PubMed Health⌕ Search

Biomedical subjects

L Blankevoort

Publications and source records attributed to L Blankevoort.

38 records · Page 3Linked to original sources

Helical axes of passive knee joint motions.

The purpose of this study was to determine finite helical axes for passive knee joint motions in vitro and to evaluate the descriptive value of the finite helical axes for step-by-step flexion motions, with respect to consistency and reproducibility. An accurate Roentgenstereophotogrammetric system was used for motion measurements. Four knees were tested in a motion and loading rig with one and the same experimental protocol. A fifth specimen was used to study the effects of some of the experimental conditions on the axis parameters. On the basis of earlier reported motion characteristics in terms of Euler rotations and translations, two motion pathways were chosen to be reported here: a flexion motion with an internal torque of 3 Nm and one with an external torque of 3 Nm on the tibia. The positions and orientations of the axes were described relative to the insertions of the four major ligaments and the geometry of the articular surfaces of the femur, and also as intersections with a medial and a lateral sagittal plane. The three-dimensional patterns of the helical axes of the four knee specimens were found to be highly reproducible and consistent for each of the two motion pathways. The axis patterns were not unique, but reflected the particular combination of flexion and axial rotation for each particular motion pathway. Although small, the helical translations indicated medial motions of the tibia relative to the femur. This medial helical translation was more pronounced for the internal pathway compared with the external pathway. Above 70 degrees flexion, the axes move posteriorly relative to the femur.

Biomechanical Phenomena↗

The envelope of passive knee joint motion.

The purpose of this study is to create an accurate experimental database for the passive (in vitro) freedom-of-motion characteristics of the human knee joint on a subject to subject basis, suitable for the verification and enhancement of mathematical knee-joint models. Knee-joint specimens in a six degree-of-freedom motion rig are moved through flexion under several combinations of external loads, including tibial torques, axial forces and AP-forces. Euler rotation angles and translation vectors, describing the relative, spatial motions of the joint are measured using an accurate Roentgen Stereo Photogrammetric system. Conceptually the joint is considered as a two degrees-of-freedom of motion mechanism (flexion-tibial rotation), whereby the limits of internal and external tibial rotation are defined at torques of +/- 3 Nm. The motion pathways along these limits are defined as the envelopes of passive knee joint motion. It is found that these envelope pathways are consistent and hardly influenced by additional axial forces up to 300 N and AP-forces of 30 N. Within the envelope of motion, however, the motion patterns are highly susceptible to small changes in the external load configuration. It is shown that the external tibial rotation during extension ('screw-home mechanism') is not an obligatory effect of the passive joint characteristics, but a direct result of the external loads. Anatomical differences notwithstanding, the inter-individual discrepancies in the motion patterns of the four specimens tested, showed to be relatively small in a qualitative sense. Quantitative differences can be explained by small differences in the alignment of the coordinate systems relative to the joint anatomy and by differences in rotatory laxity.

Adult↗