PubMed Health⌕ Search

Biomedical subjects

L C Breeding

Publications and source records attributed to L C Breeding.

49 records · Page 3Linked to original sources

The transverse strengths of three denture base resins.

Ten specimens each of (1) Lucitone 199, short- and long-cured, (2) Accelar 20, and (3) Triad materials were broken using a 3-point load on an Instron Universal testing machine after processing and air drying. Five specimens of each resin also were broken after storage in deionized distilled water at 37 degrees C for 30, 60, and 90 days. Triad material demonstrated the lowest transverse strengths of all three materials overall. However, Triad material was unaffected by water storage. The other resins all showed decreased strengths with water storage.

Acrylic Resins↗

The effect of connector design on cement retention in an implant and natural tooth-supported fixed partial denture.

This study investigated the effect of connector design, rigid or nonrigid, on cement retention in a combined implant and natural tooth-supported fixed partial denture. A prepared natural tooth was placed in a Plexiglas block in a manner that it could move approximately the same as a healthy premolar. An endosseous implant was placed in the block so that it was immobile. Joining the prepared tooth and implant was a fixed partial denture that could be made rigid or nonrigid. The natural tooth retainer was cemented to the prepared tooth, and the implant retainer was affixed to the implant fixture with a gold screw. One year of stress was applied to the fixed partial denture by a force simulation machine. Twenty randomly ordered tests were completed, 10 of each connector design. Retentive values for the cemented retainers were recorded and statistically compared by use of Student's independent t test. No significant difference in cement retentive strength between designs was found (p less than 0.05).

Bicuspid↗

Use of a partial-coverage porcelain laminate to enhance clasp retention.

Historically, invasive restorative procedures have been required to create undercuts for removable partial denture retainers where natural undercuts are lacking. Resin-bonding procedures have allowed the development of conservative, minimally invasive methods for creating undercuts. A technique using a partial-coverage porcelain laminate is described.

Composite Resins↗

A double-mix cementation for improved esthetics of resin-bonded prostheses.

An efficient technique is described for reducing incisal discoloration of abutment teeth without creating a cement line. One disadvantage is the need for both opaque and tooth-colored translucent resin cements, but the complex procedure can be facilitated by increasing the working time of the resin cements.

Cementation↗

Carbon dioxide metabolism by Actinomyces viscosus: pathways for succinate and aspartate production.

14C-labeled bicarbonate was incorporated into trichloroacetic acid-insoluble material by cell suspensions of A. viscosus strain M100 and also into the four-carbon fermentation product, succinate, but not into the three-carbon fermentation product, lactate. The initial step in the conversion of 14C-labeled bicarbonate into both trichloroacetic acid-insoluble material and succinate was catalyzed by the enzyme phosphoenolypyruvate carboxylase, which served to convert the glycolytic intermediate, phosphoenolpyruvate, and bicarbonate to the four-carbon compound, oxalacetate. The metabolic fate of oxalacetate was its conversion to either trichloroacetic acid-insoluble material or succinate. One pathway by which oxalacetate may be metabolized into acid-insoluble material is via its conversion to the biosynthetic precursor aspartate by the action of glutamate aspartate aminotransferase. One source of the alpha-amino group of aspartate was the ammonium ion, which could be incorporated into glutamate, the substrate of the glutamate aspartate aminotransferase reaction, by the action of a reduced nicotinamide adenine dinucleotide phosphate-dependent glutamate dehydrogenase whose reducing equivalents could be derived from the nicotinamide adenine dinucleotide phosphate-dependent oxidative reactions of the hexose monophosphate pathway catalyzed by glucose 6-phosphate dehydrogenase and 6-phosphogluconate dehydrogenase. Alternatively, oxalacetate was converted to the fermentation product, succinate, through the sequential action of malate dehydrogenase, fumarase, and succinic dehydrogenase. The resolution and partial purification of phosphoenolpyruvate carboxylase, glutamate aspartate aminotransferase, glutamate dehydrogenase, malate dehydrogenase, fumarase, and succinic dehydrogenase are also reported.

Actinomyces↗

The effect of polishing porcelain laminates on induced I-Bar wear.

Partial-coverage porcelain laminate restorations may successfully be used to create undercuts for removable partial denture abutment teeth. If recontouring of such restorations becomes necessary after placement, surface polishing would be necessary prior to removable partial denture fabrication. In this study the wear of luted porcelain laminates, which received a polished surface treatment and contacting I-bar clasps, was quantified over a simulated 2-year period when subjected to removable partial denture placement and removal. Scanning electron photomicrographs and computer imaging were used for wear measurement. These data were compared to previously recorded data on wear of I-bar tips against human enamel and glazed, luted, porcelain-laminate restorations under the same experimental conditions. No measurable wear was observed on any of the laminate specimens. I-bar clasps tested against the glazed laminate restorations exhibited the greatest mean wear, and those tested against the polished laminates exhibited the least mean wear.

Analysis of Variance↗

Wear of I-bar clasps and porcelain laminate restorations.

Partial-coverage porcelain laminate restorations, placed to provide undercut areas for I-bar direct retainers of removable partial dentures, were evaluated over simulated 2- and 5-year periods of placement and removal movements. SEM photomicrographs and computer imaging were used to quantify wear of the I-bar tips and the contacting laminate surfaces. These data were statistically compared to previously collected data of I-bar clasp tip wear against human enamel under the same experimental conditions. None of the laminate restorations debonded during this investigation. I-bars contacting laminates exhibited significantly more wear than I-bars contacting human enamel; however, the combined laminate-I-bar wear compared to the combined enamel-I-bar wear produced no significant difference.

Dental Clasps↗

In vitro investigation of the wear of resin composite materials and cast direct retainers during removable partial denture placement and removal.

The purpose of this study was to determine whether wear of two resin composite materials and contacting I-bar clasp tips would occur within a simulated RPD placement and removal period of 2 years. The data were compared to enamel with contacting I-bars. Cast I-bar clasps were passed over each specimen in the resin composite and tooth experimental groups (n = 10). Computer digitized image analysis of SEM photomicrographs of the specimens provided data for analysis of wear. Results indicated a statistical difference in the amount of mean wear between the two resin composites and between the I-bar groups. The results from this study suggest that the selection of a resin composite for use as a RPD retentive undercut must be carefully undertaken to avoid excessive wear and loss of retention.

Analysis of Variance↗

The effect of custom tray material type and adhesive drying time on the tensile bond strength of an impression material/adhesive system.

The purpose of this investigation was to compare the tensile bond strength of one poly(vinyl siloxane) impression material/adhesive system to three different custom tray materials 10 minutes, 48 hours, and 7 days after adhesive application. One autopolymerizing (Fastray) and two light-polymerizing (Triad and Extoral) custom tray resins were examined. The Triad tray resin exhibited the significantly highest mean adhesive tensile bond strengths, and the Fastray resin exhibited the lowest. It was also observed that the 48-hour adhesive drying time group exhibited the highest mean adhesive tensile bond strengths for all the materials tested, and the 10-minute group exhibited the lowest.

Acrylic Resins↗

Torque required to loosen single-tooth implant abutment screws before and after simulated function.

The amount of torque required to loosen screws from three different antirotational screw-retained abutment/implant combinations was compared (with and without adhesive sealant applied) after 6 kg of force was applied during simulated intraoral movements. Movements were generated over two simulated time periods, representing 1 and 6 months. There was no significant decrease (alpha < .05) in the torque required to loosen the screws after either time period when using Calcitek Omnilock or Stryker Minimatic. The Core-Vent Bio-Vent specimens, however, exhibited a significant decrease (alpha < .05) in the amount of torque required to loosen the screws at the 1-month test period only. The addition of adhesive sealant significantly increased (alpha < .05) the amount of torque necessary to loosen the screws only in the Core-Vent specimens.

Analysis of Variance↗

The effect of custom tray material type and surface treatment on the tensile bond strength of an impression material/adhesive system.

The purpose of this investigation was to evaluate the tensile bond strength of one type of impression material adhesive to three different custom tray materials: one autopolymerizing (Fastray) and two light-polymerizing (Triad and Extoral). The effect of different surface treatments was evaluated for each of the materials. No significant difference in impression material adhesive mean tensile bond strengths was exhibited for any of the materials as the result of variations in the surface treatment. It was observed that the Triad tray material groups, with different surface treatments, exhibited significantly higher impression material adhesive mean tensile bond strengths than the autopolymerizing tray resin and the Extoral light-polymerizing material.

Acrylic Resins↗