15 stems analyzed we found values for mechanical resistance that were less than minimum values required by law.

Arthroplasty, Replacement, Hip↗