PubMed HealthSearch

Biomedical subjects

L Brewster

Publications and source records attributed to L Brewster.

5 recordsLinked to original sources

Dose-volume histograms.

A plot of a cumulative dose-volume frequency distribution, commonly known as a dose-volume histogram (DVH), graphically summarizes the simulated radiation distribution within a volume of interest of a patient which would result from a proposed radiation treatment plan. DVHs show promise as tools for comparing rival treatment plans for a specific patient by clearly presenting the uniformity of dose in the target volume and any hot spots in adjacent normal organs or tissues. However, because of the loss of positional information in the volume(s) under consideration, it should not be the sole criterion for plan evaluation. DVHs can also be used as input data to estimate tumor control probability (TCP) and normal tissue complication probability (NTCP). The sensitivity of TCP and NTCP calculations to small changes in the DVH shape points to the need for an accurate method for computing DVHs. We present a discussion of the methodology for generating and plotting the DVHs, some caveats, limitations on their use and the general experience of four hospitals using DVHs.

Humans

Histogram reduction method for calculating complication probabilities for three-dimensional treatment planning evaluations.

New tools are needed to help in evaluating 3-D treatment plans because of the large volume of data. One technique which may prove useful is the application of complication probability calculations. A method of calculating complication probabilities for inhomogeneously irradiated normal tissues is presented in this paper. The method uses clinical estimates of tolerance doses for a few discreet conditions of uniform partial organ irradiation, an empirical fit of a continuous function to these data, and a technique (the effective volume method) for transforming nonuniform dose-volume histograms into equivalent uniform histograms. The behavior of the effective volume histogram reduction method for various boundary conditions is reviewed. The use of complication probabilities in evaluating treatment plans is presented, using examples from an NCI 3-D treatment planning contract.

Humans

Three-dimensional photon treatment planning of the intact breast.

Three-dimensional treatment planning for the intact breast was performed on two patients who had undergone CT scanning. A total of 38 treatment plans were evaluated. Multiple plans were evaluated for each patient including plans with and without inhomogeneity corrections, plans using varying photon energies of 60Co, 4 MV, 6 MV, 10 MV, and 15 MV, and three-dimensionally unconstrained plans. Increased hot spots were appreciated in the central axis plane when lung inhomogeneity corrections were used. Additional hot spots were appreciated in off-axis planes towards the cephalad and caudad aspects of the target volume because of lung inhomogeneity corrections and changes in the breast contour. The use of 60Co was associated with an increase in the magnitude and volume of hot spots, whereas the use of higher energy photons such as 10 MV and 15 MV was associated with an unacceptable target coverage at shallow depths. Therefore, for the two patients studied, the use of a medium energy photon beam (such as from a 6 MV linear accelerator) appeared to be the energy of choice for treatment of the intact breast. The three-dimensionally unconstrained plans were able to improve slightly upon the standard plans, particularly with relationship of dose to normal tissue structures. Areas for future research were identified, including the use of tissue compensators.

Adult

Three-dimensional treatment planning for postoperative treatment of rectal carcinoma.

The role of three-dimensional (3-D) treatment planning for postoperative radiation therapy was evaluated for rectal carcinoma as part of an NCI contract awarded to four institutions. It was found that the most important contribution of 3-D planning for this site was the ability to plan and localize target and normal tissues at all levels of the treatment volume, rather than using the traditional method of planning with only a single central transverse slice and simulation films. There was also a slight additional improvement when there were no constraints on the types of plans (i.e., when noncoplanar beams were used). Inhomogeneity considerations were not important at this site under the conditions of planning, i.e., with energies greater than 4 MV and multiple fields. Higher beam energies (15-25 MV) were preferred by a small margin over lower energies (down to 4 MV). The beam's eye view and dose-volume histograms were found quite useful as planning tools, but it was clear that work should continue on better 3-D displays and improved means of translating such plans to the treatment area.

Combined Modality Therapy

Early detection of childhood hearing impairment - problems and possible solutions.

The identification of infants with profound hearing loss is a complex task, and one that is beset with problems. This paper discusses some of these problems and points out a few of the ways by which, hopefully, they are coming closer to solution. The first problem results from the nature of the beast, which seems to have so many social, medical, educational, and political implications. There are also some problems with the high risk register and with screening for hearing loss; but probably the most disturbing are the conflicts that arise between professionals when their aims, objectives, and methods don't quite match. Current progress in the linking up of high risk and screening methodologies is discussed, as well as ways in which existing health care systems can be utilized in deafness detection.

Audiology