PubMed Health⌕ Search

Biomedical subjects

L Branco

Publications and source records attributed to L Branco.

At least 19 recordsLinked to original sources

[Evaluation of the safety of stress echocardiography in Spain and Portugal].

UNLABELLED: INTRODUCTION. There are few studies that evaluate the safety of stress echocardiography with discordant results. They are done in well-trained centers with highly selected populations leading to selection bias. OBJECTIVE: To assess the safety of the different modalities of stress echocardiography in Spain and Portugal. METHOD: Severe complications were retrospectively analyzed during the stress echocardiography performed in 29 hospitals in Portugal and Spain, from the beginning of their activity to September, 1999. In this period 22,105 stress echocardiograms were performed: 10,975 exercise echos, 2,969 low dose dobutamine echos, 6,832 high dose dobutamine echocardiograms, 1,276 dypiridamole echocardiograms, 41 paced echocardiograms and 12 with adenosine. A complication was defined as severe when it was life-threatening or led to hospital admission. RESULTS: We registered 26 complications, one death, 3 ventricular fibrillations, 10 sustained ventricular tachycardias, 2 complete atrioventricular blocks, 6 acute myocardial infarctions, 2 ruptures of the free wall or ventricular septal defects, 1 transient ischemic attack and 1 severe symptomatic hypotension. We had one severe complication for every 2,743 exercise stress, 1 every 1,231 dypiridamole, 1 every 325 high dose dobutamine without any complications with low dose dobutamine stress. We found a relationship between experience in dobutamine stress echocardiography and the frequency of complications. Three complications appeared once the test was finished. CONCLUSIONS: The stress echocardiography is a safe technique, but not harmless. The exercise stress echo is the safest of all the modalties of stress echocardiography. There is a relation between experience and the number of complications.

Aged↗

Non-invasive monitoring of pulmonary capillary wedge pressure in heart failure.

OBJECTIVE: To evaluate the usefulness of pulsed Doppler (PD) mitral flow E wave deceleration time (EDcT) to detect and quantify changes of pulmonary capillary wedge pressure (PCWP) in patients (pt) with dilated chronic heart failure (CHF) submitted to tailored therapy. METHODS: In 14 pt with dilated cardiomyopathy (DCM) (59.4+/-10.0 years, 11 males, sinus rhythm), admitted to the ICU because of worsening CHF, serial simultaneous hemodynamic and echocardiographic studies were performed (3-5/pt; overall 49 evaluations). PD mitral flow register was used to measure EDcT and correlated with PCWP at each study. RESULTS: PCWP ranged from 36 to 3 mmHg (17.6+/-8.8) and EDcT from 271 to 52 ms (104.9+/-42.4). The correlation between EDcT and PCWP was -0.65 (PCWP=31.7-0.134EDcT). Using this equation to calculate PCWP, individual absolute values difference (identity error - IE) was 5.6+/-3.5 mmHg (0.4-14.6). In 29 cases (59.2%) IE was >5 mmHg, defined as major error. Considering EDcT percent change (delta%EDcT) and PCWP variation (deltaPCWP) in serial evaluations, we found a correlation of -0.87 (deltaPCWP=-2.83-0.19 delta%EDcT). Using this equation, the IE was 2.3+/-1.6 mmHg (0-5.2) and there were only two (6%) major errors (P<0.0001). CONCLUSIONS: In pt with DCM and advanced CHF, EDcT shows a reasonable correlation with PCWP, but when it is used to calculate PCWP the IE to hemodynamic values is often large. However, our results with EDcT percent change in serial evaluations using a first simultaneous invasive determination, suggest that this technique is reliable for monitoring PCWP and can be particularly useful for pt submitted to tailored therapy.

Adult↗

Cardiac output quantification by Doppler echocardiography in intensive care--limitations and validation.

UNLABELLED: Cardiac output (CO) quantification is primordial to the evaluation of patients with heart failure who are on tailored therapy and under invasive hemodynamic monitoring. Doppler echocardiography can be used to access CO noninvasively, but the concordance between its results and those obtained by invasive methods in paired measurements is still controversial. To our knowledge, no previous studies have assessed the clinical relevance of Doppler echocardiography for CO serial evaluation in patients submitted to tailored therapy. AIM: To evaluate the usefulness of echo-Doppler in the assessment of CO and quantification of changes in CO, compared to thermodilution, in patients with advanced heart failure under hemodynamic monitoring to guide tailored therapy. METHODS: In 20 patients (14 male, 62 +/- 14 years old, all in sinus rhythm), with dilated cardiomyopathy and NYHA IV, admitted to the intensive care unit (ICU), CO was simultaneously determined by Doppler echocardiography (dpCO) and thermodilution (tdCO) in three serial evaluations (overall 60). The dpCO was calculated by multiplying the aortic orifice area by the velocity-time integral of aortic continuous wave Doppler flow and by the heart rate. A difference between tdCO and dpCO of more than 20% was considered a major error. RESULTS: In the overall evaluations, dpCO systematically overestimates tdCO (p = 0.026). The correlation between tdCO and dpCO was 0.81, the mean difference between measurements was 0.40 +/- 0.61 l/min (mean -2SD = -1.62 mean +2SD = 0.81) and 19 (32%) major errors occurred. No significant difference was found between CO percentual variation values assessed by both methods, with a stronger correlation (r = 0.92-p = 0.014) compared to that found for absolute values. On using the dpCO/tdCO ratio in the first evaluation to correct subsequent dpCO, the correlation was fairly good (r = 0.96-p = 0.0002 versus corrected dpCO). The mean difference between paired measurements was significantly lower (0.12 +/- 0.28 l/min-mean 2SD = -0.44 mean +2SD = 0.67), and there were no errors. CONCLUSIONS: CO estimated by Doppler echocardiography has a good correlation with thermodilution although with a weak concordance between paired results in patients with dilated cardiomyopathy and advanced heart failure admitted to the ICU for tailored therapy. Our results with dpCO percentual change in repeated evaluations and with corrected dpCO value after a single simultaneous invasive determination suggest that Doppler echocardiography is a valid method for clinical purposes, allowing us to propose a reduction in the time period of invasive hemodynamic monitoring.

Adult↗

Selective deletion of antigen-specific, activated T cells by a humanized MAB to CD2 (MEDI-507) is mediated by NK cells.

CD2 is a 50-kDa transmembrane glycoprotein that plays an important role in T and natural killer (NT) lymphocyte functions. CD2 serves as both an adhesion molecule and as a costimulatory molecule through interactions with its ligand, CD58, on antigen presenting or target cells. Consistent with earlier studies using a rat anti-CD2 mAb, we have shown that treatment of alloantigen stimulated T lymphocytes with a humanized mAb, MEDI-507 (IgG1, kappa), induced hyporesponsiveness to subsequent stimulation with alloantigen but not to mitogen (phytohemagglutinin). Fluorescence-activated cell sorting analysis of cells from mixed lymphocyte reaction (MLR) treated with MEDI-507 revealed pronounced deletion of T and NK cells, consistent with lack of proliferation in the MLR. MEDI-507 F(ab')2 fragments did not have inhibitory activity or induce deletion of lymphocytes in the MLR. Removal of the NK cell subset by magnetic bead depletion using anti-CD16 and anti-CD56 mAbs eliminated both the T cell deletion and the inhibitory effect. Reconstitution of NK depleted responder populations using autologous NK cells restored the MEDI-507-mediated deletion activity to levels measured in the original MLR. Formaldehyde-fixed NK cells failed to mediate the MEDI-507-induced deletion effect. Altogether, our studies indicate that activated T cells with MEDI-507 bound to CD2 are preferential targets for autologous NK cells through a nonapoptotic cytotoxic mechanism.

Adult↗

[The semiquantitative evaluation of systemic vascular resistances in heart failure via an analysis of Doppler aortic flow].

UNLABELLED: In patients with advanced heart failure (HF) submitted to tailored therapy, monitoring of systemic vascular resistance (SVR) is essential to establish an adequate hemodynamic response, being one of the end-points to achieve SVR < 18 Wood U (WU). PURPOSE: To correlate SVR value with parameters derived from the analysis of echo-Doppler aortic flow in patients with HF on tailored therapy, in order to allow a non-invasive semiquantitative evaluation of this hemodynamic end-point. METHODS: In 13 patients with dilated cardiomyopathy (eight idiopathic, five ischemic) and advanced HF (mean age 60 +/- 10 years, 10 male, all in sinus rhythm, NYHA class IV), admitted in the ICU and submitted to tailored therapy, serial simultaneous hemodynamic and echocardiographic studies were performed (2 to 5 per patient, overall 43 evaluations). The following parameters derived from the analysis of continuous wave aortic Doppler flow were analysed: peak velocity, acceleration, deacceleration and ejection times, systolic time intervals ratio, mean acceleration, mean deacceleration, acceleration, deacceleration and overall systolic flow velocity time integrals. RESULTS: SVR ranged from 10.4 to 41.9 WU (mean = 21.7, SD = 6.9). A significant correlation was found only with mean deacceleration (MnDc)-r = -0.60. MnDc ranged from 362 to 1162 cm/s2 (mean = 667, SD = 188) and proved to be independent from heart rate, systolic, diastolic and mean blood pressure, capillary wedge pressure, cardiac output, cardiac index and ejection volume. MnDc < 700 cm.s2 occurred in 25/28 evaluations with SVR > 18 WU and only in 3/15 evaluations with SVR < 18 WU-p = 0.00003. A MnDc value < 700 cm.s2 showed sensitivity = 89%, specificity = 80%, and predictive value = 89% for SVR > 18 WU (Kappa index = 0.693). CONCLUSION: Mean deacceleration of aortic continuous wave flow is reliable for semiquantitative evaluation of systemic vascular resistance and can be particularly useful for patients with advanced heart failure submitted to tailored therapy.

Adult↗

[The sinus venosus type of interatrial communication: its diagnosis by transesophageal echocardiography].

Transthoracic echocardiography has important limitations in the diagnosis of sinus venosus atrial septal defects in adults because of the posterior location of the defect. We review the role of transesophageal echocardiography in the diagnosis of this congenital heart disease in nine patients, as well as in the identification of associated abnormal pulmonary venous connections.

Adult↗

[A pseudoaneurysm of the mitral-aortic intervalvular fibrosis after aortic valve replacement].

A 58-year-old male underwent a transesophageal echocardiogram for suspected aortic valve infective endocarditis, four years after surgery. The examination, performed with a multiplane probe, showed a pulsatile (systolic expansion) echo-free cavity in the intervalvular mitral-aortic region, communicating with the left ventricle outflow tract, with no signs of rupture to the left atrium or the aorta. These findings meet the criteria for the diagnosis of pseudoaneurysm of the mitral-aortic intervalvular fibrosa.

Aneurysm, False↗

[Echocardiography and new diagnostic criteria for infective endocarditis].

A review of made of clinical and echocardiographic features of infective endocarditis, emphasizing the contribution to new diagnostic criteria made by Duke University and analysing different studies about their sensitivity and specificity and their advantages over the classic von Reyn criteria. A short historical overview is also made and the importance of echocardiography, particularly the transesophageal approach, for the diagnosis of infective endocarditis and its complications is discussed, bearing in mind the new diagnostic criteria.

Echocardiography, Transesophageal↗